Summary

Significance of the Topic


Supercritical fluid chromatography (SFC) is increasingly valued for its high throughput, efficient separation of structurally related compounds, and low mobile-phase viscosity. However, optimizing SFC methods conventionally requires extensive manual screening of stationary phases, modifiers, gradient profiles, temperatures, and pressures. Automating this process can dramatically reduce development time, minimize human error, and improve reproducibility in pharmaceutical, environmental, and industrial analyses.

Study Objectives and Overview


This study presents a comprehensive workflow for SFC method development using Shimadzu’s LabSolutions MD software and the Nexera UC system. A mixture of six pharmaceutical compounds was used to demonstrate automated screening of six different column chemistries and seven modifier conditions, followed by systematic optimization of additive concentration, gradient time, column oven temperature, and backpressure to identify robust separation conditions.

Methodology


The workflow involved five key steps:
  • Selecting six SFC columns with distinct stationary phases (diol, silica, polyether, brominated, C18, vinylpyrrolidone) to span normal-phase, reversed-phase, π-π and hydrophobic interactions.
  • Screening three modifier mixtures (100% methanol, 50:50 methanol/acetonitrile, 100% acetonitrile) using LabSolutions MD’s schedule generator.
  • Evaluating six model pharmaceuticals (antipyrine, probenecid, naproxen, hydrocortisone, clozapine, indomethacin) under a fixed gradient (5→70% B over 7 min) at 30 °C and 10 MPa.
  • Quantitatively ranking separations using an Evaluation Value metric (number of peaks × sum of resolutions).
  • Refining modifier composition, gradient time, temperature, and backpressure via design-space overlays to meet resolution criteria for critical peak pairs.

Applied Instrumentation


The automated workflow employed:
  • Nexera UC supercritical fluid chromatography system with dual pumps for CO₂ and organic solvents.
  • Column switching valves accommodating six columns in sequence.
  • Mobile-phase switching valves for seven solvent lines, enabling on-the-fly blending of methanol, acetonitrile, water, ammonium formate, acetate, and formic acid solutions.
  • Autosampler, column oven, backpressure regulator, and a photodiode array detector with high-pressure flow cell.
  • LabSolutions MD software for schedule generation, data acquisition, evaluation value calculation, and design-space visualization.

Main Results and Discussion


Initial screening identified the UC-PBr column with 100% methanol modifier as delivering the highest Evaluation Value, although clozapine exhibited tailing. Modifier optimization revealed that adding 20 mM ammonium formate and 5% water sharpened peaks and improved resolution between clozapine and indomethacin. Further variation of gradient time (5–7 min), oven temperature (20–40 °C), and backpressure (10–20 MPa) demonstrated predictable influences on retention and resolution. Overlaying design spaces for resolution ≥3.5 for critical pairs guided selection of optimal conditions (6 min gradient, 30 °C, 10 MPa). Increasing flow rate to 1.5 mL/min under these conditions maintained resolution while reducing analysis time, leveraging the low viscosity and high diffusivity of supercritical CO₂.

Benefits and Practical Applications


  • Automated column and modifier switching reduces manual preparation and potential errors.
  • Quantitative Evaluation Value enables objective ranking of hundreds of chromatograms.
  • Design-space overlays allow multi-parameter optimization without expert intuition.
  • High flow-rate capability of SFC permits shorter run times without sacrificing efficiency.
  • Suitable for rapid pharmaceutical impurity profiling, quality control, and high-throughput screening.

Future Trends and Applications


Integration of SFC with liquid chromatography (LC)/SFC switching systems promises broader selectivity coverage and faster method development. Advances in AI-driven parameter selection, greener solvent blends, and high-pressure automation will further streamline workflows. Expansion of design-space tools to incorporate robustness criteria and real-time feedback may enable self-optimizing analytical platforms.

Conclusion


The combination of LabSolutions MD software with the Nexera UC SFC system enables fully automated, rapid, and reproducible method development. By leveraging automated column and modifier switching, quantitative evaluation metrics, and design-space optimization, laboratories can significantly reduce development time and reliance on expert chromatographers while achieving high-quality separations.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Diversification of Separation Selectivity Using Supercritical Fluid Chromatography
Supercritical Fluid Chromatography System / Ultra High Performance Liquid Chromatograph Diversification of Separation Selectivity Using Supercritical Fluid Chromatography Application News -Efficient Search for Optimal Separation Conditions by Combining LC and SFCShinichi Fujisaki User Benefits  Because LC and SFC have…
Key words
sfc, sfcsupercritical, supercriticalprobenecid, probenecidantipyrine, antipyrineindomethacin, indomethacinclozapine, clozapineswitching, switchinghydrocortisone, hydrocortisonenaproxen, naproxenscreening, screeninginquiry, inquirymobile, mobilemodifier, modifierseparation, separationnexera
Efficient Optimization of Separation Conditions for Synthetic Peptide Using Super Critical Fluid Chromatography
Supercritical Fluid Chromatography System Nexera UC Software for Efficient Method Development LabSolutions MD Application News Efficient Optimization of Separation Conditions for Synthetic Peptide Using Super Critical Fluid Chromatography Yusuke Masuda User Benefits  Supercritical fluid chromatography (SFC) can be applied…
Key words
angiotensin, angiotensinmodifier, modifiershim, shimpack, packmin, minseparation, separationscreening, screeningmau, mauwater, waterlabsolutions, labsolutionsrank, rankbasic, basicnexera, nexeranews, newsfluid
Study of Effective Parameters for Separation of Isomers of Fluorescent Substance by Supercritical Fluid Chromatography
C190-E229 Technical Report Study of Effective Parameters for Separation of Isomers of Fluorescent Substance by Supercritical Fluid Chromatography Keiko Matsumoto1, Yasuhiro Funada1 A b s tra c t: In order to detect the sites of trace amounts of cancers within…
Key words
demethylated, demethylatedmau, maucarboxytetramethylrhodamine, carboxytetramethylrhodaminegroup, groupbpr, bprmin, minshim, shimpack, packphase, phasemobile, mobilepyrenylethyl, pyrenylethyldiol, diolpentabromobenzyl, pentabromobenzylgradient, gradientrate
Simultaneous Analysis of Carboxylic Anhydrides and Hydrolysates Using Supercritical Fluid Chromatography
Supercritical Fluid Chromatograph Nexera™ UC Simultaneous Analysis of Carboxylic Anhydrides and Hydrolysates Using Supercritical Fluid Chromatography Application News Yusuke Masuda User Benefits  Supercritical Fluid Chromatography (SFC) allows analysis of carboxylic anhydrides without hydrolysis.  Efficient column scouting is possible…
Key words
bpda, bpdaodpa, odpaanhydrides, anhydrideshydrolyzed, hydrolyzedcarboxylic, carboxylichydrolysates, hydrolysatesshim, shimpack, packopda, opdasimultaneous, simultaneouspolybt, polybtpolyvp, polyvppbr, pbrsil, silmethod
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike