Matrix CRM of oil containing cannabinoids METRANAL® CRM AN-BM04

Others | 2022 | ANALYTIKA | UCT PragueInstrumentation
Standards and chemicals
Industries
Food & Agriculture
Manufacturer
ANALYTIKA

Summary

Significance of the topic


Cannabinoid analysis in complex matrices requires well-characterized reference materials to ensure accuracy, reproducibility and compliance with regulatory standards. Certified reference materials (CRMs) for cannabinoids support method validation, instrument calibration and the establishment of metrological traceability to SI units, which is essential for quality assurance in pharmaceutical, food and forensic laboratories.

Objectives and overview


The CRM AN-BM04 consists of MCT oil spiked with hemp extract and individual phytocannabinoids. The certificate documents the preparation, homogeneity, stability and assigned values of selected cannabinoids according to ISO Guide 31. The material is intended to provide a calibration benchmark and transfer of property values to similar matrices.

Methodology


The oil was spiked with a defined hemp extract and pure cannabinoid standards. Homogeneity and short-term stability assessments were performed following ISO Guide 35 in collaboration with an ISO/IEC 17025-accredited laboratory. An international inter-laboratory comparison involving quality-assured analytical laboratories established the overall mean values.

Instrumentation


Recommended analytical techniques involve liquid chromatography using certified calibration standards traceable to SI units. Calibration solutions and/or matrix CRMs of similar composition ensure direct metrological traceability. Specific instrumentation models are not detailed in the certificate but typically include HPLC or UHPLC systems coupled with UV or mass spectrometric detectors.

Main results and discussion


Seven cannabinoids were certified or given indicative status based on the number of accepted laboratory results. Key certified values (mass fraction w/w) with expanded uncertainties (k=2) are:
  • CBD: 5.33 % ± 0.18 %
  • Δ9-THC: 0.1258 % ± 0.0148 %
  • CBDA: 0.0329 % ± 0.0034 %
  • Δ9-THCA-A: 0.0320 % ± 0.0023 %
  • CBN: 0.0736 % ± 0.0027 %
  • CBG: 0.0442 % ± 0.0068 %
  • CBC: 0.0639 % ± 0.0035 %

Minor cannabinoids (CBGA, CBDV, CBCA, THCV, CBL) are reported as indicative values. The dominant uncertainty contribution arises from characterization.

Benefits and practical applications


The CRM AN-BM04 enables:
  • Validation and verification of chromatographic methods for cannabinoid profiling.
  • Calibration of instruments and traceability to SI units.
  • Inter-laboratory comparisons and quality control in pharmaceutical, nutraceutical and regulatory environments.

Future trends and potential uses


Development of matrix-matched CRMs for novel cannabinoids and minor constituents will support emerging research and legal requirements. Advances in high-resolution mass spectrometry and non-targeted screening could drive demand for multi-component CRMs. Digital certification and blockchain-enabled traceability may enhance transparency and data integrity.

Conclusion


CRM AN-BM04 offers a robust, ISO-compliant reference for quantitative cannabinoid analysis. Its demonstrated homogeneity, stability and internationally validated values make it a valuable tool for ensuring analytical accuracy and harmonizing results across laboratories.

References


ISO Guide 31: Reference materials – Contents of certificates and labels
ISO Guide 35: Reference materials – General and statistical principles for certification
ČSN EN ISO/IEC 17025:2018 – General requirements for the competence of testing and calibration laboratories
ČSN EN ISO 17034:2017 – General requirements for the competence of reference material producers

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Matrix CRM of sewage sludge METRANAL® CRM AN-OK01
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
indicative, indicativecertified, certifiedbenzo, benzouncertainty, uncertaintyfluoranthene, fluoranthenemetrological, metrologicalvalues, valuespcb, pcbtraceability, traceabilitypah, pahpyrene, pyreneanthracene, anthraceneeditorial, editorialvalue, valuereference
CRM - Calibration buffer solution for pH measurement pHanal™ CRMpH4001
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmhomogenous, homogenousvalues, valuesindicative, indicativereference, referencedeclared, declaredexpiration, expirationshelf, shelfguarantees, guaranteesguaranteed, guaranteedcertificate, certificateczech, czechrepublic, republicproperly, properlydepartment
CRM Chromium (Cr) -
CRM Chromium (Cr) -
2023|ANALYTIKA|Others
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmchromium, chromiumaqueous, aqueousreference, referenceelectroanalytical, electroanalyticalcalibration, calibrationbellow, bellowastasol, astasoldeclared, declaredexpiration, expirationanalysing, analysingstoring, storinghomogeneous, homogeneousshelf, shelfsolutions
CRM Nickel (Ni) -
CRM Nickel (Ni) -
2022|ANALYTIKA|Others
ANALYTIKA®, spol. s r.o. Khodlova 1297/47, CZ-193 00 Praha 9 – Horní Počernice www.analytika.net Analytika, spol. s r.o., Oddělení RM, výrobce RM č. 7501, akreditovaný ČIA podle ČSN EN ISO 17034:2017 Analytika, spol. s r.o., Department of RM, Reference Materials…
Key words
crm, crmaqueous, aqueouscalibration, calibrationbellow, bellowastasol, astasoldeclared, declaredexpiration, expirationreference, referenceanalysing, analysingstoring, storinghomogeneous, homogeneoussolutions, solutionsshelf, shelfguarantees, guaranteesnickel
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike