Infinity 1031 - 1034 - Nitrogen/Dry Air Generator for Sciex Mass Spectrometers
Brochures and specifications | 2020 | Peak ScientificInstrumentation
The availability of a reliable source of high-purity nitrogen and dry air is critical for maintaining the performance and throughput of LC-MS systems. On-site gas generation offers cost savings, minimized downtime, and improved lab safety compared to cylinder supplies.
This summary reviews the design, performance specifications, and operational benefits of the Peak Scientific Infinity 1031–1034 nitrogen/dry air generators. Key goals included evaluating flow capacities, ease of integration, and maintenance requirements across the four models.
The Infinity series employs membrane separation technology to produce one stream of laboratory-grade nitrogen and two streams of dry air. Models differ by maximum output flow rates tailored to specific LC-MS demands. The generators contain no moving parts, operate silently, and interface with external compressors or prefiltration systems when needed.
The Infinity generators support multiple LC-MS instruments, ensuring uninterrupted workflows and eliminating cylinder changeovers. Their modular design and on-demand operation enable flexible scheduling and reduced operational costs.
Advances in membrane materials may further enhance purity and efficiency. Integration with remote monitoring and predictive maintenance platforms will optimize uptime. Expansion to other analytical techniques could broaden application scopes.
The Peak Scientific Infinity 1031–1034 series offers a robust, low-maintenance solution for laboratory gas needs, delivering consistent performance and operational efficiency for modern LC-MS applications.
Laboratory gases and gas generators
IndustriesManufacturerPeak Scientific
Summary
Importance of the Topic
The availability of a reliable source of high-purity nitrogen and dry air is critical for maintaining the performance and throughput of LC-MS systems. On-site gas generation offers cost savings, minimized downtime, and improved lab safety compared to cylinder supplies.
Objectives and Study Overview
This summary reviews the design, performance specifications, and operational benefits of the Peak Scientific Infinity 1031–1034 nitrogen/dry air generators. Key goals included evaluating flow capacities, ease of integration, and maintenance requirements across the four models.
Methodology and Instrumentation Used
The Infinity series employs membrane separation technology to produce one stream of laboratory-grade nitrogen and two streams of dry air. Models differ by maximum output flow rates tailored to specific LC-MS demands. The generators contain no moving parts, operate silently, and interface with external compressors or prefiltration systems when needed.
Key Results and Discussion
- Flow capacities range from 10 to 76 L/min of nitrogen, with corresponding source gas flows up to 104 L/min.
- Operating pressure maintained at 8.27–10.0 bar (120–145 psi) with minimal pressure drop.
- Effective operation within 5–30 °C without additional electrical requirements.
- On-demand 24/7 gas supply with minimal maintenance due to few moving parts.
- Silent operation and compact footprint support diverse laboratory environments.
Benefits and Practical Applications
The Infinity generators support multiple LC-MS instruments, ensuring uninterrupted workflows and eliminating cylinder changeovers. Their modular design and on-demand operation enable flexible scheduling and reduced operational costs.
Future Trends and Potential Applications
Advances in membrane materials may further enhance purity and efficiency. Integration with remote monitoring and predictive maintenance platforms will optimize uptime. Expansion to other analytical techniques could broaden application scopes.
Conclusion
The Peak Scientific Infinity 1031–1034 series offers a robust, low-maintenance solution for laboratory gas needs, delivering consistent performance and operational efficiency for modern LC-MS applications.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Genius 1024 Nitrogen/Dry Air Generator for Sciex Mass Spectrometers
2020|Peak Scientific|Brochures and specifications
Genius 1024 Nitrogen/Dry Air Generator for Part Number : 99-9999 Service Kit : 99-9999 Sciex Mass Spectrometers Your local gas generation partner Description Designed exclusively to meet the needs of SCIEX LC-MS systems and approved by SCIEX for use with…
Key words
sciex, sciexair, airdry, drygas, gasmaintenance, maintenancegenerator, generatorcurtain, curtainmax, maxpreventative, preventativeexhaust, exhaustnitrogen, nitrogenplan, plannone, nonespectrometers, spectrometersruo
Infinity NM18-32L - Nitrogen Generator for Mass Spectrometers
2017|Peak Scientific|Brochures and specifications
Infinity NM18-32L Nitrogen Generator for Mass Spectrometers Part Number : 99-9999 Service Kit : 99-9999 Your local gas generation partner Description With 18L/min and 32L/min nitrogen producing models, the Infinity NM range can provide the high purity nitrogen gas for…
Key words
max, maxnitrogen, nitrogenmaintenance, maintenancegenerator, generatorgenerators, generatorsplan, planair, airgas, gasnone, noneinlet, inletdew, dewscientific, scientificmin, minminimal, minimalpressure
Gas Generators For SCIEX Systems
2019|Peak Scientific|Brochures and specifications
Your local gas generation partner Gas Generators For SCIEX Systems SCIEX approved vendor Discover more at www.peakscientific.com/sciex Our story The Peak way D E SCR I P TIO N Peak Scientific is a leading innovator in the design, manufacture and…
Key words
scr, scrgas, gasnitrogen, nitrogenhxwxd, hxwxdproduct, productsciex, sciexgenerator, generatorair, airtio, tiodry, drycompressor, compressorour, oursolaris, solarisbench, benchyour
Mass Spectrometer Table for Sciex LC-MS instruments
2017|Peak Scientific|Brochures and specifications
Mass Spectrometer Table for Sciex LC-MS instruments Part Number : 99-9999 Service Kit : 99-9999 Your local gas generation partner Description The MS table has been designed as a Sciex exclusive product to house the Triple Quad™, QTRAP™ or IVD…
Key words
none, nonesciex, sciexmax, maxtable, tablegenerator, generatoroutlets, outletsmaintenance, maintenanceplan, plangas, gasmaximum, maximumspectrometer, spectrometerscientific, scientificdimensions, dimensionshxwxd, hxwxdivd