A Total Solution for the Analysis of Melamine and Cyanuric Acid in Pet Food by GC/MS and Aqueous Normal-Phase LC/MS/MS
Applications | 2007 | Agilent TechnologiesInstrumentation
Analysis of melamine and cyanuric acid in pet food is critical following contamination events that caused animal fatalities. Reliable detection ensures consumer safety and regulatory compliance.
This work compares two analytical workflows: a GC/MS screening method incorporating trimethylsilyl derivatization and an aqueous normal-phase LC/MS/MS approach. The aim is to streamline sample preparation, enhance sensitivity, and provide confirmation and quantitation.
GC/MS Method
Optimized SIM ion selection in GC/MS improved signal-to-noise ratios and reduced matrix interference. LC/MS/MS achieved baseline separation in under 5 min, with calibration curves showing R² > 0.999 across broad concentration ranges. Spiked pet food and raw ingredient matrices demonstrated accurate recovery after minimal sample preparation and appropriate dilution.
The GC/MS protocol offers a robust screening and confirmation tool, while the HILIC LC/MS/MS workflow eliminates derivatization, simplifies preparation, and extends quantitation to trace levels. Both methods support quality control and regulatory testing in food and feed analysis.
Emerging directions include integrating hydrophilic interaction chromatography with high-resolution mass spectrometry for multiplexed contaminant analysis, automating sample processing, applying the approach to biological fluids, and developing on-site or real-time monitoring platforms.
Combining GC/MS and LC/MS/MS methodologies delivers complementary, sensitive, and efficient strategies for the surveillance of melamine and cyanuric acid in pet food, reinforcing food safety and compliance efforts.
1. U.S. FDA, GC-MS Screen for Melamine, Ammeline, Ammelide and Cyanuric Acid, Version 2, May 7, 2007.
2. K. I. Petrus Hemström, “Hydrophilic interaction chromatography,” Journal of Separation Science, 29(12), 1784–1821, 2006.
GC/MSD, GC/SQ, LC/MS, LC/MS/MS, LC/QQQ
IndustriesFood & Agriculture
ManufacturerAgilent Technologies
Summary
Significance of the Topic
Analysis of melamine and cyanuric acid in pet food is critical following contamination events that caused animal fatalities. Reliable detection ensures consumer safety and regulatory compliance.
Objectives and Study Overview
This work compares two analytical workflows: a GC/MS screening method incorporating trimethylsilyl derivatization and an aqueous normal-phase LC/MS/MS approach. The aim is to streamline sample preparation, enhance sensitivity, and provide confirmation and quantitation.
Methodology and Instrumentation
GC/MS Method
- Instrument: Agilent 7890A gas chromatograph with 5975C mass selective detector
- Column: DB-5MS (30 m×0.25 mm×0.25 µm)
- Derivatization: BSTFA for TMS formation at 70 °C for 45 min
- Acquisition: EI in SIM/SCAN mode, detection limit 10 µg/g
- Instrument: Agilent 1200SL RRLC coupled to 6410 Triple Quad
- Column: ZORBAX Rx-Sil HILIC (2.1 × 150 mm, 5 µm)
- Mobile phase: isocratic 95 % acetonitrile / 5 mM ammonium acetate in water
- Ionization: ESI with polarity switching, MRM for cyanuric acid (negative) and melamine (positive)
- Detection limits: 50 pg/mL for melamine, 1 ng/mL for cyanuric acid
Main Results and Discussion
Optimized SIM ion selection in GC/MS improved signal-to-noise ratios and reduced matrix interference. LC/MS/MS achieved baseline separation in under 5 min, with calibration curves showing R² > 0.999 across broad concentration ranges. Spiked pet food and raw ingredient matrices demonstrated accurate recovery after minimal sample preparation and appropriate dilution.
Benefits and Practical Applications
The GC/MS protocol offers a robust screening and confirmation tool, while the HILIC LC/MS/MS workflow eliminates derivatization, simplifies preparation, and extends quantitation to trace levels. Both methods support quality control and regulatory testing in food and feed analysis.
Future Trends and Opportunities
Emerging directions include integrating hydrophilic interaction chromatography with high-resolution mass spectrometry for multiplexed contaminant analysis, automating sample processing, applying the approach to biological fluids, and developing on-site or real-time monitoring platforms.
Conclusion
Combining GC/MS and LC/MS/MS methodologies delivers complementary, sensitive, and efficient strategies for the surveillance of melamine and cyanuric acid in pet food, reinforcing food safety and compliance efforts.
Reference
1. U.S. FDA, GC-MS Screen for Melamine, Ammeline, Ammelide and Cyanuric Acid, Version 2, May 7, 2007.
2. K. I. Petrus Hemström, “Hydrophilic interaction chromatography,” Journal of Separation Science, 29(12), 1784–1821, 2006.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
The Use of Hydrophilic Interaction Chromatography with Mass Spectrometry Detection for the Separation of Basic Pharmaceuticals and Food Toxins
|Agilent Technologies|Presentations
The Use of Hydrophilic Interaction Chromatography with Mass Spectrometry Detection for the Separation of Basic Pharmaceuticals and Food Toxins R.E. Majors*, Agilent Technologies,Wilmington, DE, USA; T. Yoshida and H. Kumagai, Agilent Technologies, Hachioji-Shi, Tokyo, Japan Page 1 Outline of Talk…
Key words
cyanuric, cyanuricranitidine, ranitidineparoxetine, paroxetinehilic, hilicmelamine, melaminerpc, rpcacid, acidphase, phaserplc, rplcabundance, abundanceretention, retentionmobile, mobilecolumns, columnsseparation, separationpair
Shimadzu LC World Talk 2011 Issue 1
2011|Shimadzu|Others
C190-E149 2011 Issue 1 LC World Talk SHIMADZU'S NEWSLETTER FOR THE HPLC GLOBAL COMMUNITY Shimadzu Introduces the LCMS-8030, the World’s Fastest Triple Quadrupole Mass Spectrometer n n LCMS-8030 Ultra Fast Tandem Quadrupole Mass Spectrometer, The Next Generation of Mass Spectrometer…
Key words
melamine, melamineimpurities, impuritiesmicrodialysis, microdialysispineal, pinealultra, ultramelatonin, melatoninfast, fastmobile, mobilecyanuric, cyanuricufsweeper, ufsweeperdimension, dimensioncolumn, columnmrm, mrmanalysis, analysisjetlag
Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS
2008|Thermo Fisher Scientific|Applications
Application Note: 424 Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS PeterVarelis, National Center for Food Safety and Technology, Illinois Institute of Technology. Jonathan Beck, Kefei Wang, and Dipankar Ghosh; Thermo Fisher Scientific, San Jose, CA Introduction…
Key words
melamine, melaminecyanuric, cyanuriccatfish, catfishacid, acidabundance, abundancespectrum, spectrumwere, werefood, foodratio, ratiorelative, relativeafrica, africanotices, noticeslibrary, libraryworldwide, worldwidefodder
Simultaneous Extraction of Melamine and Cyanuric Acid from Food Products Using Strata® Melamine SPE and Ultra-fast LC/MS/MS Analysis Using Kinetex™ HILIC, Rapid LC/MS/MS Analysis on Luna® HILIC, or Rapid GC/MS Analysis on Zebron™ ZB-XLB HT
2009|Agilent Technologies|Applications
TN-0021 APPLICATIONS Simultaneous Extraction of Melamine and Cyanuric Acid from Food Products Using Strata® Melamine SPE and Ultra-fast LC/MS/MS Analysis Using Kinetex™ HILIC, Rapid LC/MS/MS Analysis on Luna® HILIC, or Rapid GC/MS Analysis on Zebron™ ZB-XLB HT Shahana Wahab Huq,…
Key words
melamine, melaminecyanuric, cyanuricacid, acidzebron, zebronbaby, babyxlb, xlbinferno, infernoluna, lunakinetex, kinetexhilic, hilicstrata, strataformula, formulaextraction, extractioncomplete, completeextracts