Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy

Presentations | 2019 | ShimadzuInstrumentation
LC/TOF, LC/HRMS, LC/MS, LC/MS/MS
Industries
Manufacturer
Shimadzu

Summary

Significance of the Topic


The Q-TOF LC/MS technology is critical for applications requiring sub-ppm mass accuracy, high sensitivity and speed across fields such as pharmaceutical analysis, environmental monitoring and proteomics. Stable mass measurement enhances confidence in molecular identification and quantitation, supporting non-targeted screening and regulatory compliance.

Objectives and Study Overview


This study aims to examine key factors influencing mass accuracy, demonstrate performance of the Shimadzu LCMS-9030 QTOF under temperature fluctuations and evaluate its long-term stability for sub-ppm mass error without internal lock-mass correction.

Used Instrumentation


  • Shimadzu LCMS-9030 Q-TOF
  • Mass resolution: 30,000 FWHM at m/z 1972
  • Mass accuracy: <1 ppm at m/z 622.5662
  • Stability: 1 ppm over 24 h at 18–28 °C

Methodology


Performance was assessed using theoretical and experimental considerations of mass resolution, accuracy and ion statistics. Temperature-stress tests were conducted by cycling ±3 °C over 24 h, monitoring mass drift for model compounds. A 60-h stability test involved hourly injections under a single external calibration. Statistical evaluation used mean mass error and standard deviation across replicates.

Main Results and Discussion


  • Temperature Stress Test: Mass drift remained below 1.5 ppm for ±3 °C variations solely with external calibration.
  • 60-h Stability: Continuous operation without recalibration yielded mean mass errors near zero and standard deviations under 0.2 ppm across positive and negative modes.
  • Theoretical Ion Statistics: Demonstrated resolution-dependent precision limits, showing that 30,000 resolution and sufficient ion counts predict sub-ppm accuracy.
  • Mass Accuracy Triangle: Emphasized balanced resolution, sensitivity and stability to achieve reliable measurements.
  • Data Utilization: High-accuracy data enabled non-targeted pesticide screening in green tea extracts, structural formula prediction, and optimized extracted ion chromatograms.

Benefits and Practical Applications


  • Robust sub-ppm mass accuracy without lock-mass correction simplifies workflows.
  • Improved confidence in compound identification for targeted and non-targeted analyses.
  • High-precision quantitation with optimized XIC windows enhances signal-to-noise ratio.

Future Trends and Applications


Emerging developments include advanced thermal control algorithms, further integration of computational modeling for instrument design, real-time calibration strategies and expanded applications in metabolomics and environmental screening. Enhanced data processing tools and AI-driven spectral interpretation will further leverage high-accuracy mass data.

Conclusion


The Shimadzu LCMS-9030 QTOF demonstrates exceptional mass accuracy stability, achieving <1 ppm error over extended periods without internal correction. Balanced instrument design, combining high resolution, sensitivity and temperature-controlled stability, supports reliable high-confidence analyses in diverse applications. Statistical metrics such as standard deviation provide robust benchmarks for performance.

Reference


  • Brenton AG, Godfrey AR. Terminology and Treatment of Accurate Mass Measurement Data. J Am Soc Mass Spectrom. 2010.
  • Ogi H, Yanagita R, et al. Observation of Thermal Modes in Objects. Phys Rev Lett. 2016;117:195901.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Shimadzu Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030
C146-E365B Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 Effortless Performance The LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world’ s fastest and most sensitive quadrupole technology with TOF architecture. A product of Shimadzu's engineering DNA, speed and effortless performance…
Key words
mma, mmaspectrum, spectrumflight, flightetizolam, etizolamquadrupole, quadrupolemass, massflighttube, flighttubeprobe, probemikros, mikroschromatograph, chromatographshimadzu, shimadzuspectrometer, spectrometerspectra, spectraufgrating, ufgratingvalinomycin
Shimadzu Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030
C146-E365C Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 Effortless Performance The LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world’ s fastest and most sensitive quadrupole technology with TOF architecture. A product of Shimadzu's engineering DNA, speed and effortless performance…
Key words
mma, mmaspectrum, spectrumetizolam, etizolamquadrupole, quadrupolemass, massflight, flightflighttube, flighttubeprobe, probemikros, mikroschromatograph, chromatographmicroflow, microflowshimadzu, shimadzuspectrometer, spectrometerspectra, spectraufgrating
On the Accurate Understanding of Mass Measurement Accuracy in Q-TOF MS
C10G-E073 WHITE PAPER On the Accurate Understanding of Mass Measurement Accuracy in Q-TOF MS High-resolution, accurate-mass (HRAM) mass spectrometers (MS) are a class of MS instrumentation with capability to resolve complex sample matrix and to allow identification of compounds by…
Key words
mass, masstof, tofpaper, paperwhite, whitemma, mmaunderstanding, understandinglock, lockcalibration, calibrationaccuracy, accuracyprobability, probabilityaccurate, accurateshimadzu, shimadzumeasurement, measurementppm, ppmfwmh
Imaging Mass Microscope iMScope QT
Imaging Mass Microscope iMScope QT
2025|Shimadzu|Brochures and specifications
C146-E415A Imaging Mass Microscope iMScope QT The One and Only Next-Generation Mass Spectrometry Imaging Created by iMScope™ QT Inheriting the concept of a mass spectrometer equipped with an optical microscope from the iMScope series, the iMScope QT is also Shimadzu’s…
Key words
imlayer, imlayerdeposition, depositionimscope, imscopeimaging, imagingmicroscope, microscopevapor, vaporaero, aeromma, mmaspray, sprayoptical, opticalimages, imagesmsi, msimass, massspraying, sprayingmatrix
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike