Shimadzu LCMS-2020 Liquid Chromatograph Mass Spectrometer

Brochures and specifications | 2012 | ShimadzuInstrumentation
LC/MS, LC/SQ
Industries
Manufacturer
Shimadzu

Summary

Importance of the Topic


High-throughput liquid chromatography–mass spectrometry (LC–MS) plays a crucial role in fields such as pharmaceutical development, clinical diagnostics, environmental monitoring and food safety. Rapid, sensitive detection of multiple analytes within very short chromatographic runs helps laboratories meet growing demands for speed without compromising data quality.

Objectives and Overview of the Study


The analyzed application note introduces the Shimadzu LCMS-2020 system, focusing on its ultra-fast (UF) measurement capabilities. Key goals include demonstrating high-speed mass detection, rapid polarity switching, and robust performance when analyzing complex or “dirty” samples under aggressive injection schedules.

Methodology


The study evaluates three proprietary UF functions: UFscanning (15,000 u/sec scan rate), UFswitching (15 ms polarity ionization switching), and UFsensitivity (enhanced ion optics and Qarray®). Performance tests involve:
  • Monitoring scan speed and polarity-change timing under alternating positive/negative ion modes.
  • Assessing sensitivity, linearity and repeatability via calibration curves over relevant concentration ranges.
  • Challenging system robustness through 2,500 sequential injections of acetonitrile-precipitated plasma (1 L each) over ten days.

Used Instrumentation


  • Shimadzu LCMS-2020 liquid chromatograph–mass spectrometer
  • UFscanning and UFswitching control software modules
  • New ion optical system with Qarray® ion guide
  • DL capillary desolvation line, removable under vacuum for maintenance

Main Results and Discussion


  • Scan Performance: Consistent 15,000 u/sec scan rate supports sub-minute analyses with minimal data loss.
  • Polarity Switching: Reliable 15 ms transitions enable seamless alternation between positive and negative ion modes.
  • Sensitivity and Linearity: Calibration curves exhibit excellent linearity and low limits of detection, even in ultra-fast gradients.
  • Robustness: Over 2,500 injections of complex plasma yielded a peak area RSD of 2.26%, confirming system durability.
  • Maintenance Efficiency: The vacuum-installable DL capillary streamlines desolvation line replacement without breaking vacuum.

Benefits and Practical Applications of the Method


Rapid, high-sensitivity LC–MS analysis accelerates workflows in drug metabolism studies, clinical screening, forensic toxicology and environmental pollutant monitoring. Reduced cycle times increase sample throughput, while robust design lowers downtime and maintenance costs.

Future Trends and Applications


  • Integration with automated sampling for 24/7 analysis in high-throughput laboratories.
  • Coupling ultra-fast MS with AI-driven data processing for real-time decision support.
  • Expansion of UF techniques to novel ionization sources and high-resolution mass analyzers.

Conclusion


The Shimadzu LCMS-2020 system demonstrates that ultra-fast scanning, rapid polarity switching and enhanced sensitivity can be combined in a robust platform. Such capabilities support accelerated, reliable analyses across diverse applications, meeting the evolving needs of modern analytical laboratories.

Reference


Shimadzu Corporation. LCMS-2020 Liquid Chromatograph Mass Spectrometer Application Note, 2012.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
LCMS-2020 - Reduces Limitations of HPLC Analysis and UFLC Analysis
C146-E125 LCMS-2020 - Reduces Limitations of HPLC Analysis and UFLC Analysis Technical Repor t vol.19 1. Need f or Ult ra- Fast Analysis One of the biggest issues for HPLC is faster analysis, and this requirement is being addressed with…
Key words
ultra, ultraspeed, speedufscanning, ufscanninglimitations, limitationsufswitching, ufswitchingmeasurement, measuremention, ionpositive, positiveswitching, switchingufsensitivity, ufsensitivitypolarity, polarityuflc, uflcfast, fastnegative, negativeanalysis
Shimadzu LCMS-2020
Shimadzu LCMS-2020
2021|Shimadzu|Brochures and specifications
C146-E121G Liquid Chromatograph Mass Spectrometer LCMS-2020 LCMS-2020 —Seeing is Believing. Ultra Fast UFswitching™ Rapid 15 msec Polarity Switching Ultra Fast UFsensitivity™ Superior Sensitivity with UHPLC Ultra Fast UFscanning™ 15,000 u/sec Fast Scanning Speed Speed is Power. Greater speed. Greater sensitivity.…
Key words
ufscanning, ufscanningultra, ultraerythromycin, erythromycinufswitching, ufswitchingpositive, positivedymuron, dymuronfast, fastcid, cidbrowser, browserswitching, switchingpurification, purificationnegative, negativeion, iondisplays, displaysdata
Shimadzu Liquid Chromatograph Mass Spectrometer LCMS-8050
Shimadzu Liquid Chromatograph Mass Spectrometer LCMS-8050
2019|Shimadzu|Brochures and specifications
C146-E232F Liquid Chromatograph Mass Spectrometer LCMS-8050 Speed and Sensitivity Beyond Comparison Continuing the evolution of Shimadzu's UF technology, Shimadzu introduces the LCMS-8050 triple quadrupole mass spectrometer, offering unparalleled measurement speeds and high-sensitivity performance. High-sensitivity quantitation delivered at high speed Multi-component…
Key words
switching, switchingufswitching, ufswitchingmrm, mrmufsensitivity, ufsensitivityufscanning, ufscanningspeed, speedhigh, highlabsolutions, labsolutionsufsweeper, ufsweepermpp, mppinsight, insightnexera, nexerapolarity, polarityeven, evenquantitative
Shimadzu Liquid Chromatograph Mass Spectrometer LCMS-8050
Shimadzu Liquid Chromatograph Mass Spectrometer LCMS-8050
2021|Shimadzu|Brochures and specifications
C146-E232G Liquid Chromatograph Mass Spectrometer LCMS-8050 Speed and Sensitivity Beyond Comparison Continuing the evolution of Shimadzu’s UF technology, Shimadzu introduces the LCMS-8050 triple quadrupole mass spectrometer, offering unparalleled measurement speeds and high-sensitivity performance. High-sensitivity quantitation delivered at high speed Multi-component…
Key words
ufswitching, ufswitchingswitching, switchingmrm, mrmufsensitivity, ufsensitivityufscanning, ufscanningspeed, speedhigh, highmpp, mpppolarity, polarityion, ionufsweeper, ufsweeperquantitative, quantitativesensitivity, sensitivitynegative, negativeeven
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike