Perchlorate in Soil and Non-Potable Water by LC-MS/MS: A Tool for Tracking Occurrence in the Environment
Posters | 2020 | ShimadzuInstrumentation
LC/MS, LC/MS/MS, LC/QQQ
IndustriesEnvironmental
ManufacturerShimadzu
Key wordsprebias, min, perchlorate, intensity, dev, relative, value, time, mdlr, retention, std, calibration, mdlc, soil, recovery, temperature, flow, mean, reagent, samples, sample, blind, curve, receiving, optimized, precision, gradient, interested, conditions, standardization, avg, feedback, gas, run, desolvation, nebulizing, acceptance, serial, agency, ten, water, block, lcms, performance, acknowledgements, dwell, theoretical, transition, reporting, ppb
Similar PDF
Determination of chlorate and perchlorate in powdered infant formula using ion chromatography-mass spectrometry
2020|Thermo Fisher Scientific|Applications
APPLICATION NOTE 73854 Determination of chlorate and perchlorate in powdered infant formula using ion chromatography-mass spectrometry Authors: Beibei Huang and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA Keywords: Integrion HPIC, Dionex IonPac AS20 column, ISQ EC single quadrupole mass spectrometer,…
Key words
chlorate, chlorateperchlorate, perchlorateinfant, infantmean, meanistd, istdisq, isqformula, formulafinish, finishvalve, valveeluent, eluentmes, mesnegative, negativedionex, dionexmass, massauxilliary
Excellent choices for environmental applications - Water
2009|Agilent Technologies|Guides
Solutions that meet your demands for: speed accuracy productivity Excellent choices for environmental applications Water Volatiles Applications > Return to Table of Contents > Search entire document Ultra-Fast Total Petroleum Hydrocarbons (TPH) Analysis with Agilent Low Thermal Mass (LTM) GC…
Key words
icp, icpwater, wateragilent, agilenttime, timesample, samplewere, weremsd, msdcolumn, columnanalysis, analysismass, massgas, gasusa, usamethod, methodmode, modeused
PFAS Analysis: Application Notebook
2020|Shimadzu|Guides
PFAS Analysis: Application Notebook Solutions for PFAS Analysis Application Notebook Per- and polyfluoroalkyl substances (PFAS) are currently of great public health and environmental concern. Because PFAS are ubiquitous and commonly used in materials routinely employed for chemical analysis, laboratories are…
Key words
pfas, pfaspfos, pfospfoa, pfoaetfosaa, etfosaamefosaa, mefosaapfda, pfdapfuna, pfunapfdoa, pfdoapfhxa, pfhxapftria, pftriapfhxs, pfhxspfbs, pfbspftrea, pftreapfhpa, pfhpapfna
Determination of perchlorate by U.S. EPA Method 332.0 using a compact ion chromatography system coupled with mass spectrometry
2018|Thermo Fisher Scientific|Applications
APPLICATION NOTE 72587 Determination of perchlorate by U.S. EPA Method 332.0 using a compact ion chromatography system coupled with mass spectrometry Authors Beibei Huang and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA Goal To identify and quantitate trace levels…
Key words
perchlorate, perchloratemrl, mrlcalibration, calibrationccc, cccconcentration, concentrationdionex, dionexfortified, fortifiedlrb, lrbisq, isqcounts, countsdemonstration, demonstrationlfbs, lfbslfssms, lfssmsonguard, onguardlfssm