LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Sugars in Cola Drink Using Accucore 150-Amide-HILIC

Applications | 2013 | Thermo Fisher ScientificInstrumentation
HPLC, Consumables, LC columns
Industries
Food & Agriculture
Manufacturer
Thermo Fisher Scientific

Summary

Importance of the Topic


Polar sugars like fructose and glucose are crucial to monitor in food and pharmaceutical products. Accurate quantification ensures quality control in beverages, syrups, and medicated formulations, addressing both regulatory requirements and consumer health concerns.

Objectives and Study Overview


This study demonstrates a robust chromatographic approach for the separation and detection of high concentrations of fructose, glucose, and cetylpyridinium in a cola drink matrix. The main goal is to achieve sharp peak shapes and minimize broadening caused by sugar isomerization.

Methodology and Instrumentation


  • Column: Thermo Scientific Accucore Surfactant Plus, 150-Amide-HILIC, 2.6 µm, 3.0 × 150 mm
  • Systems: Thermo Scientific Dionex ICS-3000 ion chromatography system and UltiMate 3000 LC system
  • Mobile Phases: A – Acetonitrile; B – 100 mM formic acid (85:15 v/v) with 10 mM sodium perchlorate
  • Gradient: 0–12 min gradient program, 1.0 mL/min flow rate; column temperature 50 °C; injection volume 5 µL of degassed sample
  • Detection: Refractive index detector for neutral sugars; suppressed conductivity detection with Thermo Scientific Dionex CSRS 300 suppressor (2 mm, external water 1.0 mL/min, 8 mA)

Main Results and Discussion


The method achieved baseline separation of fructose, glucose, and cetylpyridinium within six minutes. Operating the column at elevated temperature accelerated interconversion of sugar isomers, reducing peak broadening. Refractive index detection accommodated high sugar levels, while suppressed conductivity provided interference-free analysis of ionic species.

Benefits and Practical Applications


  • Fast, high-resolution analysis suited for routine quality control
  • Minimal sample preparation (simple degassing)
  • Dual detection modes enable simultaneous monitoring of neutral and charged analytes
  • Applicable to food, beverage, and pharmaceutical testing laboratories

Future Trends and Applications


Advances in HILIC stationary phases with optimized surface chemistries may further enhance isomer separation. Integration with mass spectrometry will improve selectivity in complex matrices. Trends toward automation and miniaturization will broaden use in on-site and point-of-care testing.

Conclusion


The 150-Amide-HILIC method on Accucore Surfactant Plus offers efficient, reproducible separation and detection of sugars and quaternary ammonium compounds in a cola drink matrix. Its high throughput, simple sample preparation, and dual detection capability make it an effective tool for analytical laboratories focused on carbohydrate and ionic analysis.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Sugars in Honey Using Accucore 150-Amide-HILIC
Sugars in Honey Using Accucore 150-Amide-HILIC
2013|Thermo Fisher Scientific|Applications
Mouthwash Using SugarsCetylpyridinium in Honey Using in Accucore 150-Amide-HILIC Acclaim Surfactant Plus with Conductivity Detection 20 300 RIU 1 mAU 2 2 UV 220 nm 0 1 3 2 µS 0 Conductivity 0 ™ Column: ThermoThermo Scientific™ Column:…
Key words
surfactant, surfactantconductivity, conductivitysubtraction, subtractionhoney, honeyaccucore, accucoreplus, plusacclaim, acclaimscientific, scientificacclaimsilica, acclaimsilicaascolumn, ascolumnfromused, fromusedgoodas, goodassaltssweetening, saltssweeteningsugarscetylpyridinium, sugarscetylpyridiniumthatcolumn
Sorbitol in Mouthwash Using Accucore 150-Amide-HILIC
Sorbitol in Mouthwash Using Accucore 150-Amide-HILIC
2009|Thermo Fisher Scientific|Applications
in Mouthwash Using Sorbitol inCetylpyridinium Mouthwash Using Accucore 150-Amide-HILIC Acclaim Surfactant Plus with Conductivity Detection ™ Column: ThermoThermo Scientific™ Column: Scientific Acclaim™Accucore™ Surfactant Plus 3.0 µm,150-Amide-HILIC, Dimensions: 3.0 × 150 mm 2.6 µm ™ ™ Dimensions: Thermo4.6…
Key words
mouthwash, mouthwashacclaim, acclaimconductivity, conductivityantibacterial, antibacterialsorbitol, sorbitolsubtraction, subtractionsurfactant, surfactantplus, plusaccucore, accucorecoverinthe, coverinthemildusually, mildusuallynmsorbitol, nmsorbitolsosurfactant, sosurfactanttoothconveniently, toothconvenientlyincetylpyridinium
RNA Nucleosides Using Accucore 150-Amide-HILIC
RNA Nucleosides Using Accucore 150-Amide-HILIC
2013|Thermo Fisher Scientific|Applications
Cetylpyridinium Mouthwash Using RNA Nucleosides Usingin Accucore 150-Amide-HILIC Acclaim Surfactant Plus with Conductivity Detection 70 300 mAU ™ ™ Column: Thermo Scientific™ Accucore™ Column: Thermo Scientific Acclaim Surfactant Plus 150-Amide-HILIC, Dimensions: 3.0 µm, 3.0 × 150 mm 2.6 µm…
Key words
surfactant, surfactantacclaim, acclaimconductivity, conductivitycetylpyridinium, cetylpyridiniumsubtraction, subtractionthermo, thermoplus, plusaccucore, accucorearenucleic, arenucleicbasesagents, basesagentsispeak, ispeakredundantinterference, redundantinterferenceribonucleosides, ribonucleosidesscientific, scientificrna
Sugar Phosphates Using GlycanPac AXH-1
Sugar Phosphates Using GlycanPac AXH-1
2013|Thermo Fisher Scientific|Applications
Cetylpyridinium in Mouthwash Using Sugar Phosphates Acclaim Surfactant with Conductivity Detection UsingPlus GlycanPac AXH-1 ™ ™ Column: Thermo Scientific™ GlycanPac™ Column: Thermo Scientific Acclaim Surfactant Plus AXH-1, µmmm Dimensions: 3.0 µm, 3.0 1.9 × 150 ™ ™ Dimensions: Thermo 2.1…
Key words
glycanpac, glycanpacsurfactant, surfactantacclaim, acclaimscientific, scientificconductivity, conductivityacetylpyridinium, acetylpyridiniumalkylphosphate, alkylphosphatebyconductivity, byconductivityfilternm, filternmglycanpacseparates, glycanpacseparatesmlsubtraction, mlsubtractionpeakanionic, peakanionicpharmaceuticalprevious, pharmaceuticalpreviousproductschromatographic, productschromatographicprovidesthem
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike