Nitrogen Generator Infinity 50 Series

Brochures and specifications |  | Peak ScientificInstrumentation
Laboratory gases and gas generators
Industries
Manufacturer
Peak Scientific

Summary

Significance of the Topic


The supply of high-purity nitrogen is essential for numerous analytical techniques, including mass spectrometry, evaporative light scattering, and NMR. On-site generators provide continuous, reliable gas without logistical challenges or safety hazards related to cylinder storage.

Objectives and Overview


This summary presents the Infinity 50 Series nitrogen generators by Peak Scientific, highlighting their design goals, performance parameters, and suitability as a single-source solution for multiple laboratory applications.

Methodology and Instrumentation


The Infinity 50 Series employs on-site gas generation technology to separate nitrogen from compressed air. Key instrument components and requirements include:
  • Infinity 50 models 5010–5080, delivering 60–480 L/min nitrogen flow;
  • Clean, dry inlet air at 125–145 psi to drive separation modules;
  • Filtration stages removing particles (<0.01 µm), suspended liquids, and phthalates;
  • Integrated control for pressure dewpoint monitoring down to –40 °C;
  • Electrical supply compatibility: 110–230 V, 50/60 Hz.

Key Results and Discussion


Performance data demonstrate:
  • Nitrogen output scaled across eight models: 60, 120, 180, 240, 300, 360, 420, and 480 L/min;
  • Corresponding air demands of 180–1440 L/min;
  • Operating temperature window of 5–30 °C for reliable performance;
  • Compact footprint (50 × 80 × 115 cm) and weights ranging 70–105 kg;
  • Virtually silent operation and minimal maintenance from a design with few moving parts.

Benefits and Practical Applications


Adoption of Infinity 50 Series generators offers:
  • A single generator supporting multiple instruments and laboratories;
  • Cost savings compared to cylinder supply and reduced carbon footprint;
  • Elimination of gas cylinder handling and safety risks;
  • Scalable, mobile units on caster wheels for flexible lab deployment.

Future Trends and Potential Applications


Emerging developments in gas generator technology include digital monitoring and remote diagnostics, modular scaling to match evolving lab needs, and integration with laboratory information management systems. These enhancements will further improve uptime, predictive maintenance, and resource optimization.

Conclusion


The Infinity 50 Series by Peak Scientific combines high-capacity nitrogen production with user-friendly features, making it an effective solution for laboratories seeking reliable, cost-efficient, and eco-friendly gas supply. Its modular design and broad performance range meet the demands of diverse analytical techniques without the drawbacks of cylinder logistics.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Nitrogen Generator - Infinity 50 Series
Nitrogen Generator - Infinity 50 Series
2014|Peak Scientific|Brochures and specifications
Nitrogen Generator Infinity 50 Series Peak Infinity, beyond expectations. Perpetual flow Nitrogen generators The Infinity 50 series delivers performance and value beyond expectations, offering a pure and reliable source of gas. These perpetual flow Nitrogen generators are suitable for a…
Key words
generators, generatorsgenerator, generatorscientific, scientificnitrogen, nitrogenmaintenance, maintenanceplan, planpeak, peakair, airrequirements, requirementsnone, nonedewpoint, dewpointperpetual, perpetualmax, maxcaster, castercater
Nitrogen Generator - Infinity 90 Series
Nitrogen Generator - Infinity 90 Series
2014|Peak Scientific|Brochures and specifications
Nitrogen Generator Infinity 90 Series Peak Infinity, beyond expectations. Perpetual flow Nitrogen generators The Infinity 90 series delivers performance and value beyond expectations, offering a pure and reliable source of gas. These perpetual flow Nitrogen generators are suitable to supply…
Key words
generators, generatorsnone, nonegenerator, generatorscientific, scientificnitrogen, nitrogenmaintenance, maintenanceplan, planpeak, peakair, airrequirements, requirementsdewpoint, dewpointperpetual, perpetualmultiple, multiplemax, maxcaster
Infinity XE 5010-5040 Single nitrogen source for LC-MS
Infinity XE 5010-5040 Single nitrogen source for LC-MS
2020|Peak Scientific|Brochures and specifications
Infinity XE 5010-5040 Single nitrogen source for LC-MS Part Number : See Reverse Service Kit : See Reverse Your local gas generation partner Description Producing between 10 and 520 L/min of high purity nitrogen gas, Infinity XE 50 series gas…
Key words
lbs, lbspreventative, preventativenitrogen, nitrogenscientific, scientificmaintenance, maintenancerequirement, requirementmax, maxpeak, peakexternal, externalfcc, fcccompressors, compressorstried, triedinches, inchesair, airaftercare
Infinity 50 Series Site Preparation Guide
Infinity 50 Series Site Preparation Guide
2014|Peak Scientific|Manuals
Infinity 50 Series Site Preparation Guide 2014 © Peak Scientific - Rev. 0 – 17/04/14 Infinity 50* Site Preparation Guide Contents Page 2 Customer Responsibilities 3 Change History 4 Related Manuals 4 Safety Notices 5 Symbols 5 Safety Notice to…
Key words
generator, generatorscientific, scientificmaximum, maximumpeak, peaktubing, tubingspace, spacesite, siterequirements, requirementselectrical, electricalunpacking, unpackingminimum, minimuminlet, inletlbs, lbsair, airoutlets
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike