Application Robustness of the 6495D Triple Quadrupole LC/MS System for Nonstop Pesticide Analysis in Black Tea Matrix
Applications | 2024 | Agilent TechnologiesInstrumentation
LC/MS, LC/MS/MS, LC/QQQ
IndustriesFood & Agriculture
ManufacturerAgilent Technologies
Key wordsdeposition, dimethoate, robustness, ifunnel, diazinon, atrazine, axis, checkout, checktune, experiment, idl, parameters, instrument, area, vacshield, counts, out, number, mass, matrix, voltage, sensitivity, time, high, system, scan, remained, labelled, performance, acquisition, examination, carried, desolvation, source, injection, effects, peak, nonstop, passed, min, method, robust, tea, anabel, suitable, corrected, charring, fandino, steeped, testing
Similar PDF
Application robustness of the 6495 triple quadrupole LC/MS system for non-stop Pesticide analysis in black tea matrix
2023|Agilent Technologies|Posters
Poster Reprint ASMS 2023 6495 LC/TQ Launch Application robustness of the 6495 triple quadrupole LC/MS system for non-stop Pesticide analysis in black tea matrix Peter Weidner, Patrick Batoon, Behrooz Zekavat, Anabel Fandino Agilent Technologies, Santa Clara, CA Introduction Experimental System…
Key words
pyraclostrobin, pyraclostrobinchecktune, checktunedimethoate, dimethoateatrazine, atrazinetea, teaexperiment, experimentdiazinon, diazinonvacshield, vacshieldrobustness, robustnessinjection, injectionpeak, peakifunnel, ifunnelarea, areasensitivity, sensitivityblack
Robustness of the Agilent Ultivo Triple Quadrupole LC/MS With the ESI Source
2019|Agilent Technologies|Technical notes
Technical Overview Robustness of the Agilent Ultivo Triple Quadrupole LC/MS With the ESI Source 10,000 Injections of pesticides spiked in black tea matrix Figure 1. Ultivo triple quadrupole LC/MS with the Agilent electrospray ion source Abstract This Technical Overview demonstrates…
Key words
ultivo, ultivoacquisition, acquisitionsource, sourcemetoxuron, metoxuronaminocarb, aminocarbion, ionquadrupole, quadrupoletriple, triplecomponents, componentselectrospray, electrospraymin, minacifluorfen, acifluorfentime, timeinstrument, instrumentdeposit
Instrument Detection Limit at Ultrashort Dwell Times Demonstrated on the Agilent 6495C Triple Quadrupole LC/MS
2020|Agilent Technologies|Technical notes
Technical Overview Instrument Detection Limit at Ultrashort Dwell Times Demonstrated on the Agilent 6495C Triple Quadrupole LC/MS Authors Charles Nichols, Behrooz Zekavat, and Patrick Batoon Agilent Technologies, Inc. Abstract This Technical Overview presents the measurement of the instrument detection limit…
Key words
idl, idldwell, dwellinstrument, instrumenttime, timecounts, countsextremely, extremelychromatographic, chromatographicminutes, minutestimes, timesshort, shortacquisition, acquisitionmrm, mrmrsd, rsdion, ionduty
Method for Direct Analysis of Contaminants in Surface Waters With High Accuracy and Precision Using an Agilent 6470A Triple Quadrupole LC/MS System
2016|Agilent Technologies|Applications
Method for Direct Analysis of Contaminants in Surface Waters With High Accuracy and Precision Using an Agilent 6470A Triple Quadrupole LC/MS System Application Note Environmental, Surface Water, Personal Care Products (PPCPs) Authors Abstract Jian-Zhong Li and Craig Marvin Using the…
Key words
bupropion, bupropioncontaminants, contaminantscotinine, cotininedextrorphan, dextrorphansurface, surfaceclarithromycin, clarithromycingemfibrozil, gemfibroziltriclopyr, triclopyrvenlafaxine, venlafaxinetriclosan, triclosangabapentin, gabapentinsucralose, sucraloselamotrigine, lamotriginediltiazem, diltiazemdeet