USEPA Procedures for Wastewater Analyses by Packed Column GC and HPLC
Guides | 1998 | MerckInstrumentation
Monitoring of organic priority pollutants in wastewater is critical for environmental protection and regulatory compliance. The USEPA methods enable sensitive and reliable detection of volatile and nonvolatile organic pollutants at trace levels, ensuring that industrial and municipal discharges meet national effluent standards and protect public health and ecosystems.
The bulletin reviews and consolidates USEPA procedures for analyzing 113 organic priority pollutants in wastewater. It outlines revised GC-MS methods (Methods 624, 625) and alternative GC and HPLC approaches (Methods 601–613). The aim is to present validated chromatographic columns, packing materials, traps for sample preconcentration, and detection systems that resolve and confirm the identity of pollutants across multiple chemical classes.
The analytical workflow comprises:
Key hardware includes packed-column and capillary GC systems equipped with stainless steel or fused silica columns (e.g., Carbopack™, SP™, OV™, SPB™, VOCOL™), purge-and-trap manifolds, solid-phase traps, HPLC pumps with reversed-phase columns (e.g., SUPELCOSIL™ LC-1, LC-PAH), and a range of detectors capable of sub-ppb sensitivity.
Revised packings exhibited improved deactivation, enhancing peak resolution and detection limits for challenging analytes. Chromatograms demonstrate complete class-specific separation of 113 pollutants in single analyses. The pairing of primary and confirmational columns increases confidence in identification, while capillary columns offer higher sample capacity, faster runs, and compatibility with purge-and-trap systems.
These USEPA-approved methods provide industries with flexible, validated analytical protocols for routine wastewater monitoring and regulatory reporting. The selection of GC-MS, GC, or HPLC allows laboratories to leverage existing equipment, ensuring cost-effectiveness. The high sensitivity and selectivity facilitate accurate quantification of pollutants at regulatory thresholds, supporting National Pollution Discharge Elimination System (NPDES) compliance.
Advancements may include broader adoption of capillary and wide-bore columns for faster, higher-capacity analyses, integration with hyphenated techniques (GC-FTIR, GC–MS/MS), automated sample handling, and portable systems for on-site monitoring. Methods may evolve to accommodate emerging contaminants and lower detection limits as regulatory requirements tighten.
The USEPA’s comprehensive suite of chromatographic methods and Supelco column packings provides robust, validated strategies for analyzing priority organic pollutants in wastewater. Their implementation supports environmental protection goals by ensuring reliable detection and quantification of contaminants at trace levels.
GC, GC columns, Consumables, HPLC, LC columns
IndustriesEnvironmental
ManufacturerMerck
Summary
Significance of the Topic
Monitoring of organic priority pollutants in wastewater is critical for environmental protection and regulatory compliance. The USEPA methods enable sensitive and reliable detection of volatile and nonvolatile organic pollutants at trace levels, ensuring that industrial and municipal discharges meet national effluent standards and protect public health and ecosystems.
Objectives and Study Overview
The bulletin reviews and consolidates USEPA procedures for analyzing 113 organic priority pollutants in wastewater. It outlines revised GC-MS methods (Methods 624, 625) and alternative GC and HPLC approaches (Methods 601–613). The aim is to present validated chromatographic columns, packing materials, traps for sample preconcentration, and detection systems that resolve and confirm the identity of pollutants across multiple chemical classes.
Methodology and Instrumentation
The analytical workflow comprises:
- Sample preconcentration: Purge-and-trap on solid adsorbents (e.g., Tenax, Silica Gel, SP-2100) for volatile analytes; solvent extraction (methylene chloride or chloroform) followed by Kuderna-Danish concentration and cleanup for nonvolatiles.
- Chromatographic separation: USEPA Method 624 (GC-MS) for volatiles; Method 625 (GC-MS) for acids, bases, neutrals, pesticides, and PCBs; GC Methods 601–604 for purgeable halocarbons, aromatics, acrolein/acrylonitrile, and phenols; GC Methods 606–613 for phthalates, nitrosamines, organochlorine pesticides, PCBs, nitroaromatics, PAHs, haloethers, chlorinated hydrocarbons, and TCDD; HPLC Methods 605 and 610 for benzidines and PAHs respectively.
- Detection techniques: Mass spectrometry for confirmation; flame ionization, electron capture, photoionization, Hall conductivity, and fluorescence detectors for routine screening.
Instrumentation Used
Key hardware includes packed-column and capillary GC systems equipped with stainless steel or fused silica columns (e.g., Carbopack™, SP™, OV™, SPB™, VOCOL™), purge-and-trap manifolds, solid-phase traps, HPLC pumps with reversed-phase columns (e.g., SUPELCOSIL™ LC-1, LC-PAH), and a range of detectors capable of sub-ppb sensitivity.
Main Results and Discussion
Revised packings exhibited improved deactivation, enhancing peak resolution and detection limits for challenging analytes. Chromatograms demonstrate complete class-specific separation of 113 pollutants in single analyses. The pairing of primary and confirmational columns increases confidence in identification, while capillary columns offer higher sample capacity, faster runs, and compatibility with purge-and-trap systems.
Benefits and Practical Applications
These USEPA-approved methods provide industries with flexible, validated analytical protocols for routine wastewater monitoring and regulatory reporting. The selection of GC-MS, GC, or HPLC allows laboratories to leverage existing equipment, ensuring cost-effectiveness. The high sensitivity and selectivity facilitate accurate quantification of pollutants at regulatory thresholds, supporting National Pollution Discharge Elimination System (NPDES) compliance.
Future Trends and Potential Applications
Advancements may include broader adoption of capillary and wide-bore columns for faster, higher-capacity analyses, integration with hyphenated techniques (GC-FTIR, GC–MS/MS), automated sample handling, and portable systems for on-site monitoring. Methods may evolve to accommodate emerging contaminants and lower detection limits as regulatory requirements tighten.
Conclusion
The USEPA’s comprehensive suite of chromatographic methods and Supelco column packings provides robust, validated strategies for analyzing priority organic pollutants in wastewater. Their implementation supports environmental protection goals by ensuring reliable detection and quantification of contaminants at trace levels.
Reference
- USEPA. Sampling and Analysis Procedures for Screening of Industrial Effluents for Priority Pollutants. EPA Effluent Guidelines Division, 1977.
- USEPA. Federal Register, Vol. 44, No. 233, Dec 3 1979.
- USEPA. Federal Register, Vol. 45, No. 98, May 19 1980.
- Bellar TA, Lichtenberg JJ. J Am Water Works Assoc. 1974;66:739–744.
- USEPA. Manual of Analytical Methods for the Analysis of Pesticides in Human and Environmental Samples. EPA-600/8-80-038, 1980.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Wastewater Standards - Your essential resource for Agilent ULTRA chemical standards
2019|Agilent Technologies|Brochures and specifications
Wastewater Standards Your essential resource for Agilent ULTRA chemical standards Table of contents Introduction 3 EPA Method 612 17 About Agilent standards 3 EPA Method 613 18 Products 3 EPA Method 614, 614.1 18 Markets 3 EPA Method 615 19…
Key words
description, descriptionanalytes, analytesmethylene, methylenechloride, chloridestandards, standardsmixture, mixturemethanol, methanolphthalate, phthalateepa, epaphwk, phwktclp, tclpwastewater, wastewaterbenzo, benzomixtures, mixturessurrogate
EPA Groundwater Standards - Your essential resource for Agilent ULTRA chemical standards
2019|Agilent Technologies|Brochures and specifications
EPA Groundwater Standards Your essential resource for Agilent ULTRA chemical standards Table of contents Introduction 3 EPA Method 8081B 18 About Agilent standards 3 EPA Method 8082A 19 Products 3 EPA Method 8091 20 Markets 3 EPA Method 8095 21…
Key words
description, descriptionanalytes, analytesstandards, standardsepa, epaphthalate, phthalatebenzo, benzodnph, dnphgroundwater, groundwatersurrogate, surrogatechloride, chloridemixture, mixturemethanol, methanolfluoranthene, fluoranthenexylene, xylenestandard
Soft ionization GC-HRMS of Polycyclic Aromatic Hydrocarbons (PAHs)
2020|Thermo Fisher Scientific|Applications
Application Note Soft ionization GC-HRMS of Polycyclic Aromatic Hydrocarbons (PAHs) Summary Experimental Setup We show the feasibilty of GC-SICRIT -HRMS for trace analysis of poylcyclic aromatic hydrocarbons. ® Introduction Polycyclic aromatic hydrocarbons (PAHs) are neutral, nonpolar organic molecules that comprise…
Key words
sicrit, sicritreserved, reservedrights, rightspah, pahfeasibilty, feasibiltymtheo, mtheoanthracene, anthracenepyrene, pyrenefluoranthene, fluoranthenepahs, pahsbenzo, benzohrms, hrmsdbd, dbdcarrier, carriertemperature
Supelco Columns for USP Methods
2014|Merck|Posters
Supelco Columns for USP Methods The official pharmaceutical analysis monographs in the United States Pharmacopeia (USP) detail the methods used by pharmaceutical manufacturers for quality control of bulk drug substances and dosage form preparations. Each method specifies a particular high…
Key words
supelcosil, supelcosilglycol, glycolchromosorb, chromosorbhayesep, hayesepastec, asteccopolymer, copolymersuccinate, succinatedivinylbenzene, divinylbenzeneascentis, ascentissupelcogel, supelcogelporapak, porapakresin, resinadipate, adipatebonded, bondedstyrene