Application of a novel screening workflow for the detection of illicit and medicinal drugs in human hair
Posters | 2024 | Shimadzu | ASMSInstrumentation
Hair analysis extends the detection window of drug intake from days to months, providing invaluable information for forensic toxicology, clinical monitoring, occupational health and anti‐doping control. By capturing long‐term exposure profiles, hair screening reveals patterns of illicit and medicinal drug use that cannot be discerned from blood or urine testing.
This work evaluates a novel non‐targeted screening workflow combining high‐resolution quadrupole time‐of‐flight LC–DIA–MS/MS with an advanced component detection algorithm in Insight Discovery software. The primary goals were to detect single and multiple drug use in human hair extracts with high confidence, automate data processing, and demonstrate the ability to identify both known and unexpected analytes.
An untargeted LC–DIA–MS/MS method was developed for hair extracts:
In a batch of 24 hair samples, the workflow detected 3 384 chromatographic components and screened them against a forensic toxicology library of over 1 200 compounds. Key findings included:
The high‐resolution DIA–MS/MS approach delivered library‐searchable spectra despite sample complexity, and formula prediction provided additional confirmation for unknown components.
The automated Insight Discovery workflow enables rapid, reproducible non‐targeted screening of hair samples with minimal manual intervention. High reporting confidence, combined with formula prediction, supports forensic casework, clinical toxicology assessments and compliance testing in workplace and sports settings.
Advances in spectral libraries, machine learning–driven component detection and cloud‐based data processing will further enhance sensitivity and throughput. Expanding suspect screening to emerging psychoactive substances and integrating quantitative capabilities may broaden applications to environmental monitoring and personalized medicine.
The integration of high‐resolution LC–DIA–MS/MS with Insight Discovery software provides a robust, automated non‐targeted screening platform for detecting illicit and medicinal drugs in human hair. The method achieved reliable identification of single and polydrug use, demonstrating its utility for forensic and clinical laboratories.
LC/HRMS, LC/MS, LC/MS/MS, LC/TOF
IndustriesForensics
ManufacturerShimadzu
Summary
Significance of the Topic
Hair analysis extends the detection window of drug intake from days to months, providing invaluable information for forensic toxicology, clinical monitoring, occupational health and anti‐doping control. By capturing long‐term exposure profiles, hair screening reveals patterns of illicit and medicinal drug use that cannot be discerned from blood or urine testing.
Objectives and Study Overview
This work evaluates a novel non‐targeted screening workflow combining high‐resolution quadrupole time‐of‐flight LC–DIA–MS/MS with an advanced component detection algorithm in Insight Discovery software. The primary goals were to detect single and multiple drug use in human hair extracts with high confidence, automate data processing, and demonstrate the ability to identify both known and unexpected analytes.
Methodology
An untargeted LC–DIA–MS/MS method was developed for hair extracts:
- Chromatography: Shim-pack Velox Biphenyl column (2.1 × 100 mm, 2.7 µm) at 40 °C, 17 min gradient; mobile phases water and methanol, each with 2 mM ammonium formate and 0.002 % formic acid.
- Mass spectrometry: Shimadzu LCMS-9030 QTOF in positive ESI; TOF MS scan m/z 100–1000 (100 ms), 17 DIA MS/MS scans (m/z 40–500, 25 Da isolation, 40 ms) and 12 DIA MS/MS scans (m/z 40–900, 35 Da, 25 ms) with 5–55 V collision energy spread; external mass calibration.
- Data processing: Insight Discovery research application was used for second‐generation untargeted component detection, MS/MS library matching, suspect screening and formula prediction in batch mode.
Applied Instrumentation
- Shimadzu LCMS-9030 high‐resolution QTOF mass spectrometer
- Shim-pack Velox Biphenyl UHPLC column
- Insight Discovery software within LabSolutions Insight
Main Results and Discussion
In a batch of 24 hair samples, the workflow detected 3 384 chromatographic components and screened them against a forensic toxicology library of over 1 200 compounds. Key findings included:
- Four samples positive for cocaine and its primary metabolite benzoylecgonine; two samples contained low levels of codeine.
- Widespread detection of caffeine, nicotine and DEET as common co‐analytes.
- Identification of polydrug markers such as cocaethylene, ecgonine methyl ester, levamisole, MDMA, sildenafil and quinine.
- Thirteen precursor matches at user-defined low thresholds; eleven targets confirmed by high‐confidence MS/MS library matching.
The high‐resolution DIA–MS/MS approach delivered library‐searchable spectra despite sample complexity, and formula prediction provided additional confirmation for unknown components.
Benefits and Practical Applications
The automated Insight Discovery workflow enables rapid, reproducible non‐targeted screening of hair samples with minimal manual intervention. High reporting confidence, combined with formula prediction, supports forensic casework, clinical toxicology assessments and compliance testing in workplace and sports settings.
Future Trends and Possibilities
Advances in spectral libraries, machine learning–driven component detection and cloud‐based data processing will further enhance sensitivity and throughput. Expanding suspect screening to emerging psychoactive substances and integrating quantitative capabilities may broaden applications to environmental monitoring and personalized medicine.
Conclusion
The integration of high‐resolution LC–DIA–MS/MS with Insight Discovery software provides a robust, automated non‐targeted screening platform for detecting illicit and medicinal drugs in human hair. The method achieved reliable identification of single and polydrug use, demonstrating its utility for forensic and clinical laboratories.
Reference
- Armitage EG, Brema T, Bowen CA, Barnes NJ, Steel R, Loftus L. Application of a novel screening workflow for the detection of illicit and medicinal drugs in human hair. Shimadzu White Paper, 2023.
- Shimadzu High Resolution Accurate Mass Library for Forensic Toxicology.
- HighResNPS library (https://highresnps.com/).
- Wiley Registry of Tandem Mass Spectral Data: MS for ID.
- Maurer/Meyer/Helfer/Weber LC–HR–MS/MS Library of Drugs, Poisons, and Their Metabolites.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Seamless automated sample preparation and analysis of DUID samples using high-resolution DIA QTOF library screening
2022|Shimadzu|Posters
Seamless automated sample preparation and analysis of DUID samples using high-resolution DIA QTOF library screening 1 Zarrouk ; 2 Barnes ; 3 Moreau ; 2 Loftus ; Elies Alan Stephane Neil Sylvain Souleiman El Franck 1CHU Limoges, Limoges, France; 2Shimadzu…
Key words
oral, oralfluid, fluidduid, duidlibrary, librarybenzoylecgonine, benzoylecgoninepatient, patientcocaine, cocainecao, caohouse, houseautomated, automatedmethylester, methylesterpanel, panelecgonine, ecgoninepreparation, preparationspectrum
Highly-Efficient Screening Approach for Toxicological Compounds in Human Blood Samples on LCMS-9030
2022|Shimadzu|Applications
High Performance Liquid Chromatograph Mass Spectrometer LCMS-9030 Application News Highly-Efficient Screening Approach for Toxicological Compounds in Human Blood Samples on LCMS-9030 Zhaoqi Zhan1, Nat Tansrisawad2, Apinya Tubtimrattana3, Chukkapong Comsup4 Shimadzu Asia Pacific, Singapore, 2 Department of Forensic Medicine, Chulalongkorn University,…
Key words
dia, diauntargeted, untargetedefficient, efficientscreening, screeningsearch, searchlibrary, librarytoxicological, toxicologicalanalyze, analyzedata, datadda, ddaassign, assignconfirm, confirmunknown, unknowntargeted, targetedhrms
SOFT: Toxicology Screening of Human Blood using Quadrupole-Time of Flight (QTOF) Mass Spectrometry
2023|Shimadzu|Posters
P-79 Toxicology Screening of Human Blood using Quadrupole-Time of Flight (QTOF) Mass Spectrometry Evelyn H. Wang1; Neil J Loftus2; Jennifer Davis1; Rachel Lieberman1; Christopher T Gilles1 1Shimadzu Scientific Instruments, Columbia, MD; 2Shimadzu MS/BU, Manchester, United Kingdom Overview Results and Discussion…
Key words
library, librarypositive, positiveblood, bloodmethamphetami, methamphetamitoxicology, toxicologymethamphetamine, methamphetaminespectrum, spectrumabused, abusedgabapentin, gabapentinsample, samplefluoxetine, fluoxetinescreening, screeningpos, posneg, negbenzoylecgonine
Automating component detection of small molecules in complex mixtures using HRAM Q-TOF data
2019|Shimadzu|Posters
PO-CON1886E Automating component detection of small molecules in complex mixtures using HRAM Q-TOF data ASMS 2019 Simon Ashton1; Kirsten Hobby1; Alan Barnes1; Neil Loftus1 1 Shimadzu Corporation, Manchester, United Kingdom Automating component detection of small molecules in complex mixtures using…
Key words
hram, hramcomponent, componentmixtures, mixturesautomating, automatingcomplex, complextof, tofdoa, doadetection, detectionalgorithm, algorithmmolecules, moleculessmall, smalldata, datadia, diascreening, screeningapplied