Separation of Alkyl Quaternary Amines Using Acclaim Surfactant Plus with Conductivity Detection
Applications | 2012 | Thermo Fisher ScientificInstrumentation
Cationic surfactants often produce broad asymmetrical peaks on conventional silica based columns due to secondary interactions with residual silanol groups.
This challenge underscores the need for specialized stationary phases that can achieve sharp peaks, reliable retention, and high selectivity.
This study aims to demonstrate the performance of the Thermo Scientific Acclaim Surfactant Plus column for the separation of eight alkyl quaternary amines using suppressed conductivity detection.
The goal is to achieve baseline resolution and symmetrical peak shapes in a single run.
Separation employed a Thermo Scientific Dionex ICS 3000 IC system equipped with a CSRS 300 suppressor operated at 8 mA and external water flow at 1.0 mL/min.
Chromatography used an Acclaim Surfactant Plus column (3.0 × 150 mm, 3 µm) at 25 °C with a flow rate of 0.5 mL/min and 5 µL injection volume.
Mobile phases comprised acetonitrile (A), 100 mM formic acid (B), and water (C) with a gradient from 5% A/5% B/90% C to 40% A/5% B/55% C over 20 minutes.
Eight quaternary ammonium compounds from tetrabutylammonium to hexadecyltrimethylammonium were separated with excellent selectivity and peak symmetry.
Baseline resolution was achieved for all analytes within a 20 min run, illustrating the column’s ability to handle varying hydrophobicities and alkyl chain lengths.
The specialized surface chemistry of the column minimized silanol interactions, resulting in narrow peaks and improved sensitivity.
The method offers a robust, reliable approach for routine QC of cationic surfactants in formulations, environmental samples, and industrial processes.
Its compatibility with multiple detection modes including MS and aerosol detectors expands its applicability in research and regulatory testing.
Expected developments include coupling this approach with high resolution MS for structural elucidation, high throughput workflows, and expanded libraries of surfactant standards.
Advances in stationary phase design may further improve selectivity for mixed surfactant systems in complex matrices.
The Acclaim Surfactant Plus column, combined with suppressed conductivity detection, provides an efficient and sensitive solution for the separation of alkyl quaternary amines.
Its superior peak shapes and resolution streamline analytical workflows in various lab settings.
LC columns, Consumables, HPLC
IndustriesEnergy & Chemicals
ManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
Cationic surfactants often produce broad asymmetrical peaks on conventional silica based columns due to secondary interactions with residual silanol groups.
This challenge underscores the need for specialized stationary phases that can achieve sharp peaks, reliable retention, and high selectivity.
Objectives and Study Overview
This study aims to demonstrate the performance of the Thermo Scientific Acclaim Surfactant Plus column for the separation of eight alkyl quaternary amines using suppressed conductivity detection.
The goal is to achieve baseline resolution and symmetrical peak shapes in a single run.
Methodology and Instrumentation
Separation employed a Thermo Scientific Dionex ICS 3000 IC system equipped with a CSRS 300 suppressor operated at 8 mA and external water flow at 1.0 mL/min.
Chromatography used an Acclaim Surfactant Plus column (3.0 × 150 mm, 3 µm) at 25 °C with a flow rate of 0.5 mL/min and 5 µL injection volume.
Mobile phases comprised acetonitrile (A), 100 mM formic acid (B), and water (C) with a gradient from 5% A/5% B/90% C to 40% A/5% B/55% C over 20 minutes.
- IC system: Thermo Scientific Dionex ICS 3000
- Column: Acclaim Surfactant Plus, 3.0 × 150 mm, 3 µm
- Detector: Conductivity with CSRS 300 suppressor
- Mobile phases: Acetonitrile; 100 mM formic acid; water
- Gradient: 5–40% A over 12 min, hold to 20 min
- Flow rate: 0.5 mL/min; Injection: 5 µL; Temperature: 25 °C
Main Results and Discussion
Eight quaternary ammonium compounds from tetrabutylammonium to hexadecyltrimethylammonium were separated with excellent selectivity and peak symmetry.
Baseline resolution was achieved for all analytes within a 20 min run, illustrating the column’s ability to handle varying hydrophobicities and alkyl chain lengths.
The specialized surface chemistry of the column minimized silanol interactions, resulting in narrow peaks and improved sensitivity.
Contributions and Practical Applications
The method offers a robust, reliable approach for routine QC of cationic surfactants in formulations, environmental samples, and industrial processes.
Its compatibility with multiple detection modes including MS and aerosol detectors expands its applicability in research and regulatory testing.
Future Trends and Potential Applications
Expected developments include coupling this approach with high resolution MS for structural elucidation, high throughput workflows, and expanded libraries of surfactant standards.
Advances in stationary phase design may further improve selectivity for mixed surfactant systems in complex matrices.
Conclusion
The Acclaim Surfactant Plus column, combined with suppressed conductivity detection, provides an efficient and sensitive solution for the separation of alkyl quaternary amines.
Its superior peak shapes and resolution streamline analytical workflows in various lab settings.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Cationic Surfactants Using Acclaim Surfactant Plus with Suppressed Conductivity Detection
2012|Thermo Fisher Scientific|Applications
Cationic Surfactants Using Acclaim Surfactant Plus with Suppressed Conductivity Detection Columns: 5 2 1 4 5 6 µS 3 Thermo Scientific™ Acclaim™ Surfactant Plus, 3.0 µm Dimensions: 3.0 × 150 mm LC System: Thermo Scientific™ Dionex™ ICS-3000™ IC system Mobile…
Key words
cationic, cationicsurfactants, surfactantsconductivity, conductivitysurfactant, surfactantacclaim, acclaimsuppressed, suppressedplus, plusundesired, undesiredsilanol, silanolsubtraction, subtractionionic, ionicinteractions, interactionsdetection, detectionsilica, silicadifficult
Quaternary Surfactants on a Thermo Scientific™ Acclaim™ Surfactant Column with Suppressed Conductivity Detection
2009|Thermo Fisher Scientific|Applications
Quaternary Surfactants on a Thermo Scientific™ Acclaim™ Surfactant Column with Suppressed Conductivity Detection 5 Column: Thermo Scientific™ Acclaim™ Surfactant 5 µm, 4.6 × 150 mm Pump: Thermo Scientific™ Dionex™ ICS-3000 DP Mobile Phases: (A) Water (B) 100 mM formic acid…
Key words
thermo, thermosurfactants, surfactantsacclaim, acclaimmicrobiocides, microbiocidesscientific, scientificsuppressed, suppressedquaternary, quaternarydionex, dionexconductivity, conductivitycsrs, csrspreservatives, preservativessurfactant, surfactantminutes, minutesdetection, detectioncolumn
Cationic Impurities in Colesevelam Analyzed by MPIC Using IonPac NS2
2013|Thermo Fisher Scientific|Applications
Cetylpyridinium in Colesevelam Mouthwash Using Cationic Impurities in Analyzed Acclaim Surfactant Plus withIonPac Conductivity by MPIC Using NS2 Detection 300 3.0 mAU S total ID-1 2 UV 220 nm 0 ID-2 ID-5 ID-4 1 3 ID-7 ID-3 2 µS ID-6…
Key words
colesevelam, colesevelammpic, mpicsurfactant, surfactantacclaim, acclaimconductivity, conductivitycetylpyridinium, cetylpyridiniumscientific, scientificdionex, dionexplus, plusacidssuch, acidssuchandgood, andgoodandimpurities, andimpuritiesiscough, iscoughsequesteringproducts, sequesteringproductstoagents
Quaternary Surfactants in a Cosmetic Formulation Using Acclaim Surfactant Plus
2013|Thermo Fisher Scientific|Applications
Cetylpyridinium Quaternary SurfactantsininMouthwash a CosmeticUsing Formulation Acclaim Surfactant Plus with Conductivity Using Acclaim Surfactant Plus Detection 300 120 pA mAU 6 1 2 3 4 2 5 0 6 1 2 1 3 5 µS 1 0 2 2 ™…
Key words
surfactant, surfactantacclaim, acclaimscientific, scientificconductivity, conductivityplus, plusquaternary, quaternarysubtraction, subtractionthermo, thermosurfactants, surfactantsandactive, andactiveareinterference, areinterferencecosmeticusing, cosmeticusingcurrentcorona, currentcoronaplusmm, plusmmsilicacetylpyridinium