LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Separation of sugars on Primesep S column

Applications | 2007 | SIELCInstrumentation
Consumables, HPLC, LC columns
Industries
Food & Agriculture
Manufacturer
SIELC

Summary

Significance of the Topic


High-performance separation of carbohydrates is critical in food quality control, pharmaceuticals and biochemical research. Sugars lack strong UV chromophores, making evaporative light scattering detection (ELSD) combined with mixed-mode stationary phases a valuable approach for sensitive and selective analysis.

Objectives and Study Overview


This application note demonstrates the resolution of five common sugars—sorbitol, sucrose, α-D-lactose, β-D-lactose and raffinose—using a mixed-mode Primesep S column with ELSD detection under isocratic conditions.

Methodology and Instrumentation


Used Instrumentation:
  • Column: Primesep S, 4.6 × 150 mm
  • Mobile Phase: Acetonitrile/water (80/20, v/v)
  • Flow Rate: 1.0 mL/min
  • Detection: ELSD at 45 °C

Samples were injected under isocratic conditions. ELSD settings were optimized for carbohydrate sensitivity.

Main Results and Discussion


The chromatogram achieved baseline separation of all five analytes within 30 minutes. Sorbitol eluted first, followed by sucrose, α-D-lactose, β-D-lactose and raffinose. Peak shapes were sharp and symmetric, indicating strong interaction with ion-exchange and reversed-phase sites on the Primesep S resin. ELSD response provided consistent sensitivity across compounds.

Benefits and Practical Applications


  • Rapid, reliable sugar profiling for food and botanical samples
  • Non-UV detection suitable for non-chromophoric analytes
  • Robust mixed-mode separation reducing need for gradient optimization

Future Trends and Potential Applications


Emerging directions include coupling ELSD methods with mass spectrometry for structural elucidation, miniaturized columns for high-throughput screening and development of stationary phases tailored for novel carbohydrate isomers. Advances in detector sensitivity and gradient optimization will further enhance throughput and resolution.

Conclusion


The Primesep S column with ELSD detection offers an efficient, isocratic method for comprehensive separation of common sugars. Its simplicity and robustness make it an attractive choice for routine carbohydrate analysis in quality control and research laboratories.

Reference


No literature references were cited in the original document.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
HPLC Columns for Simultaneous Analysis of Counter-Ions
July 2009 Newsletter HPLC Columns for Simultaneous Analysis of Counter-Ions SIELC Technologies, Inc., Prospect Heights, IL 60070 Majority of the drugs are produced in a salt form. The counter ions in drugs can be inorganic and organic, acidic or basic.…
Key words
obelisc, obelisccounter, countermodal, modalprimesep, primesepacid, aciddrug, drugmin, minion, iondextromethorphan, dextromethorphanbasic, basicacidic, acidicmaleate, maleatetrimipramine, trimipraminepseudoephedrine, pseudoephedrinechlorpheniramine
Easy HPLC Method Development
Easy HPLC Method Development
2010|SIELC|Technical notes
May 2010 Newsletter Easy HPLC Method Development Sometimes method development in chromatography can be a challenging and time consuming task. Screening multiple columns and different mobile phases is frustrating, in many cases requiring purchases of different columns. And what happens…
Key words
primesep, primesepobelisc, obeliscmethod, methodmin, mincomplex, complexacetaminophen, acetaminophencan, canuplc, uplccolumns, columnstfa, tfapairs, pairsmethods, methodscomposition, compositionpairing, pairingpanthothenic
Retention of Taurine
Retention of Taurine
2004|SIELC|Applications
Retention of Taurine SIELC Technologies, Inc. 15 E. Palatine Rd. Suite 107, Prospect Heights, IL 60070. Ph 847/229-2629, Fax 847/655-6079, [email protected] Taurine is zwitterionic molecule which posses no charge to be retained by ion-exchange mechanism. The molecule is very polar…
Key words
primesep, primesepdifference, differencemecn, mecntaurine, taurinesmall, smalldissolution, dissolutionretention, retentionpolar, polarincludes, includesdilution, dilutionstructure, structuretypically, typicallygroup, groupobserved, observedfollowing
The Do’s and Don’ts of Method Development in Mixed-Mode Chromatography Part 1. Reversed-Phase Ion-Exchange Columns
August 2009 Newsletter The Do’s and Don’ts of Method Development in Mixed-Mode Chromatography Part 1. Reversed-Phase Ion-Exchange Columns SIELC Technologies, Inc., Prospect Heights, IL 60070 If a reversed-phase chromatography column does not work for your separation, it is most likely…
Key words
primesep, primesepstrength, strengthcolumn, columndon’ts, don’tselsd, elsdequilibration, equilibrationtry, trymin, minbuffer, bufferparaben, parabenproblem, problemcompounds, compoundsmixed, mixedphase, phasemobile
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike