DECADE™ Elite Electrochemical detector
Brochures and specifications | | Watrex PragueInstrumentation
Electrochemical detection in high performance liquid chromatography offers unmatched sensitivity and selectivity for electroactive compounds compared to optical and aerosol detectors. It enables quantification at femtogram levels, requires minimal sample volume, and effectively minimizes matrix interferences, making it ideal for trace analysis in complex matrices and applications in neuroscience, pharmaceuticals, food quality, and clinical diagnostics.
This summary reviews the DECADE Elite electrochemical detector, highlighting its design features, performance improvements, and application spectrum. The goal is to illustrate how advanced electronics, temperature control, and specialized flow cells contribute to enhanced signal-to-noise ratio and method flexibility across various fields.
The DECADE Elite detector integrates high-quality electronics for ≤2 pA noise, a Faraday‐shielded oven for 0.1 °C temperature stability, and an Advanced Digital Filter (ADF) to suppress high-frequency noise, improving S/N up to 100×. Two flow cell options are available: SenCell™ wall-jet cell for maximum sensitivity and FlexCell™ for modular electrode replacement. The system supports single or dual cell control, networked PC operation, and is compatible with major chromatography data systems.
Electrochemical detection with the DECADE Elite provides a robust, highly sensitive, and versatile solution for trace analysis in HPLC and UHPLC workflows. Its advanced electronics, precise temperature control, specialized flow cells, and digital filtering deliver superior performance across diverse analytical fields, establishing it as a detector of choice for demanding applications.
HPLC
IndustriesFood & Agriculture, Pharma & Biopharma
ManufacturerOther
Summary
Importance of the topic
Electrochemical detection in high performance liquid chromatography offers unmatched sensitivity and selectivity for electroactive compounds compared to optical and aerosol detectors. It enables quantification at femtogram levels, requires minimal sample volume, and effectively minimizes matrix interferences, making it ideal for trace analysis in complex matrices and applications in neuroscience, pharmaceuticals, food quality, and clinical diagnostics.
Objectives and study overview
This summary reviews the DECADE Elite electrochemical detector, highlighting its design features, performance improvements, and application spectrum. The goal is to illustrate how advanced electronics, temperature control, and specialized flow cells contribute to enhanced signal-to-noise ratio and method flexibility across various fields.
Methodology
- Principle: Direct measurement of analytes via oxidation or reduction at a working electrode.
- Operation modes: DC amperometry for high-sensitivity assays, pulsed amperometric detection (PAD) for carbohydrates and antibiotics, and scanning voltammetry for method development.
- Parameters controlling selectivity: applied potential, electrode material (glassy carbon, Au, Ag, Pt, boron-doped diamond), mobile phase composition (pH, ion strength, ion-pair agents), and enzymatic or chemical pre-activation.
Used instrumentation
The DECADE Elite detector integrates high-quality electronics for ≤2 pA noise, a Faraday‐shielded oven for 0.1 °C temperature stability, and an Advanced Digital Filter (ADF) to suppress high-frequency noise, improving S/N up to 100×. Two flow cell options are available: SenCell™ wall-jet cell for maximum sensitivity and FlexCell™ for modular electrode replacement. The system supports single or dual cell control, networked PC operation, and is compatible with major chromatography data systems.
Main results and discussion
- Noise performance: ≤2 pA baseline noise with dummy cell in the 1 nA range and ADF off.
- Temperature control: Faraday‐shielded oven yields stable baselines, eliminating drift evidenced by comparison chromatograms.
- Signal enhancement: ADF low-pass filter selectively attenuates noise while preserving chromatographic peaks, enabling significant S/N gains.
- Detection limits: Achievable on-column limits in the femtogram range for neurotransmitters and sub-fmol detection for monoamines in microdialysates.
Benefits and practical applications
- Neuroscience: Quantification of neurotransmitters and metabolites in microdialysates and CSF at sub-100 pmol/L concentrations.
- Antibiotics: Compliance with pharmacopeia standards for aminoglycoside and macrolide analysis, including impurity profiling.
- Clinical diagnostics: Rapid assays for catecholamines, metanephrines, and PET tracer purity ([18F]FDG) by HPAEC-PAD.
- Food and beverage: Determination of carbohydrates, lactose in dairy, phenols, and polyphenols fulfilling labeling requirements.
- Other analytes: Amino acids, thiols/disulfides, vitamins, iodide, and pharmaceutical QC with high sensitivity and selectivity.
Future trends and potential applications
- Emerging electrode materials and nanostructuring to further lower detection limits.
- Integration of microfluidic platforms for on-chip sample preparation and multiplexed analyses.
- Coupling with mass spectrometry for complementary detection and structural characterization.
- Development of portable and field‐deployable electrochemical detectors for on-site testing.
- Implementation of AI-driven method optimization for automated parameter selection and enhanced throughput.
Conclusion
Electrochemical detection with the DECADE Elite provides a robust, highly sensitive, and versatile solution for trace analysis in HPLC and UHPLC workflows. Its advanced electronics, precise temperature control, specialized flow cells, and digital filtering deliver superior performance across diverse analytical fields, establishing it as a detector of choice for demanding applications.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
ALEXYS™ Carbohydrate Analyzer
|Other|Brochures and specifications
ALEXYS™ Carbohydrate Analyzer Dedicated high-performance anion exchange chromatography system with pulsed amperometric detection (HPAEC-PAD) for precise and reliable carbohydrate analysis. n S uperior separation - paired with SweetSep™ column n O utstanding sensitivity no need for derivatisation or…
Key words
alexys, alexyssweetsep, sweetsepcarbohydrate, carbohydrateantec, antecglucose, glucoseanalyzer, analyzerelectrochemical, electrochemicalsencell, sencellfructose, fructosesialylated, sialylatedflow, flowcurrent, currentmaltose, maltosehpaec, hpaeclactose
Clarity Control Module ANTEC DECADE ELITE
2024|DataApex|Manuals
ANTEC DECADE ELITE Clarity Control Module ENG Code/Rev.: M179/90B Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex®…
Key words
antec, antecdecade, decadeelite, elitettl, ttloutput, outputinput, inputoutputs, outputsdetector, detectortimestamps, timestampsdialog, dialogclarity, clarityrelay, relaydigital, digitalset, setinputs
ROXY™ Exceed Electrochemistry System for EC-MS
|Other|Brochures and specifications
ROXY™ Exceed Electrochemistry System for EC-MS Proteomics Metabolism Drug Stability Environmental Synthesis Electrochemistry – Mass Spectrometry (EC–MS) Why? Over 90% of the worlds existing compounds possess REDOX properties, making them either oxidizable or reducible. By injecting your analyte into an…
Key words
roxy, roxyexceed, exceedantec, antecreduction, reductionelectrochemistry, electrochemistryreactorcell, reactorcellsynthesiscell, synthesiscelldegradation, degradationinter, interdrug, druginfusion, infusionchain, chainsyringe, syringeelectroactive, electroactivebonds
Clarity Control Module ANTEC DECADE II
2024|DataApex|Manuals
ANTEC DECADE II Clarity Control Module ENG Code/Rev.: M114/90B Date: 2024-11-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex®…
Key words
antec, antecdecade, decadeoutputs, outputstimestamps, timestampsdetector, detectorelectric, electricdialog, dialogdigital, digitalvalve, valveclarity, clarityttl, ttlsignal, signalinputs, inputssetup, setupout