LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Chiral separation of Warfarin (4-Hydroxy-3-(3-Oxo-1-Phenyl-Butyl)- Cumarin)

Applications |  | KNAUERInstrumentation
Consumables, LC columns, HPLC
Industries
Manufacturer
KNAUER

Summary

Importance of the Topic


The resolution of warfarin enantiomers is critical due to differences in pharmacological activity and safety between its mirror-image forms. Effective chiral separation ensures accurate potency assessment, reduces adverse effects, and supports regulatory compliance in pharmaceutical analysis.

Objectives and Overview of the Study


This study evaluates the performance of a cellulose-based Eurocel 01 column for the enantioselective HPLC separation of warfarin. Key aims include optimizing chromatographic conditions, assessing resolution parameters, and establishing a reliable method for routine quality control.

Methodology and Instrumentation


A reversed-phase chiral HPLC method was employed using:
  • Column: Eurocel 01, 5 µm, 250×4.6 mm ID
  • Mobile phase: Acetonitrile/water (50:50) with 0.1% trifluoroacetic acid
  • Flow rate: 1.0 mL/min
  • Temperature: 25 °C
  • Injection volume: 10 µL
  • Detection: UV at 270 nm

Key Results and Discussion


Under isocratic conditions, two enantiomers of warfarin were successfully separated with retention factors k′_1=2.88 and k′_2=4.39, yielding a selectivity factor (α) of 1.53. The chromatogram demonstrated baseline separation within 18 minutes. Cellulose-based Eurocel 01 provided distinct enantioselectivity attributed to reversible interactions between the analyte and chiral selector.

Benefits and Practical Applications


  • Robust enantiomeric resolution suitable for routine QC laboratories
  • Reproducible retention times and selectivity for batch-to-batch consistency
  • Minimal method development effort due to isocratic operation
  • Applicability to pharmaceutical formulation testing and impurity profiling

Future Trends and Potential Applications


Advances may include coupling with mass spectrometry for enhanced sensitivity, exploring alternative mobile phases to improve resolution, and adapting the method for high-throughput screening in drug discovery.

Conclusion


The study confirms that Eurocel 01 chiral HPLC provides an efficient, precise, and reproducible approach for separating warfarin enantiomers, fulfilling pharmaceutical quality requirements and paving the way for extended analytical applications.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Chiral separation of Atenolol (2-[4-[2-Hydroxy-3- (1-Methylethylamino)Propoxy]Phenyl]Ethanamid)
Chiral separation of Atenolol (2-[4-[2-Hydroxy-3(1-Methylethylamino)Propoxy]Phenyl]Ethanamid) Method HPLC VCR0008J Chiral HPLC Column: Eurocel 01 5 µm, 250 x 4.6 mm ID Phase: Eurocel 01, 5 µm Conditions: Eluent: Gradient: Flow rate: Temperature: Volume: Detection: UV at 230 nm Substances: Atenolol (2-[4-[2-Hydroxy-3-(1-Methylethylamino)Propoxy]Phenyl]Ethanamid)…
Key words
hplc, hplcchiral, chiralisocratic, isocraticmethod
Chiral separation of Etozolin (Ethyl(3-Methyl-4-Oxo-5- Piperidinothiazolidin-2-ylidene)Acetate)
Chiral separation of Etozolin (Ethyl(3-Methyl-4-Oxo-5Piperidinothiazolidin-2-ylidene)Acetate) Method HPLC VCR0028J Chiral HPLC Column: Eurocel 01 5 µm, 250 x 4.6 mm ID Phase: Eurocel 01, 5 µm Conditions: Eluent: Gradient: Flow rate: Temperature: Volume: Detection: UV at 220 nm Substances: Etozolin (Ethyl(3-Methyl-4-Oxo-5-Piperidinothiazolidin-2-ylidene)Acetate)…
Key words
hplc, hplcchiral, chiralisocratic, isocraticmethanol, methanolmethod
Chiral separation of Benzyl-Mandelate (Benzyl-2-Hydroxy-3- Phenylpropionate)
Chiral separation of Benzyl-Mandelate (Benzyl-2-Hydroxy-3Phenylpropionate) Method HPLC VCR0014J Chiral HPLC Column: Eurocel 01 5 µm, 250 x 4.6 mm ID Phase: Eurocel 01, 5 µm Conditions: Eluent: Gradient: Flow rate: Temperature: Volume: Detection: UV at 210 nm Substances: Benzyl-Mandelate (Benzyl-2-Hydroxy-3-Phenylpropionate)…
Key words
hplc, hplcchiral, chiralisocratic, isocraticminutes, minutesmethod
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike