Agilent Bravo Automated Liquid Handling Platform: 96-Channel 250 μL Tip Accuracy and Precision

Technical notes | 2024 | Agilent TechnologiesInstrumentation
Sample Preparation
Industries
Other
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


Automated liquid handling accelerates sample processing while maintaining high accuracy and precision, reducing manual errors and improving reproducibility in laboratory workflows.

Objectives and Study Overview


This study evaluates the performance of the Agilent Bravo Automated Liquid Handling Platform equipped with a 96-channel large transfer tip head at dispensing volumes ranging from 2 to 10 µL, focusing on accuracy and precision metrics.

Methodology and Instrumentation


Precision and accuracy were assessed by dispensing tartrazine in DMSO into dry microplates, diluting with water, and measuring absorbance at 405 nm. Key instrumentation included
  • Agilent Bravo with 96-channel LT disposable 250 µL tip head
  • Agilent 96LT 250 µL tips
  • 96-well manual fill reservoir
  • 384-well polystyrene microplates
  • UV/Vis spectrophotometer with 405 nm filter

Results and Discussion


Main findings for the 96LT head at low-volume dispensing:
  • 2 µL: 2.1% CV and ±3.3% accuracy, with 6% outliers at the 5% threshold
  • 5 µL: 1.1% CV and ±0.3% accuracy, no outliers
  • 10 µL: 1.0% CV and ±4.2% accuracy, no outliers
  • Volumes above 10 µL met or exceeded the 10 µL performance metrics
The data confirm consistent precision (under 5% CV) and accuracy within ±10% across the tested range, with transfer times of 22–37 seconds per plate depending on volume.

Benefits and Practical Applications


The Agilent Bravo platform enables high-throughput, automated dispensing across a wide volume range with a single tip head, supporting applications such as compound transfers, genomic assays, and cell-based experiments while minimizing manual intervention and error rates.

Future Trends and Applications


Advancements may include integration with real-time quality control sensors, expanded liquid class libraries for diverse reagent types, and enhanced software-driven optimization to further reduce cycle times and broaden applicability in pharmaceutical, biotechnology, and clinical laboratories.

Conclusion


The 96-channel LT head on the Agilent Bravo Platform delivers reliable and precise low-volume dispensing, meeting stringent accuracy and precision criteria, thus offering a robust solution for automating varied laboratory protocols.

References


  • J. W. Holman, T. E. Mifflin, R. A. Felder, L. M. Demers, Evaluation of an automated preanalytical robotic workstation at two academic health centers, Clin. Chem. 48:540-548, 2002.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent Bravo Automated Liquid Handling Platform: 384-Channel 70 μL Tip Accuracy and Precision
Technical Overview Agilent Bravo Automated Liquid Handling Platform: 384-Channel 70 μL Tip Accuracy and Precision Abstract Automation helps to scale up sample throughput without sacrificing quality. It improves accuracy (the desired dispensed volume is equal to the actual dispensed volume)…
Key words
yes, yesbravo, bravodispensed, dispensedmicroplates, microplatesaccuracy, accuracyprecision, precisionvworks, vworkstartrazine, tartrazineplate, plateautomated, automatedvolume, volumedeck, deckactual, actualdispensing, dispensingdmso
Agilent Bravo Automated Liquid Handling Platform: 96-Channel 10 μL Tip Accuracy and Precision
Technical Overview Agilent Bravo Automated Liquid Handling Platform: 96-Channel 10 μL Tip Accuracy and Precision Abstract Automation helps to scale up sample throughput without sacrificing quality. It improves accuracy (the desired dispensed volume is equal to the actual dispensed volume)…
Key words
yes, yesbravo, bravodispensed, dispensedmicroplates, microplatesprecision, precisionaccuracy, accuracytartrazine, tartrazineautomated, automateddeck, deckliquid, liquidvolume, volumedmso, dmsohandling, handlingvariance, varianceoverview
Agilent Bravo Automated Liquid Handling Platform: 384-Channel 30 μL Tip Accuracy and Precision
Technical Overview Agilent Bravo Automated Liquid Handling Platform: 384-Channel 30 μL Tip Accuracy and Precision Abstract Automation helps to scale up sample throughput without sacrificing quality. It improves accuracy (the desired dispensed volume is equal to the actual dispensed volume)…
Key words
yes, yesbravo, bravodispensed, dispensedmicroplates, microplatesaccuracy, accuracyprecision, precisionvworks, vworkstartrazine, tartrazineautomated, automatedvolume, volumedeck, deckdispensing, dispensingplate, platedmso, dmsohandling
Agilent Bravo Automated Liquid Handling Platform: 384-Channel 10 μL Tip Accuracy and Precision
Technical Overview Agilent Bravo Automated Liquid Handling Platform: 384-Channel 10 μL Tip Accuracy and Precision Abstract Automation helps to scale up sample throughput without sacrificing quality. It improves accuracy (the desired dispensed volume is equal to the actual dispensed volume)…
Key words
yes, yesbravo, bravodispensed, dispensedmicroplates, microplatesprecision, precisionaccuracy, accuracyautomated, automatedtartrazine, tartrazineliquid, liquiddispensing, dispensingvolume, volumedmso, dmsohandling, handlingoverview, overviewdisposable
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike