CLARITY 10.0 WHAT'S NEW

Presentations | 2024 | DataApexInstrumentation
Software
Industries
Other
Manufacturer
DataApex

Summary

Importance of the Topic


In modern analytical laboratories, software platforms that manage chromatography data play a critical role in ensuring data integrity, compliance with regulatory standards, and efficient workflow. The release of Clarity 10.0 enhances these capabilities by introducing new data acquisition modes, compliance features, and extended support for a wide range of control modules.

Objectives and Overview


The main goal of this update is to streamline simultaneous analysis, strengthen Good Laboratory Practice (GLP) compliance, and expand flexibility in controlling instrumentation. Key enhancements include:
  • Dual Chromatogram Mode for simultaneous front/back signal processing
  • Improved GLP user account management and audit trail features
  • Real-time isoplot and spectral displays in the acquisition window
  • Extended method adaptation messaging
  • Advancements in mass spectrometry (MS) extension
  • Natural Gas Analysis (NGA) calculations per EN ISO 6976:2016
  • External control module installer for third-party modules
  • Numerous new and updated control modules

Methodology and Instrumentation


Dual Chromatogram Mode relies on instruments equipped with twin sampling paths (GC dual-tower or LC dual-loop) and at least two detector channels, each designated as Front or Back. Method setup separates calculation and advanced parameters into two sub-tabs, and sequence tables duplicate core columns for front and back vials using a fixed offset logic.
Used Instrumentation:
  • Gas Chromatographs with dual-tower samplers
  • Liquid Chromatographs with dual-loop samplers
  • Detectors configured for front/back signal assignment
  • Mass spectrometer and photodiode array (PDA) detectors for real-time spectra and isoplot display

Key Results and Discussion


Implementation of Dual Chromatogram Mode allows parallel analysis of two sample streams without extended runtimes. GLP improvements introduce automated and manual account disabling, login attempt limits, and refined audit trail print-outs with header details. The data acquisition interface now offers live displays of MS spectra, PDA spectra, and isoplot visualizations. Method adaptation notices have been enriched with explicit reasons for modifications. MS extension supports library selection in single compound searches and enables MS method configuration directly from chromatograms. NGA routines have been updated to handle both wet- and dry-basis heating value calculations in line with EN ISO 6976:2016.

Benefits and Practical Applications


The new features enhance laboratory productivity by reducing cycle times through parallel analyses, reinforce data security and compliance through granular account controls, and improve decision-making with real-time spectral feedback. Flexible module installation empowers users to integrate emerging detectors or custom hardware outside regular software release cycles.
  • Increased throughput via dual chromatogram processing
  • Enhanced compliance and traceability in regulated environments
  • Improved method development with live spectral and isoplot feedback
  • Customizable control module deployment for evolving instrumentation needs

Future Trends and Opportunities


Looking ahead, integration with cloud-based services for remote monitoring and advanced data analytics can further optimize laboratory operations. Machine learning-driven peak detection and automated method development may be layered onto the existing platform. Expanded instrument support, including novel detectors and multi-dimensional separations, will broaden analytical capabilities.
  • Cloud connectivity for distributed data access and collaboration
  • AI-assisted data processing and method optimization
  • Support for emerging separation technologies and detectors
  • Enhanced interoperability with laboratory information management systems (LIMS)

Conclusion


Clarity 10.0 delivers a comprehensive suite of software enhancements aimed at boosting efficiency, ensuring compliance, and extending flexibility in instrument control. These updates position laboratories to handle more complex workflows and evolving regulatory demands while laying the groundwork for future innovation in chromatography data systems.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Clarity (Lite) 10.0 vs 9.0
Clarity (Lite) 10.0 vs 9.0
2024|DataApex|Manuals
10.0 VS 9.0 Clarity (Lite) ENG Code/Rev.: M252/100A Date: 12/3/2024 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic Sections of the manual connected only to the Clarity Full version are…
Key words
chromass, chromassyoung, youngupdated, updatedcontents, contentsversion, versionmodule, moduletable, tablecontrol, controlchrozengc, chrozengcbeen, beenclarity, clarityhas, haschrozenas, chrozenaschrozenpump, chrozenpumpadaptation
CLARITY 7.4 WHAT‘S NEW
CLARITY 7.4 WHAT‘S NEW
|DataApex|Presentations
P042/70A 4.10.2017 CLARITY 7.4 WHAT‘S NEW What is new in Clarity 7.4 ✓ GLP – Improved logging to Audit Trail ✓ Calibration on All Signals/Active Signal ✓ Agilent Instrument Control (ICF) – changes ✓ Various improvements – see Whatsnew ✓…
Key words
icf, icfglp, glpmodules, modulesnew, newchanges, changescontrol, controlvarious, variouscalibration, calibrationtrail, trailaudit, auditwindows, windowsoption, optionrecorded, recordedvista, vistasignals
CLARITY 8.0 WHAT‘S NEW
CLARITY 8.0 WHAT‘S NEW
|DataApex|Presentations
P048/80B 15.7.2018 CLARITY 8.0 WHAT‘S NEW What is new in Clarity 8.0 ✓ Graphically enhanced user interface ✓ Improvements to GLP compliance ✓ Increased number of ISTD‘s ✓ Improvements in MS extension ✓ Various changes and bug fixes ✓ New…
Key words
gui, guiglp, glpmodules, modulesistd, istdnew, newcontrol, controlsearch, searchtrail, trailgraph, graphistd‘s, istd‘smonitoracquisition, monitoracquisitionrainbowc, rainbowcsinglesequencedevice, singlesequencedeviceaudit, auditupdated
CLARITY 9.0 WHAT'S NEW
CLARITY 9.0 WHAT'S NEW
2023|DataApex|Presentations
CLARITY 9.0 WHAT‘S NEW WHAT IS NEW IN CLARITY 9.0? Improvements of the Integration Algorithm – new algorithm Wave based on previous Experimental Batch dialog redesign, improved handling of calibration during reprocessing Improvements in Audit Trail Clarity design adjusted to…
Key words
what‘s, what‘snew, newimprovements, improvementsalgorithm, algorithmupgrade, upgradeintegration, integrationwave, waveupdated, updatedmove, movepaid, paidfixed, fixedbarcode, barcodebugs, bugstrail, trailaudit
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike