Empowering High-Throughput Proteomics Workflows with the Agilent ProteoAnalyzer System
Applications | 2025 | Agilent TechnologiesInstrumentation
The accuracy and throughput of protein sample quality control (QC) are foundational for reliable proteomics analyses. Traditional SDS-PAGE methods pose challenges including lengthy protocols, manual labor, narrow dynamic range, and difficulties in automation. These limitations hinder high-throughput laboratories from scaling up workflows and achieving consistent data management.
This application note evaluates the implementation of the Agilent ProteoAnalyzer system at a high-throughput proteomics facility (Majorbio). The study aims to compare the ProteoAnalyzer with conventional SDS-PAGE QC in terms of sensitivity, throughput, reproducibility, automation potential, and integration into downstream proteomics workflows.
Sample Preparation and Extraction
SDS-PAGE QC Workflow
ProteoAnalyzer QC Workflow
Instrumentation
Throughput and Labor Reduction
Sensitivity and Quantification Range
Reproducibility and Data Quality
Compatibility Across Sample Types
Integration into Proteomics Workflow
The ProteoAnalyzer system delivers high-throughput automated QC with reduced labor and bench space requirements. Its broad dynamic range and digital data outputs facilitate seamless integration into LIMS and downstream MS workflows. Laboratories can achieve consistent, scalable QC across diverse sample types while freeing personnel from repetitive manual tasks.
Advances in capillary electrophoresis automation and software integration are expected to further accelerate large-cohort proteomics. Coupling the ProteoAnalyzer with real-time data analytics and cloud-based management will enhance remote monitoring and decision-making. Adaptation of novel labeling chemistries may expand dynamic range and multiplexing capabilities.
The Agilent ProteoAnalyzer substantially outperforms traditional SDS-PAGE in sensitivity, throughput, and automation. It provides a robust, reproducible platform for protein QC that integrates seamlessly into high-throughput proteomics workflows, driving efficiency and data quality improvements.
Sample Preparation
IndustriesProteomics
ManufacturerAgilent Technologies
Summary
Significance of the Topic
The accuracy and throughput of protein sample quality control (QC) are foundational for reliable proteomics analyses. Traditional SDS-PAGE methods pose challenges including lengthy protocols, manual labor, narrow dynamic range, and difficulties in automation. These limitations hinder high-throughput laboratories from scaling up workflows and achieving consistent data management.
Objectives and Overview of the Study
This application note evaluates the implementation of the Agilent ProteoAnalyzer system at a high-throughput proteomics facility (Majorbio). The study aims to compare the ProteoAnalyzer with conventional SDS-PAGE QC in terms of sensitivity, throughput, reproducibility, automation potential, and integration into downstream proteomics workflows.
Methodology and Instrumentation
Sample Preparation and Extraction
- Animal tissues were powdered under cryogenic conditions and lysed in protease-inhibitor buffer.
- Ultrasonication and centrifugation yielded clarified protein extracts.
SDS-PAGE QC Workflow
- BCA assay for protein quantification and loading volume adjustment.
- Precast gels run at 180 V for 40–50 minutes followed by Coomassie staining and destaining (4 hours to overnight).
- Manual gel imaging and data annotation.
ProteoAnalyzer QC Workflow
- No pre-quantification step; direct loading of 1 μL protein per sample.
- Labeling with Protein Broad Range P240 kit under reducing conditions.
- Automated capillary electrophoresis and digital gel image generation.
- Automatic electropherogram overlay and batch report generation via ProSize software.
Instrumentation
- Agilent ProteoAnalyzer capillary electrophoresis system with Protein Broad Range P240 kit.
- Conventional SDS-PAGE setup (electrophoresis cells, staining/destaining apparatus, gel imager).
- Cryogenic grinder and ultrasonicator for sample disruption.
- High-resolution mass spectrometer for downstream proteomic analysis.
Main Results and Discussion
Throughput and Labor Reduction
- ProteoAnalyzer: single operator, bench footprint of one instrument, 12 samples per 30 minutes, minimal manual steps.
- SDS-PAGE: two operators, >5 hours hands-on time, multiple electrophoresis cells and fume-hood operations.
Sensitivity and Quantification Range
- ProteoAnalyzer detection limit as low as 1 ng/μL with a linear range spanning three orders of magnitude.
- SDS-PAGE shows limited sensitivity and a two-order magnitude range, requiring precise sample loading.
Reproducibility and Data Quality
- Overlay of digital electropherograms from ProteoAnalyzer demonstrated highly consistent band patterns across replicates.
- Internal markers (6 kDa and 240 kDa) provided reliable alignment and sizing accuracy.
Compatibility Across Sample Types
- Successful QC performance for diverse sources including animal tissues, plant tissues, fungi, bacteria, and algae.
- Stable digital gel output for large cohorts (e.g., 92 liver and 90 adipose samples) enabling rapid cohort assessment.
Integration into Proteomics Workflow
- ProteoAnalyzer quantification of total protein streamlined enzymatic digestion and peptide preparation.
- Fixed peptide input (300 ng) led to robust protein identifications (7,953–10,628 unique proteins across five sample types).
Benefits and Practical Applications
The ProteoAnalyzer system delivers high-throughput automated QC with reduced labor and bench space requirements. Its broad dynamic range and digital data outputs facilitate seamless integration into LIMS and downstream MS workflows. Laboratories can achieve consistent, scalable QC across diverse sample types while freeing personnel from repetitive manual tasks.
Future Trends and Opportunities
Advances in capillary electrophoresis automation and software integration are expected to further accelerate large-cohort proteomics. Coupling the ProteoAnalyzer with real-time data analytics and cloud-based management will enhance remote monitoring and decision-making. Adaptation of novel labeling chemistries may expand dynamic range and multiplexing capabilities.
Conclusion
The Agilent ProteoAnalyzer substantially outperforms traditional SDS-PAGE in sensitivity, throughput, and automation. It provides a robust, reproducible platform for protein QC that integrates seamlessly into high-throughput proteomics workflows, driving efficiency and data quality improvements.
References
- Agilent Protein Broad Range P240 Kit, Agilent Technologies Quick Guide, D0031125, 2023.
- Protein Sizing and Quantification with the Agilent ProteoAnalyzer System, Agilent Technologies Technical Overview, 5994-6718EN, 2023.
- Quality Analysis Using the Agilent ProteoAnalyzer System and SDS-PAGE, Agilent Technologies Technical Overview, 5994-6934EN, 2023.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Best Practices for Protein Analysis with the Agilent ProteoAnalyzer System
2024|Agilent Technologies|Applications
Technical Overview Best Practices for Protein Analysis with the Agilent ProteoAnalyzer System Introduction Reliable quality control (QC) of protein samples is essential to many workflows, including protein characterization and product release. Among the many different attributes of proteins, the size,…
Key words
ladder, ladderproteoanalyzer, proteoanalyzerrfu, rfukda, kdasize, sizesizing, sizingpbs, pbsbuffer, bufferbsa, bsanistmab, nistmabbuffers, bufferssample, sampleaverage, averageprosize, prosizeerror
Analysis of NIST Antibody on the Agilent ProteoAnalyzer System
2024|Agilent Technologies|Technical notes
Technical Overview Analysis of NIST Antibody on the Agilent ProteoAnalyzer System Introduction The National Institute of Standards and Technology (NIST), a branch of the US Department of Commerce, develops reference materials to foster the innovation and standardization of technology in…
Key words
proteoanalyzer, proteoanalyzernistmab, nistmabnonreduced, nonreducedthioether, thioetherpublished, publishednist, nistnghc, nghcrfu, rfudatasheet, datasheetassessment, assessmentmonomeric, monomericpurity, puritysds, sdscompared, comparedheterogeneity
Build Consistency into Your Lab’s Workflow
2024|Agilent Technologies|Brochures and specifications
Build Consistency into Your Lab’s Workflow With the Agilent Automated Electrophoresis portfolio Explore more Build Consistency with Reliable Sample Quality Assessment You can build consistency into your molecular biology lab’s workflow. Whether you perform low- or ultra-high-throughput testing, our automated…
Key words
proteoanalyzer, proteoanalyzerrna, rnatapestation, tapestationfemto, femtozag, zagdna, dnakits, kitsscreentape, screentapesystem, systemelectrophoresis, electrophoresissystems, systemsonsite, onsitepulse, pulseanalyzer, analyzeroligo
Fluorescence vs. UV Detection: Comparing Two CE-SDS Systems Using NISTmAb
2025|Agilent Technologies|Applications
Application Note Genomics Fluorescence vs. UV Detection: Comparing Two CE-SDS Systems Using NISTmAb Authors Abstract Timothy Butler and Sheng-Yuan Huang Agilent Technologies, Inc. Fluorescence and UV detection are commonly used in protein capillary electrophoresis. This study compares these detection methods…
Key words