Impurity Analysis in Pharmaceutical Products with the Advanced Photodiode Array Detector SPD-M40
Applications | 2019 | ShimadzuInstrumentation
Controlled quantification of trace impurities in pharmaceutical products is critical to ensure patient safety and regulatory compliance. International Council for Harmonisation guidelines set strict thresholds for impurity levels, requiring identification and safety evaluation when individual impurities exceed 0.1% of the active ingredient.
This study evaluates the performance of a high-sensitivity photodiode array detector, SPD-M40, for impurity analysis in pharmaceuticals. Using ketoprofen as a model nonsteroidal anti-inflammatory drug, linearity, reproducibility, peak purity, and spectral confirmation of low-level impurities were assessed.
Chromatographic separation was achieved on a Shim-pack Velox C18 column (100 mm × 3.0 mm, 2.7 µm) with a low-pressure gradient of 10 mM sodium phosphate buffer (pH 2.6) and acetonitrile, at a flow rate of 1 mL/min and column temperature of 40 °C. Injection volume was 2 µL. The SPD-M40 detector, operating at 256 nm, features Advanced TC-Optics for triple temperature control of cell, light source, and optics, enabling a stable baseline and minimizing stray-light effects.
Linearity of ketoprofen was demonstrated over a wide concentration range (0.5–800 mg/L) with R2 ≥ 0.999. Six replicate analyses of a 700 mg/L standard showed peak heights around 2.5 AU and relative standard deviations below 1% for the major impurity exceeding 0.1%. Peak purity assessment via PDA confirmed absence of co-eluting species within the ketoprofen peak, and UV spectra of minor impurities were clearly resolved at area percentages as low as 0.046%.
Integration of high-performance PDA detectors with high-resolution mass spectrometry may further improve structural elucidation of unknown impurities. Advances in microflow and ultrahigh-pressure liquid chromatography can reduce solvent consumption and analysis time. Automation and AI-driven data processing will streamline impurity profiling and support real-time release testing in pharmaceutical manufacturing.
The SPD-M40 photodiode array detector delivers robust, sensitive, and reproducible impurity analysis in pharmaceutical products. Its wide dynamic range, stable baseline, and PDA capabilities meet stringent ICH requirements and support accurate trace impurity quantification.
HPLC
IndustriesPharma & Biopharma
ManufacturerShimadzu
Summary
Importance of the Topic
Controlled quantification of trace impurities in pharmaceutical products is critical to ensure patient safety and regulatory compliance. International Council for Harmonisation guidelines set strict thresholds for impurity levels, requiring identification and safety evaluation when individual impurities exceed 0.1% of the active ingredient.
Objectives and Study Overview
This study evaluates the performance of a high-sensitivity photodiode array detector, SPD-M40, for impurity analysis in pharmaceuticals. Using ketoprofen as a model nonsteroidal anti-inflammatory drug, linearity, reproducibility, peak purity, and spectral confirmation of low-level impurities were assessed.
Methodology and Instrumentation
Chromatographic separation was achieved on a Shim-pack Velox C18 column (100 mm × 3.0 mm, 2.7 µm) with a low-pressure gradient of 10 mM sodium phosphate buffer (pH 2.6) and acetonitrile, at a flow rate of 1 mL/min and column temperature of 40 °C. Injection volume was 2 µL. The SPD-M40 detector, operating at 256 nm, features Advanced TC-Optics for triple temperature control of cell, light source, and optics, enabling a stable baseline and minimizing stray-light effects.
Main Results and Discussion
Linearity of ketoprofen was demonstrated over a wide concentration range (0.5–800 mg/L) with R2 ≥ 0.999. Six replicate analyses of a 700 mg/L standard showed peak heights around 2.5 AU and relative standard deviations below 1% for the major impurity exceeding 0.1%. Peak purity assessment via PDA confirmed absence of co-eluting species within the ketoprofen peak, and UV spectra of minor impurities were clearly resolved at area percentages as low as 0.046%.
