MassHunter Study Manager for Ultivo LC/TQ - Quick Start Guide
Manuals | 2017 | Agilent TechnologiesInstrumentation
MassHunter Study Manager for Ultivo LC/TQ offers an integrated solution to automate sample queue creation, execution and result handling for high-throughput liquid chromatography–tandem quadrupole mass spectrometry. By grouping samples and operations into standardized “studies,” laboratories can minimize manual intervention, improve data consistency and ensure compliance with industry workflows.
The guide aims to introduce users to the Study Manager interface, describe how to configure study types (Worklist-Only, Worklist Import, Bioanalysis, Optimizer Automation), and demonstrate submission, execution and post-run tasks. Step-by-step exercises cover initial setup, study creation, queue management and result review.
The software interfaces with an Agilent Ultivo LC/TQ system via the MassHunter Workstation Data Acquisition program. Key components include:
Users can queue multiple studies, monitor real-time status, stop or resume runs on error, and reorder pending tasks. The interface logs each step, offers console locking for secure acquisition, and supports standby scripts for idle periods.
Implementing Study Manager accelerates method validation, routine QC, bioanalytical workflows and automated instrument optimization. Centralized study folders keep methods, worklists, data and reports together, simplifying audit trails and laboratory information management system (LIMS) integration.
Advances may include cloud-based queue monitoring, AI-driven error resolution, further LIMS connectivity and expanded support for hybrid MS platforms. Enhanced compliance logging and real-time reporting dashboards will meet evolving regulatory demands.
MassHunter Study Manager for Ultivo LC/TQ delivers a unified framework for streamlined LC/TQ operations, reducing hands-on time, enhancing reproducibility and facilitating large-scale sample analyses in regulated and research environments.
LC/MS, LC/MS/MS, LC/QQQ
IndustriesManufacturerAgilent Technologies
Summary
Importance of the topic
MassHunter Study Manager for Ultivo LC/TQ offers an integrated solution to automate sample queue creation, execution and result handling for high-throughput liquid chromatography–tandem quadrupole mass spectrometry. By grouping samples and operations into standardized “studies,” laboratories can minimize manual intervention, improve data consistency and ensure compliance with industry workflows.
Objectives and Study Overview
The guide aims to introduce users to the Study Manager interface, describe how to configure study types (Worklist-Only, Worklist Import, Bioanalysis, Optimizer Automation), and demonstrate submission, execution and post-run tasks. Step-by-step exercises cover initial setup, study creation, queue management and result review.
Methodology and Instrumentation
The software interfaces with an Agilent Ultivo LC/TQ system via the MassHunter Workstation Data Acquisition program. Key components include:
- Home and Settings Ribbons for queue control and error handling
- Study Wizards to import or generate worklists from text, XML or Excel templates
- Automated plate assignment and file naming rules
- Optional Quantitative Analysis integration and report generation
Main Results and Discussion
Users can queue multiple studies, monitor real-time status, stop or resume runs on error, and reorder pending tasks. The interface logs each step, offers console locking for secure acquisition, and supports standby scripts for idle periods.
Benefits and Practical Applications
Implementing Study Manager accelerates method validation, routine QC, bioanalytical workflows and automated instrument optimization. Centralized study folders keep methods, worklists, data and reports together, simplifying audit trails and laboratory information management system (LIMS) integration.
Future Trends and Potential Applications
Advances may include cloud-based queue monitoring, AI-driven error resolution, further LIMS connectivity and expanded support for hybrid MS platforms. Enhanced compliance logging and real-time reporting dashboards will meet evolving regulatory demands.
Conclusion
MassHunter Study Manager for Ultivo LC/TQ delivers a unified framework for streamlined LC/TQ operations, reducing hands-on time, enhancing reproducibility and facilitating large-scale sample analyses in regulated and research environments.
Used Instrumentation
- Agilent Ultivo LC/TQ liquid chromatography–tandem quadrupole MS system
- Agilent MassHunter Workstation Study Manager and Data Acquisition software
- Agilent Quantitative Analysis and Reporting modules (optional)
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
MassHunter Study Manager - Quick Start Guide
2018|Agilent Technologies|Manuals
MassHunter Study Manager Quick Start Guide What is MassHunter Study Manager? 2 Help 2 User Interface 3 Home tab on the ribbon 4 Settings tab on the ribbon 5 Current/Stopped Study Pane 7 Pending Studies tab 7 Completed Studies tab…
Key words
study, studyworklist, worklistmanager, managermasshunter, masshunterwizard, wizardstart, startguide, guidequick, quickpending, pendingsubmit, submitimport, importqueue, queuestudies, studiesclick, clicksubmitting
MassHunter Study Manager for K6460 and K6420 - Quick Start Guide
2018|Agilent Technologies|Manuals
MassHunter Study Manager for K6460 and K6420 Quick Start Guide For In Vitro Diagnostic Use The K6460 and K6420 mass spectrometers are intended to be used to identify inorganic or organic compounds in human specimens by ionizing the compounds and…
Key words
worklist, workliststudy, studywizard, wizardpending, pendingimport, importqueue, queueclick, clicksubmit, submitstudies, studiessubmitting, submittingpage, pageoptional, optionalexercise, exercisebioanalysis, bioanalysisfamiliarization
Agilent MassHunter Study Manager Software - Quick Start Guide
2010|Agilent Technologies|Manuals
Agilent MassHunter Study Manager Software Quick Start Guide What is MassHunter Study Manager Software? 2 Help 2 Documents 2 User Interface 3 Home Tab in the Ribbon 4 Settings Tab in the Ribbon 6 Current/Stopped Study Pane 8 Pending Studies…
Key words
study, studyworklist, worklistmanager, managerguide, guidestart, startquick, quickwizard, wizardagilent, agilentpending, pendingclick, clicksoftware, softwarequeue, queuesubmit, submitstudies, studiesyou
Agilent MassHunter Study Manager - Quick Start Guide
2012|Agilent Technologies|Manuals
Agilent MassHunter Study Manager Quick Start Guide What is MassHunter Study Manager? 2 Help 2 Documents 2 User Interface 3 Home Tab in the Ribbon 4 Settings Tab in the Ribbon 6 Current/Stopped Study Pane 8 Pending Studies Tab 8…
Key words
study, studyworklist, worklistmanager, managerguide, guidestart, startquick, quickwizard, wizardagilent, agilentpending, pendingsubmit, submitimport, importclick, clickqueue, queuestudies, studiespage