Identification of Benzodiazepines and Their Metabolites Using Synchronized Survey Scan®
Applications | 2014 | ShimadzuInstrumentation
Accurate detection of benzodiazepines and their metabolites is essential in clinical toxicology, forensic investigations, and therapeutic drug monitoring. These compounds exhibit potent pharmacological effects and may lead to adverse events or dependency. High confidence in identification and quantification supports patient safety, legal evidence, and quality control in pharmaceutical manufacturing.
This study demonstrates a streamlined approach for simultaneous multiple reaction monitoring (MRM) and MS/MS spectral acquisition using the Shimadzu LCMS-8030 with Synchronized Survey Scan®. The primary objectives were:
Chromatographic separation employed a YMC Triart C18 column (2 mm I.D. × 150 mm, 1.9 µm) at 40 °C with a gradient elution of 10 mM formic acid in water (A) and a 50/50 mix of 10 mM formic acid in water/acetonitrile (B). The mobile phase gradient progressed from 40% B to 65% B over 40 minutes, then returned to 40% B by 40.01 minutes, holding until 60 minutes. Flow rate was 0.3 mL/min and injection volume 1 µL.
Synchronized Survey Scan enabled concurrent MRM quantitation and MRM-dependent product ion scanning for Etizolam, Triazolam, and four metabolites (α-hydroxy and 8-ethylhydroxy Etizolam; α- and 4-hydroxy Triazolam). Optimized collision energies ranged from –18 to –39 V depending on the transition. Chromatographic resolution was achieved within a 45-minute run, with clear baseline separation of parent drugs and metabolites.
Library search parameters including precursor m/z and polarity significantly improved identification accuracy. When parameters were enabled, false positives were reduced and correct spectral matches ranked highest. This approach ensures robust confirmation of target analytes in complex matrices.
Advances in high-speed triple quadrupole MS may enable real-time monitoring of drug metabolism in biological fluids. Integration with automated library updates and AI-driven spectral interpretation could further streamline forensic workflows. Expansion to other psychoactive compound classes or emerging designer drugs represents a promising direction for comprehensive, high-confidence screening platforms.
The Shimadzu LCMS-8030 with Synchronized Survey Scan® offers a powerful, efficient solution for simultaneous quantitation and structural confirmation of benzodiazepines and their metabolites. Optimized MRM transitions and library search strategies deliver reliable, high-throughput analysis suitable for clinical, forensic, and pharmaceutical quality control settings.
LC/MS, LC/MS/MS, LC/QQQ
IndustriesMetabolomics, Clinical Research
ManufacturerShimadzu
Summary
Importance of the Topic
Accurate detection of benzodiazepines and their metabolites is essential in clinical toxicology, forensic investigations, and therapeutic drug monitoring. These compounds exhibit potent pharmacological effects and may lead to adverse events or dependency. High confidence in identification and quantification supports patient safety, legal evidence, and quality control in pharmaceutical manufacturing.
Aims and Overview of the Study
This study demonstrates a streamlined approach for simultaneous multiple reaction monitoring (MRM) and MS/MS spectral acquisition using the Shimadzu LCMS-8030 with Synchronized Survey Scan®. The primary objectives were:
- To implement a single-run method combining high-sensitivity quantitation and product ion scanning for benzodiazepines and metabolites.
- To optimize collision energies for each analyte to maximize spectral quality.
- To validate library matching for reliable compound identification.
Methodology
Chromatographic separation employed a YMC Triart C18 column (2 mm I.D. × 150 mm, 1.9 µm) at 40 °C with a gradient elution of 10 mM formic acid in water (A) and a 50/50 mix of 10 mM formic acid in water/acetonitrile (B). The mobile phase gradient progressed from 40% B to 65% B over 40 minutes, then returned to 40% B by 40.01 minutes, holding until 60 minutes. Flow rate was 0.3 mL/min and injection volume 1 µL.
Used Instrumentation
- Liquid Chromatograph: Shimadzu Prominence UFLC XR
- Column: YMC Triart C18, 1.9 µm, 12 nm (2 mm I.D. × 150 mm)
- Mass Spectrometer: Shimadzu LCMS-8030 with Synchronized Survey Scan®
- Ion Source: ESI positive mode
Main Results and Discussion
Synchronized Survey Scan enabled concurrent MRM quantitation and MRM-dependent product ion scanning for Etizolam, Triazolam, and four metabolites (α-hydroxy and 8-ethylhydroxy Etizolam; α- and 4-hydroxy Triazolam). Optimized collision energies ranged from –18 to –39 V depending on the transition. Chromatographic resolution was achieved within a 45-minute run, with clear baseline separation of parent drugs and metabolites.
Library search parameters including precursor m/z and polarity significantly improved identification accuracy. When parameters were enabled, false positives were reduced and correct spectral matches ranked highest. This approach ensures robust confirmation of target analytes in complex matrices.
Benefits and Practical Applications
- Single-run analysis improves laboratory throughput by combining quantitation and confirmation steps.
- Enhanced sensitivity of MRM ensures low-level detection vital for toxicology screening.
- Library matching with specified precursor and polarity reduces misidentification risk.
- Flexible collision energy settings allow tailored spectral quality for diverse benzodiazepine structures.
Future Trends and Potential Applications
Advances in high-speed triple quadrupole MS may enable real-time monitoring of drug metabolism in biological fluids. Integration with automated library updates and AI-driven spectral interpretation could further streamline forensic workflows. Expansion to other psychoactive compound classes or emerging designer drugs represents a promising direction for comprehensive, high-confidence screening platforms.
Conclusion
The Shimadzu LCMS-8030 with Synchronized Survey Scan® offers a powerful, efficient solution for simultaneous quantitation and structural confirmation of benzodiazepines and their metabolites. Optimized MRM transitions and library search strategies deliver reliable, high-throughput analysis suitable for clinical, forensic, and pharmaceutical quality control settings.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Identification of triazolam, etizolam and their metabolites in biological samples by liquid chromatography tandem mass spectrometry
2012|Shimadzu|Posters
PO-CON1220E Identification of triazolam, etizolam and their metabolites in biological samples by liquid chromatography tandem mass spectrometry IMSC 2012 PTh-196 Mayumi Matsui1, Toshikazu Minohata1, Noriko Shoji2, Naohiro Kuriyama2, Chie Yokoyama2, Keiko Matsumoto1, Jun Watanabe1, Junko Iida1 1 Shimadzu Corporation, Kyoto,…
Key words
etizolam, etizolamalpha, alphatandem, tandemzolam, zolambiological, biologicalhydroxyetizolam, hydroxyetizolamhydroxytriazolam, hydroxytriazolampeaks, peaksmrm, mrmtriazolam, triazolamspectrometry, spectrometryliquid, liquidmetabolites, metabolitestriggered, triggeredchromatography
Identification of triazolam, etizolam and their metabolites in biological samples by liquid chromatography tandem mass spectrometry
2012|Shimadzu|Applications
Identification of triazolam, etizolam and their metabolites in biological samples by liquid chromatography tandem mass spectrometry ASMS 2012 WP28-611 Noriko Shoji1; Toshikazu Minohata2; Naohiro Kuriyama1; Chie Yokoyama1; Keiko Matsumoto2; Jun Watanabe2; Junko Iida2 1 YMC Co., LTD., Komatsu, JAPAN 2…
Key words
etizolam, etizolamalpha, alphazolam, zolamtandem, tandembiological, biologicalhydroxyetizolam, hydroxyetizolammrm, mrmmetabolites, metaboliteshydroxytriazolam, hydroxytriazolampeaks, peakstriazolam, triazolamspectrometry, spectrometrywere, wereliquid, liquidmass
Simultaneous Analysis of Etizolam, Triazolam, and Their Metabolites in Biospecimens Using LCMS™-9030
2019|Shimadzu|Applications
LAAN-A-LM-E153 Application News No. C183 Liquid Chromatography Mass Spectrometry Simultaneous Analysis of Etizolam, Triazolam, and Their Metabolites in Biospecimens Using LCMS™-9030 Introduction Instrument and Analysis Conditions Etizolam and Triazolam are psychotropic drugs in the benzodiazepine class, which are…
Key words
triazolam, triazolametizolam, etizolamalpha, alphahydroxy, hydroxyblood, bloodmin, minhydroxyetizolam, hydroxyetizolamwhole, wholeplasma, plasmapsychotropic, psychotropichydroxytriazolam, hydroxytriazolamxic, xicdetected, detectednews, newserrors
Fast polarity switching and MRM triggered automatic MS/MS applied to benzodiazepines and their metabolites in clinical and forensic analysis
2011|Shimadzu|Posters
Fast polarity switching and MRM triggered automatic MS/MS applied to benzodiazepines and their metabolites in clinical and forensic analysis ASMS 2011 WP171 Toshikazu Minohata1 , Natsuyo Asano1 , Kiyomi Arakawa1 , Jun Watanabe1 , Junko Iida1 , Hitoshi Tsuchihashi2 ,…
Key words
benzodiazepines, benzodiazepinesoxazepam, oxazepamdesmethyldiazepam, desmethyldiazepamtriggered, triggereddesalkylflurazepam, desalkylflurazepamforensic, forensicpolarity, polaritybenzodiazepine, benzodiazepinemrm, mrmswitching, switchingzolpidem, zolpidemdelorazepam, delorazepammetabolites, metabolitesfast, fastapplied