Nitrofuran Antibiotics in Animal Feed on a Thermo Scientific™ Acclaim ™ 120 C18 Column
Applications | 2009 | Thermo Fisher ScientificInstrumentation
Monitoring nitrofuran antibiotics in animal feed is critical due to their prohibited status in many regions and potential health risks. Accurate detection ensures regulatory compliance, protects public health, and maintains industry quality standards.
R.J. McCracken and D.G. Kennedy aimed to develop a robust isocratic HPLC–DAD method to separate and quantify four common nitrofuran residues (nitrofurazone, nitrofurantoin, furazolidone, furaltadone) in complex animal feed matrices.
Sample preparation involved:
The method achieved complete baseline separation of all four nitrofurans within 12 minutes, even in the presence of feed matrix interferences. Recovery experiments at 5 and 20 mg/kg demonstrated satisfactory accuracy (recoveries within acceptance criteria) and precision. DAD spectral confirmation added specificity, verifying peak identity and purity.
Advancements may include coupling with LC–MS/MS to achieve lower detection limits, automating sample preparation to increase throughput, and expanding to multi-residue antibiotic screening platforms for comprehensive feed safety analysis.
The Acclaim 120 C18-based HPLC–DAD method provides a fast, robust, and sensitive approach to detect banned nitrofuran antibiotics in animal feed, supporting regulatory compliance and safeguarding public health.
McCracken RJ, Kennedy DG. J Chromatogr A. 1997;771:349–354.
Consumables, LC columns, HPLC
IndustriesFood & Agriculture
ManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
Monitoring nitrofuran antibiotics in animal feed is critical due to their prohibited status in many regions and potential health risks. Accurate detection ensures regulatory compliance, protects public health, and maintains industry quality standards.
Study Objectives and Overview
R.J. McCracken and D.G. Kennedy aimed to develop a robust isocratic HPLC–DAD method to separate and quantify four common nitrofuran residues (nitrofurazone, nitrofurantoin, furazolidone, furaltadone) in complex animal feed matrices.
Methodology
Sample preparation involved:
- Weighing 3.0 g of feed into a centrifuge tube
- Adding 9 mL water, standing for 5 minutes
- Extracting with 21 mL methanol:acetonitrile (1:1) for 30 minutes
- Cleaning up on a neutral alumina cartridge (discard first 1.7 mL, collect next 3.5 mL)
Used Instrumentation
- Thermo Scientific Dionex Summit P680A DGP-6 pump
- Dionex Summit ASI100 autosampler
- Dionex Summit UVD340U diode array detector
- Thermo Scientific Acclaim 120 C18 column (5 µm, 4.6 × 150 mm)
Main Results and Discussion
The method achieved complete baseline separation of all four nitrofurans within 12 minutes, even in the presence of feed matrix interferences. Recovery experiments at 5 and 20 mg/kg demonstrated satisfactory accuracy (recoveries within acceptance criteria) and precision. DAD spectral confirmation added specificity, verifying peak identity and purity.
Benefits and Practical Applications
- Rapid, reliable screening for illegal nitrofuran residues in animal feed
- High specificity through spectral confirmation
- Suitable for routine quality control and regulatory testing laboratories
Future Trends and Potential Applications
Advancements may include coupling with LC–MS/MS to achieve lower detection limits, automating sample preparation to increase throughput, and expanding to multi-residue antibiotic screening platforms for comprehensive feed safety analysis.
Conclusion
The Acclaim 120 C18-based HPLC–DAD method provides a fast, robust, and sensitive approach to detect banned nitrofuran antibiotics in animal feed, supporting regulatory compliance and safeguarding public health.
References
McCracken RJ, Kennedy DG. J Chromatogr A. 1997;771:349–354.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Recovery of Nitrofuran Antibiotics from Pet Food on a Thermo Scientific™ Acclaim™ 120 C18 RSLC Column
2009|Thermo Fisher Scientific|Applications
Recovery of Nitrofuran Antibiotics from Pet Food on a Thermo Scientific™ Acclaim™ 120 C18 RSLC Column 10 LC System: 1 2 Thermo Scientific™ Dionex™ UltiMate™ 3000 RS Column: Thermo Scientific™ Acclaim™ 120 C18, 2.2 µm, 2.1 × 50 mm Mobile…
Key words
nitrofuran, nitrofuranantibiotics, antibioticsbanned, bannedrecovery, recoverypet, petcleanup, cleanuppass, passdionex, dionexcartridge, cartridgeparts, partsnow, nowmau, mauminutes, minutesfood, foodfrom
Determination of the Metabolites of Nitrofuran Antibiotics in Animal Tissues and Food Products by UPLC-MS/MS
2016|Waters|Applications
[ APPLICATION NOTE ] Determination of the Metabolites of Nitrofuran Antibiotics in Animal Tissues and Food Products by UPLC-MS/MS Simon Hird1 and Richard Ginn 2 1 Waters Corporation, Wilmslow, UK; 2 Fera Science Ltd, York, UK APPLICATION BENEFITS INTRODUCTION Specific,…
Key words
min, minnitrofuran, nitrofurantissues, tissuesuplc, uplcantibiotics, antibioticsmetabolites, metabolitesanimal, animalfood, foodxevo, xevonitrofurans, nitrofuransresidual, residualbound, boundmicro, microdetermination, determinationresponse
Food Safety Applications Notebook - Agricultural Chemical Contaminants
2012|Agilent Technologies|Guides
• Veterinary Drugs/Antibiotics • Pesticides Food Safety Applications Notebook Agricultural Chemical Contaminants Table of Contents Index of Analytes and Application Notes................................................................................................................................... 3 Introduction to Food Safety......................................................................................................................................................... 4 UltiMate 3000 UHPLC+ Systems............................................................................................................................................... 5 IC and RFIC Systems.................................................................................................................................................................. 6 MS Instruments........................................................................................................................................................................... 7…
Key words
ase, aseionpac, ionpacextraction, extractionammonium, ammoniumquaternary, quaternaryaccelerated, acceleratedcarbamate, carbamatealkanol, alkanolsolvent, solventanimal, animalsubstrate, substratehydroxide, hydroxidepsa, psalatex, latexmeat
Sulfonamide Antibiotic Residues in Milk on a Thermo Scientific™ Acclaim ™ 120 C18 Column
2010|Thermo Fisher Scientific|Applications
Sulfonamide Antibiotic Residues in Milk on a Thermo Scientific™ Acclaim™ 120 C18 Column 40 Column: 1 234 (C) m AU 5 Pump: 6 7 8 Mobile Phase: (B) * (A) 0 5 10 15 Minutes 20 25 Thermo Scientific™ Acclaim™…
Key words
milk, milksulfonamide, sulfonamideantibiotic, antibioticmoved, moveddionex, dionexnotes, notesresidues, residuesconfirmation, confirmationway, wayextract, extractmethanol, methanolspectral, spectralminutes, minutessmall, smallthermo