Summary

Significance of the topic


Automated sample introduction is a cornerstone of high-performance chromatography workflows. The Spark Holland Triathlon autosampler control module expands laboratory throughput and reproducibility by providing precise, programmable handling of vials, syringes and valves. Integration with the Clarity chromatography station offers seamless method management, data acquisition and reporting in regulated and research-driven environments.

Study Objectives and Overview


This application note outlines the configuration, method development and operation of the Spark Triathlon control module within Clarity software. Key goals include:
  • Establishing hardware and communication requirements
  • Detailing software setup in Clarity System Configuration
  • Explaining method parameters for injection, wash, timebase, mixing and user-programmed sequences
  • Presenting monitoring, troubleshooting and reporting capabilities

Methodology and Instrumentation


This solution requires a Windows-based PC running Clarity with the AS control module installed and a free RS-232 COM port (or MultiCOM adapter). A straight DB9F-DB9M cable connects PC and autosampler. In Clarity, the Spark Triathlon driver is added via System Configuration and mapped to an instrument tab. Method Setup menus include Injection & Wash, Timebase outputs, Mix programming, User Program table, System parameters (syringe volume, speed, tray cooling, needle height) and Vial/Tray assignments.

Main Results and Discussion


Configuration enables:
  • Full or partial loop injection, micro-pick-up mode and timed syringe operations
  • Programmable wash cycles between injections, samples or series
  • Timebase-driven activation of auxiliary outputs, solvent selection valves and stream switching
  • Complex mixing routines with aspirate, dispense, repeat and wait commands
  • User-defined command sequences for advanced control
Real-time Device Monitor functions support manual syringe and valve movements, initial wash and tray advance. Debug logging via COMMDRV.INI facilitates rapid troubleshooting.

Benefits and Practical Applications


Precise autosampler control reduces carry-over and improves data consistency. Flexible method programming adapts to diverse analytical needs, from routine QA/QC to complex sample pre- or post-column derivatization. Seamless reporting captures all autosampler parameters alongside chromatographic results.

Future Trends and Potential Applications


Next-generation developments may include:
  • Cloud-enabled LIMS integration and remote monitoring
  • AI-driven method optimization and adaptive sampling
  • Miniaturized flow paths for ultra-low volume sampling
  • Modular add-ons for multi-dimensional chromatography

Conclusion


The Spark Holland Triathlon control module, when integrated with Clarity, delivers robust, customizable autosampler management. It streamlines laboratory workflows, enhances reproducibility and supports both standard and innovative applications in analytical chemistry.

Reference


No external references were provided in the original text.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Clarity Control Module SPARK ENDURANCE
SPARK ENDURANCE Clarity Control Module ENG Code/Rev.: M119/100A Date: 2025-05-12 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
endurance, endurancespark, sparkautosampler, autosamplersetup, setupdialog, dialogwash, washclarity, claritycommunication, communicationsampler, samplermethod, methodtab, tabinjection, injectionvolume, volumetimebase, timebasessv
Clarity Control Module SPARK INTEGRITY
SPARK INTEGRITY Clarity Control Module ENG Code/Rev.: M197/100A Date: 2025-05-12 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
spark, sparkintegrity, integrityneedle, needleautosampler, autosamplerdialog, dialogmove, movetray, traycommunication, communicationsyringe, syringeposition, positionstripper, stripperclarity, claritywash, washsetup, setuphomix
Clarity Control Module SPARK ALIAS
SPARK ALIAS Clarity Control Module ENG Code/Rev.: M102/100A Date: 2025-05-12 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
alias, aliasspark, sparkcommunication, communicationautosampler, autosamplersetup, setupclarity, claritydialog, dialogtab, tabtray, trayvial, vialwash, washset, setsequence, sequencesyringe, syringevolume
Clarity Control Module SPARK OPTIMAS
SPARK OPTIMAS Clarity Control Module ENG Code/Rev.: M234/90C Date: 2024-02-14 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
optimas, optimasspark, sparkautosampler, autosamplersetup, setupdialog, dialogtab, tabcommunication, communicationclarity, claritymethod, methodset, setsequence, sequenceevent, eventrun, runoutput, outputdefined
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike