Agilent 1290 Infinity III Ultra Low Dispersion Kit
Manuals | 2024 | Agilent TechnologiesInstrumentation
The Agilent 1290 Infinity III Ultra Low Dispersion (ULD) Kit and its Bio variant enable significant reduction of extra column volume in high-performance liquid chromatography (HPLC) systems by employing narrow-bore capillaries (0.075 mm i.d.). Lowering dispersion improves chromatographic efficiency and sensitivity, particularly for early-eluting peaks and microbore applications.
This technical note outlines the installation procedure for the Agilent 1290 Infinity III ULD Kit (5067-5963) and the 1290 Infinity III Bio ULD Kit (5004-0007). The document provides a step-by-step guide to fitting high-pressure needle seats, heat exchangers, and capillary connections to maximize system performance with 2.1 mm and smaller columns.
The installation workflow includes:
The key components employed during installation include:
Implementing the ULD Kit reduces extra column volume, leading to sharper peak shapes and decreased band broadening. The use of 0.075 mm capillaries enhances resolution for isocratic and gradient separations on 2.1 mm columns, and supports ultra-high pressure applications. However, pressure increases of approximately 165 bar at 1 mL/min must be managed by selecting appropriate flow rates.
The optimized ULD configuration offers:
Advances in microfluidics and sub-2 µm particle columns will further drive demand for ultra-low dispersion systems. Integration with high-resolution mass spectrometry, automated method optimization, and real-time data analytics will expand the role of ULD kits in pharmaceutical, biotech, and environmental laboratories.
The Agilent 1290 Infinity III ULD and Bio ULD Kits deliver a straightforward upgrade path to minimize extra column volume and maximize chromatographic performance. Proper installation and parameter selection ensure reliable, high-resolution separations for demanding analytical applications.
No literature references were provided in the original document.
HPLC
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
The Agilent 1290 Infinity III Ultra Low Dispersion (ULD) Kit and its Bio variant enable significant reduction of extra column volume in high-performance liquid chromatography (HPLC) systems by employing narrow-bore capillaries (0.075 mm i.d.). Lowering dispersion improves chromatographic efficiency and sensitivity, particularly for early-eluting peaks and microbore applications.
Study Objectives and Overview
This technical note outlines the installation procedure for the Agilent 1290 Infinity III ULD Kit (5067-5963) and the 1290 Infinity III Bio ULD Kit (5004-0007). The document provides a step-by-step guide to fitting high-pressure needle seats, heat exchangers, and capillary connections to maximize system performance with 2.1 mm and smaller columns.
Methodology and Instrumentation
The installation workflow includes:
- Preparation: stopping solvent flow, placing modules in service position, and wearing appropriate protective equipment.
- High-Pressure Needle Seat Assembly: removal of the existing seat and insertion of the 0.075 mm PEEK seat for both standard and Bio systems.
- Heat Exchanger Assembly: mounting the Quick Connect Heat Exchanger in the MCT heater block and routing the 500 mm and 105 mm capillaries.
- Column Connection: linking the heat exchanger outlet to the analytical column and detector flow cell using Quick Connect and Quick Turn fittings.
Instrumentation Used
The key components employed during installation include:
- Agilent 1290 Infinity III LC System and 1290 Infinity III Bio LC System
- Ultra Low Dispersion Kit (p/n 5067-5963) and Bio ULD Kit (p/n 5004-0007)
- Capillaries: stainless steel and MP35N, 0.075 mm i.d., in lengths of 105 mm, 250 mm, and 500 mm
- Quick Connect and Quick Turn Fittings, Heat Exchanger modules, High Pressure Seat Assemblies
- Installation tools: open-end wrenches, hex drivers, fitting mounting tool, screwdriver
Main Results and Discussion
Implementing the ULD Kit reduces extra column volume, leading to sharper peak shapes and decreased band broadening. The use of 0.075 mm capillaries enhances resolution for isocratic and gradient separations on 2.1 mm columns, and supports ultra-high pressure applications. However, pressure increases of approximately 165 bar at 1 mL/min must be managed by selecting appropriate flow rates.
Benefits and Practical Applications
The optimized ULD configuration offers:
- Improved chromatographic efficiency and sensitivity
- Enhanced performance for early-eluting compounds in proteomics and small molecule analysis
- Compatibility with narrow-bore and fast UHPLC methods
- Streamlined integration into existing Agilent 1290 workflows
Future Trends and Potential Applications
Advances in microfluidics and sub-2 µm particle columns will further drive demand for ultra-low dispersion systems. Integration with high-resolution mass spectrometry, automated method optimization, and real-time data analytics will expand the role of ULD kits in pharmaceutical, biotech, and environmental laboratories.
Conclusion
The Agilent 1290 Infinity III ULD and Bio ULD Kits deliver a straightforward upgrade path to minimize extra column volume and maximize chromatographic performance. Proper installation and parameter selection ensure reliable, high-resolution separations for demanding analytical applications.
References
No literature references were provided in the original document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
1260 Infinity II Low Dispersion Kit - Technical Note
2021|Agilent Technologies|Manuals
1260 Infinity II Low Dispersion Kit Technical Note This note describes how to install the 1260 Infinity II Low Dispersion Kit (G7111-68708) and 1260 Infinity II Bio Low Dispersion Kit (G7131-68708). Delivery Checklist Installation 2 3 Install the Heat Exchanger…
Key words
exchanger, exchangerheat, heatquick, quickfitting, fittinginstallation, installationconnect, connectparts, partsdescription, descriptionbio, biochecklist, checklistsleeves, sleevesintermediate, intermediateinfinitylab, infinitylabturn, turninstall
The Basics of UV-Vis-NIR Spectrophotometry
2024|Agilent Technologies|Guides
LC Capillaries and Fittings Golnar Javadi Applications Engineer Chemistries and Supplies Technical Support December 12, 2024 1 December 12, 2024 DE-003199 Agenda • Why is it important to use the right connecting capillaries? • Dispersion contribution from capillaries and fittings…
Key words
fittings, fittingscapillaries, capillariesfitting, fittingquick, quickdad, dadpump, pumpinfinitylab, infinitylabturn, turncompartment, compartmentbottle, bottlepeek, peekcolumn, columnconnect, connectdispersion, dispersionsocket
Size Exclusion Chromatography of Biomolecules: Column Selection and Method Optimization
2025|Agilent Technologies|Presentations
LC Capillaries and Fittings Golnar Javadi Applications Engineer Chemistries and Supplies Technical Support December 12, 2024 1 December 12, 2024 DE-003199 Agenda • Why is it important to use the right connecting capillaries? • Dispersion contribution from capillaries and fittings…
Key words
fittings, fittingscapillaries, capillariesfitting, fittingquick, quickdad, dadpump, pumpinfinitylab, infinitylabturn, turncompartment, compartmentbottle, bottlepeek, peekcolumn, columnconnect, connectdispersion, dispersionsocket
LC Capillaries and Fittings
2024|Agilent Technologies|Presentations
LC Capillaries and Fittings Golnar Javadi Applications Engineer Chemistries and Supplies Technical Support December 12, 2024 1 December 12, 2024 DE-003199 Agenda • Why is it important to use the right connecting capillaries? • Dispersion contribution from capillaries and fittings…
Key words
fittings, fittingscapillaries, capillariesfitting, fittingquick, quickdad, dadpump, pumpinfinitylab, infinitylabturn, turncompartment, compartmentbottle, bottlepeek, peekcolumn, columnconnect, connectdispersion, dispersionsocket