Chiral Analysis of Sulfur Amino Acids with Agilent InfinityLab Poroshell 120 Chiral-T Columns
Applications | 2019 | Agilent TechnologiesInstrumentation
The separation of chiral amino acids is critical in pharmaceutical development, nutritional analysis, and quality control. Sulfur-containing amino acids such as cysteine and methionine exist as enantiomeric pairs with distinct biological activities. Reliable, high-throughput methods for resolving these enantiomers support drug safety assessments, metabolic studies, and industrial processes.
This study evaluates the performance of an Agilent InfinityLab Poroshell 120 Chiral-T column for the enantioselective separation of underivatized cysteine and methionine. The goals were to achieve baseline resolution in a short analysis time using a mass spectrometry-compatible mobile phase and to demonstrate robust, reproducible performance on a superficially porous particle column.
Sample Preparation
Liquid chromatography system:
Both cysteine and methionine enantiomer pairs were baseline-separated in under four minutes. Key performance metrics:
Rapid, robust enantioseparation under common reversed-phase conditions allows integration into existing LC workflows. The method supports:
Advances in superficially porous chiral phases may extend to other amino acids and small biomolecules. Potential developments include:
The Agilent InfinityLab Poroshell 120 Chiral-T column delivers fast, high-resolution separation of sulfur-containing amino acid enantiomers using an MS-compatible mobile phase. Its robust performance and compatibility with standard LC infrastructure make it well suited for analytical laboratories in pharma, biopharma, and food science.
Consumables, HPLC, LC columns
IndustriesPharma & Biopharma
ManufacturerAgilent Technologies
Summary
Significance of the Topic
The separation of chiral amino acids is critical in pharmaceutical development, nutritional analysis, and quality control. Sulfur-containing amino acids such as cysteine and methionine exist as enantiomeric pairs with distinct biological activities. Reliable, high-throughput methods for resolving these enantiomers support drug safety assessments, metabolic studies, and industrial processes.
Objectives and Study Overview
This study evaluates the performance of an Agilent InfinityLab Poroshell 120 Chiral-T column for the enantioselective separation of underivatized cysteine and methionine. The goals were to achieve baseline resolution in a short analysis time using a mass spectrometry-compatible mobile phase and to demonstrate robust, reproducible performance on a superficially porous particle column.
Methodology
Sample Preparation
- Individual D- and L-enantiomers prepared at 2 mg/mL in water and mixed 1:1 to 1 mg/mL each.
- Column: Poroshell 120 Chiral-T, 2.1 × 100 mm, 2.7 µm.
- Mobile Phase: 70/30 methanol/25 mM ammonium formate buffer, pH 3.0.
- Flow Rate: 0.21 mL/min.
- Column Temperature: 30 °C.
- Injection Volume: 1 µL.
Instrumentation Used
Liquid chromatography system:
- Agilent 1290 Infinity II LC with low-dispersion connections.
- Flexible Pump, Infinity Autosampler, Multicolumn Thermostat.
- Evaporative Light Scattering Detector (ELSD) at 30 °C evaporator and nebulizer, 1 SLM gas flow, 40 Hz signal acquisition.
- OpenLab CDS software for data acquisition.
Main Results and Discussion
Both cysteine and methionine enantiomer pairs were baseline-separated in under four minutes. Key performance metrics:
- Cysteine: k1=0.86, k2=1.50, resolution Rs=4.31, selectivity α=1.75.
- Methionine: k1=0.84, k2=1.76, Rs=5.58, α=2.08.
Benefits and Practical Applications
Rapid, robust enantioseparation under common reversed-phase conditions allows integration into existing LC workflows. The method supports:
- Pharmaceutical enantiopurity testing.
- Metabolite profiling in biopharma research.
- Quality control of nutritional supplements.
Future Trends and Potential Applications
Advances in superficially porous chiral phases may extend to other amino acids and small biomolecules. Potential developments include:
- Coupling with high-resolution mass spectrometry for structural elucidation.
- Expansion to supercritical fluid chromatography (SFC) for green analysis.
- Miniaturized or high-throughput platforms for screening applications.
Conclusion
The Agilent InfinityLab Poroshell 120 Chiral-T column delivers fast, high-resolution separation of sulfur-containing amino acid enantiomers using an MS-compatible mobile phase. Its robust performance and compatibility with standard LC infrastructure make it well suited for analytical laboratories in pharma, biopharma, and food science.
References
- Agilent Technologies Application Note 5994-1381EN, Chiral Analysis of Sulfur Amino Acids with Agilent InfinityLab Poroshell 120 Chiral-T Columns, 2019.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Chiral Analysis of Hydrophobic Amino Acids with Agilent InfinityLab Poroshell 120 Chiral-T Column
2019|Agilent Technologies|Applications
Application Note Pharma & Biopharma Chiral Analysis of Hydrophobic Amino Acids with Agilent InfinityLab Poroshell 120 Chiral-T Column Author William J. Long Agilent Technologies, Inc. Abstract The chiral separation of a series of underivatized aliphatic amino acids was performed using…
Key words
chiral, chiralenantiomers, enantiomerslsu, lsuamino, aminoaliphatic, aliphaticacids, acidsseparation, separationporous, porousvaline, valineinteractions, interactionsisoleucine, isoleucineminutes, minutessuperficially, superficiallyalanine, alanineleucine
Chiral Analysis of Aromatic Amino Acids with Agilent InfinityLab Poroshell 120 Chiral-T Columns
2019|Agilent Technologies|Applications
Application Note Pharma & Biopharma Chiral Analysis of Aromatic Amino Acids with Agilent InfinityLab Poroshell 120 Chiral-T Columns Author William J. Long Agilent Technologies, Inc. Abstract The chiral separation of a series of underivatized aromatic amino acids was performed using…
Key words
amino, aminochiral, chiralmau, mauacids, acidslsu, lsumin, minphenylalanine, phenylalaninetryptophan, tryptophanporous, porouswere, wereenantiomers, enantiomersaromatic, aromaticunderivatized, underivatizedwavelength, wavelengthaliphatic
Modernizing Chiral Separations with Glycopeptide-Based Chiral Columns
2020|Agilent Technologies|Applications
Application Note Pharmaceutical Small Molecules Modernizing Chiral Separations with Glycopeptide-Based Chiral Columns Chiral separation of timolol maleate with Agilent InfinityLab Poroshell 120 Chiral-T columns Author William J. Long Agilent Technologies, Inc. Abstract In this application note, the development and optimization…
Key words
chiral, chiraltimolol, timololformate, formateammonium, ammoniumenantiomers, enantiomersglycopeptide, glycopeptideteicoplanin, teicoplaninmau, maumaleate, maleateionic, ionicseparations, separationspolar, polarphase, phasecsps, cspsseparation
Chiral Analysis of Sodium Lactate with Agilent InfinityLab Poroshell 120 Chiral-T Columns
2022|Agilent Technologies|Applications
Application Note Small Molecule Pharmaceuticals & Generics Chiral Analysis of Sodium Lactate with Agilent InfinityLab Poroshell 120 Chiral-T Columns Authors William J. Long and Carl Griffin Agilent Technologies, Inc. Introduction Faster separations of enantiomers have become increasingly important in biochemical…
Key words
chiral, chirallsu, lsulactate, lactatesodium, sodiuminteractions, interactionsmin, minrecognition, recognitionseparations, separationsformate, formateenantiomers, enantiomersammonium, ammoniumseparation, separationcompounds, compoundsphase, phaseresistant