Alliance iS Bio HPLC TUV Detector
Brochures and specifications | 2024 | WatersInstrumentation
The Alliance iS Bio HPLC TUV Detector enables precise monitoring of biomolecules during biopharmaceutical development and quality control. Its tunable dual-wavelength capability and robust design address the stringent requirements for sensitivity, accuracy, and reproducibility in protein and peptide analysis.
This document presents an overview of the key performance specifications of the Alliance iS Bio HPLC TUV Detector. It highlights the detector’s design features, operating ranges, and practical benefits for challenging bioseparation workflows.
The detector integrates the following elements:
The detector delivers:
These specifications support high-sensitivity detection and reliable quantification of low-concentration analytes in complex matrices.
The Alliance iS Bio detector offers:
Advancements in biopharmaceutical analysis may include:
The Alliance iS Bio HPLC TUV Detector combines high sensitivity, precise wavelength control, and advanced diagnostics to meet the rigorous demands of biopharmaceutical labs. Its robust design and seamless software integration make it a valuable tool for routine quality control and advanced research applications.
The summary is based on the specifications for the Alliance iS Bio HPLC TUV Detector, including its optical, physical, environmental, and electrical characteristics as defined by Waters Corporation.
HPLC
IndustriesOther
ManufacturerWaters
Summary
Importance of UV/Vis Detection in Biopharmaceutical Analysis
The Alliance iS Bio HPLC TUV Detector enables precise monitoring of biomolecules during biopharmaceutical development and quality control. Its tunable dual-wavelength capability and robust design address the stringent requirements for sensitivity, accuracy, and reproducibility in protein and peptide analysis.
Objectives and Article Overview
This document presents an overview of the key performance specifications of the Alliance iS Bio HPLC TUV Detector. It highlights the detector’s design features, operating ranges, and practical benefits for challenging bioseparation workflows.
Methodology and Instrumentation
The detector integrates the following elements:
- Tunable UV/Vis detection from 190 to 700 nm with electronic wavelength control via an Erbium filter.
- TaperSlit™ flow cell and high-brightness lamp, each embedded with Intelligent Chip Technology for automated status reporting in Empower™ CDS.
- Sampling rates up to 160 Hz (single channel) and dual-wavelength acquisition at 1–2 Hz.
- Leak sensors and full diagnostic data for unattended operation.
Main Performance Characteristics and Discussion
The detector delivers:
- Wavelength accuracy within ±1.0 nm and repeatability of ±0.1 nm.
- Bandwidth <5 nm and linearity r² ≥0.999 from 0.0001 to 2 AU, with ≤5% deviation up to 2.5 AU.
- Baseline noise below 5 µAU (single wavelength) and ≤35 µAU (dual wavelength); drift ≤100 µAU/hour.
- Analytical flow cell path length of 10 mm, volume 16.3 µL, and pressure tolerance up to 1000 psi.
These specifications support high-sensitivity detection and reliable quantification of low-concentration analytes in complex matrices.
Benefits and Practical Applications
The Alliance iS Bio detector offers:
- Enhanced stability against temperature and humidity variations, minimizing baseline fluctuations.
- Integration with Empower CDS for streamlined data capture and reporting.
- Versatility across peptide mapping, protein purity assessment, and small-molecule impurity profiling.
- Compact footprint and low power consumption for laboratory efficiency.
Future Trends and Potential Applications
Advancements in biopharmaceutical analysis may include:
- Further miniaturization of flow cells to reduce sample consumption.
- Integration with multi-dimensional separations and mass spectrometry interfaces.
- Enhanced data analytics with AI-driven peak detection and spectral deconvolution.
- Extended wavelength bridges into near-IR for glycan and lipid profiling.
Conclusion
The Alliance iS Bio HPLC TUV Detector combines high sensitivity, precise wavelength control, and advanced diagnostics to meet the rigorous demands of biopharmaceutical labs. Its robust design and seamless software integration make it a valuable tool for routine quality control and advanced research applications.
Instrumentation Used
The summary is based on the specifications for the Alliance iS Bio HPLC TUV Detector, including its optical, physical, environmental, and electrical characteristics as defined by Waters Corporation.
Reference
- All specifications derive from instrument performance after a 1-hour warm-up time.
- U.S. Patent Numbers: 6,423,249 and 6,783,705.
- ASTM E1657.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Alliance iS Bio HPLC System - SPECIFICATIONS
2024|Waters|Brochures and specifications
[ INSTRUMENT SPECIFICATIONS ] Alliance iS Bio HPLC System The Alliance™ iS Bio HPLC System is for applications that ensure uninterrupted supply of safe and effective biotherapeutics. The flow path is designed using biocompatible materials like MP35N and titanium, along…
Key words
specifications, specificationsalliance, alliancerange, rangeoperating, operatingbio, biosynchronization, synchronizationsystem, systempassive, passivewetted, wettedinstrument, instrumentwavelength, wavelengthaccuracy, accuracysolvent, solventtracking, trackingcomposition
Alliance iS Bio HPLC System - INSTRUMENT SPECIFICATIONS
2024|Waters|Brochures and specifications
[ INSTRUMENT SPECIFICATIONS ] Alliance iS Bio HPLC System The Alliance™ iS Bio HPLC System is for applications that ensure uninterrupted supply of safe and effective biotherapeutics. The flow path is designed using biocompatible materials like MP35N and titanium, along…
Key words
specifications, specificationsalliance, alliancewetted, wettedbio, biorange, rangeaccuracy, accuracysystem, systemoperating, operatingsynchronization, synchronizationpassive, passivevolume, volumehplc, hplcwavelength, wavelengthinstrument, instrumenttemperature
Waters Alliance iS HPLC System - INSTRUMENT SPECIFICATIONS
2023|Waters|Brochures and specifications
[ INSTRUMENT SPECIFICATIONS ] Alliance iS HPLC System The Alliance™ iS HPLC System supports FTQ (first-time quality) by reducing the risk of common errors and improving the reliability of analytical measurements. Your lab can reduce reagents and consumables waste, and…
Key words
specifications, specificationsalliance, alliancewetted, wettedrange, rangeaccuracy, accuracysystem, systemcapacity, capacityoperating, operatingsynchronization, synchronizationpassive, passivevolume, volumehplc, hplcwavelength, wavelengthinstrument, instrumentcomposition
Waters Arc Premier 2489 UV/Visible Detector
2021|Waters|Brochures and specifications
[ INSTRUMENT SPECIFICATIONS ] Arc Premier 2489 UV/Visible Detector Whether you are doing routine UV-based applications or pushing the limits of detection with low-level impurity analyses, the Waters™ Arc™ Premier 2489 UV/Visible (UV/Vis) Detector is the best detection choice for…
Key words
specifications, specificationscell, cellinputs, inputswavelength, wavelengthrange, rangeanalytical, analyticaldry, dryflow, flowaudible, audibleoperating, operatingpower, powerbandwidth, bandwidthwetted, wettedoutputs, outputsbiocompatible