Benefits and Practical Applications of the Method
- Wide dynamic range up to 2.5 AU for accurate quantification from trace to high concentrations
- Low baseline noise and high sensitivity for reliable detection of low-level impurities
- Excellent reproducibility suited for quality control and regulatory submissions
- PDA-based peak purity and spectral confirmation enhance confidence in impurity identification
Future Trends and Opportunities
Integration of high-performance PDA detectors with high-resolution mass spectrometry may further improve structural elucidation of unknown impurities. Advances in microflow and ultrahigh-pressure liquid chromatography can reduce solvent consumption and analysis time. Automation and AI-driven data processing will streamline impurity profiling and support real-time release testing in pharmaceutical manufacturing.
Conclusion
The SPD-M40 photodiode array detector delivers robust, sensitive, and reproducible impurity analysis in pharmaceutical products. Its wide dynamic range, stable baseline, and PDA capabilities meet stringent ICH requirements and support accurate trace impurity quantification.
References
- ICH guidance on impurities in new drug substances (2002, Notification No. 1216001).
- ICH guidance on impurities in drug products (2003, Notification No. 0624001).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Impurity Analysis in Pharmaceutical Products with the Advanced Photodiode Array Detector SPD-M40
2019|Shimadzu|Applications
LAAN-A-LC-E311 Application News No. L538 High Performance Liquid Chromatography Impurity Analysis in Pharmaceutical Products with the Advanced Photodiode Array Detector SPD-M40 Impurities in pharmaceuticals must be appropriately controlled to ensure product safety. The ICH guidelines on impurities in pharmaceutical substances…
Key words
ketoprofen, ketoprofenimpurity, impuritymau, mauimpurities, impuritiespeak, peakpharmaceutical, pharmaceuticalarea, areamin, minheight, heightnews, newsmain, mainpurity, purityvelox, veloxstray, strayzoomed
Ultra High Performance Liquid Chromatograph Shimadzu Nexera series - Technical Reports / Applications
2020|Shimadzu|Guides
C190-E256 Ultra High Performance Liquid Chromatograph Nexera series Technical Reports / Applications The Nexera Series: Reinvent Your Workflow Just as the internet and smartphones have changed our lifestyles, and robots with AI capabilities continue to make our lives more convenient,…
Key words
acid, acidmau, mauanalysis, analysismobile, mobilemin, mincolumn, columnphase, phaseshim, shimnexera, nexerainjection, injectionpack, packorganic, organicatp, atpacids, acidspantothenate
Improvement of pharmaceutical impurity analysis by reducing the effects of stray light and room temperature fluctuations on PDA detector
2020|Shimadzu|Posters
Improvement of pharmaceutical impurity analysis by reducing the effects of stray light and room temperature fluctuations on PDA detector Takato Uchikata1, Satoshi Akita1, Hidetoshi Terada1, Masato Watanabe1, Keiko Matsumoto1; 1Shimadzu Corporation, Kyoto, Japan 1. Introduction A photodiode array detector (PDA)…
Key words
pda, pdafluctuations, fluctuationsimpurity, impuritystray, strayketoprofen, ketoprofenbaseline, baselineabsorbance, absorbancetemperaturecontrolled, temperaturecontrolledtemperature, temperaturepharmaceutical, pharmaceuticallight, lightindispensable, indispensabledetection, detectionnon, nonphotodiode
Automation and Efficiency Improvement Solutions (HPLC and LC-MS)
2025|Shimadzu|Brochures and specifications
C190-E340 Automation and Efficiency Improvement Solutions (HPLC and LC-MS) HPLC/LC-MS Analysis Workflow Just as robots equipped with AI functionality are offering major changes to our lives, continuous advancements in Shimadzu HPLC, LC-MS, data analysis software, and pretreatment systems are significantly…
Key words
flp, flpconditions, conditionspreparative, preparativeautomatic, automaticgradient, gradientoptimization, optimizationresolution, resolutionlabsolutions, labsolutionsmin, minmobile, mobilenexera, nexeraanalysis, analysisanalytical, analyticalautomatically, automaticallyphase