LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Fast and Simple Protein Molecular Weight Confirmation Using the Agilent InfinityLab LC/MSD XT Mass Selective Detector

 

Similar PDF

Toggle
Application Note Pharma & Biopharma Critical Quality Attribute Monitoring of mAbs at the Intact and Subunit Levels Using a Cost-Effective, Simple and Robust LC/MS Solution Authors Linfeng Wu, Lisa Zang, and Guannan Li Agilent Technologies, Inc. Abstract Recombinant monoclonal antibodies…
Key words
mass, massnistmab, nistmabcounts, countsdeglycosylated, deglycosylatedintact, intactmsd, msdprotein, proteincharge, chargespectrum, spectrumdeconvoluted, deconvolutedglycoforms, glycoformsmabs, mabsresponse, responsenone, nonechemstation
Application Note Molecular Weight Confirmation of a Peptide Using MS Spectral Deconvolution for OpenLab CDS and the Agilent InfinityLab LC/MSD XT System Authors Abstract Simon Pfeiffer, Jarod Grossman, Brian Rivera Agilent Technologies, Inc. Intact mass analysis of proteins and peptides…
Key words
deconvolution, deconvolutionthreshold, thresholdspectral, spectralmolecular, molecularweight, weightmass, massmsd, msdconfirmation, confirmationinfinitylab, infinitylaboxidation, oxidationintact, intactagilent, agilentcds, cdsstorage, storageopenlab
Agilent BioHPLC Columns Characterization of NIST Monoclonal Antibody Critical Quality Attributes Application Compendium Contents Agilent-NISTmAb Standard (P/N 5191-5744; 5191-5745) was aliquoted from NISTmAb RM 8671 batch. Quality control (QC) testing is performed using Agilent LC-MS system. QC batch release test…
Key words
mab, mabglycan, glycanadvancebio, advancebiocounts, countsmapping, mappingpeptide, peptideagilent, agilentmonoclonal, monoclonalglycans, glycansmin, mincolumn, columnmass, massprotein, proteinnistmab, nistmabassaymap
Agilent-NISTmAb Peptide Mapping Agilent BioHPLC Columns Application Compendium Contents Agilent-NISTmAb Standard (P/N 5191-5744; 5191-5745) was aliquoted from NISTmAb RM 8671 batch. Quality control (QC) testing is performed using Agilent LC-MS system. QC batch release test includes aggregate profile, charge variants…
Key words
peptide, peptidemapping, mappingpage, pagecontents, contentsback, backadvancebio, advancebiocdr, cdrpeptides, peptidesagilent, agilentassaymap, assaymapmin, minmap, mapattributes, attributespqas, pqasmsd
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike