Organizer
Evosep Biosystems
Evosep Biosystems
Evosep develops new solutions to make clinical proteomics 100 times more robust and 10 times faster. We are basing our design on years of experience with nano-UHPLC R&D and application support, critically rethinking the necessary system architectures for successful sample separation before mass spectrometric analysis.
Tags
LC/MS
LC/MS/MS
LC/Orbitrap
LC/TOF
Ion Mobility
LC/HRMS
LinkedIn Logo

Unleashing the power of DIA combined with short gradients using the Evosep One

RECORD | Already taken place Th, 27.5.2021
In this webinar will discuss the practical application of DIA, generating record number is ID’s per minute, using the speed of Evosep One’s fast chromatography methods.
Go to the webinar
Evosep: Unleashing the power of DIA combined with short gradients using the Evosep One
Evosep: Unleashing the power of DIA combined with short gradients using the Evosep One

In the ever lasting effort to boost the number of protein identified in MS-based proteomic experiments, it has become clear that Data Independent Analysis (DIA), combined with short gradients, has become a winning combination.

PROGRAM

A PRACTICAL GUIDE TO HIGH-THROUGHPUT DATA-INDEPENDENT ACQUISITION

Data-independent acquisition (DIA) is an increasingly attractive strategy for high-throughput mass spectrometry-based proteomics. This presentation will give an introduction to state-of-the-art acquisition methods such as very fast Orbitrap mass analysis and diaPASEF.

We highlight key method parameters and illustrate their optimization for short gradients. Finally, we will discuss the integration of ion mobility spectrometry to improve ion sampling efficiency, increase sensitivity and reduce spectral complexity, leading to accurate label-free quantification of 6,000 proteins at a throughput of 60 samples per day.

Presenter: FLORIAN MEIER (JUNIOR PROFESSOR AT FRIEDRICH SCHILLER UNIVERSITY JENA)

BEYOND 5000 PROTEINS IN 4.8 MINUTES FROM LOW SAMPLE AMOUNTS

There is an increasing need for fast methods in proteomics. We have previously introduced DIA-NN, a neural network-based software suite capable of processing complex DIA proteomic data acquired with gradients as fast as 60-seconds. We now show that DIA-NN quantifies over 5000 proteins from just 200ng of a HeLa sample analysed with the 200 samples/day method on an Evosep One coupled to a timsTOF Pro.

This workflow enables high-throughput proteomics with data quality and sample amount requirements comparable to long-gradient nanoLC methods.

Presenter: VADIM DEMICHEV (PROJECT RESEARCH SCIENTIST AT THE FRANCIS CRICK INSTITUTE AND THE UNIVERSITY OF CAMBRIDGE)

Evosep Biosystems
LinkedIn Logo
 

Related content

Comprehensive and Robust Analysis of Ultrashort- to Long-Chain PFAS, PAE, OPE, and PAH

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Agilent Technologies, Plasmion
Industries
Environmental

UPLC™ Separation of Fifteen Bisphenols Using a Waters Acquity™ Biphenyl RP Column with MaxPeak™ Premier Technology and UV Detection

Applications
| 2026 | Waters
Instrumentation
Consumables, LC columns, HPLC
Manufacturer
Waters
Industries
Pharma & Biopharma

Achieving Low‑ppb Bisphenol Quantitation with the Agilent InfinityLab Pro iQ Mass Detector

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/SQ
Manufacturer
Agilent Technologies
Industries
Materials Testing

ECL detection of fentanyl

Applications
| 2026 | Metrohm
Instrumentation
Electrochemistry
Manufacturer
Metrohm
Industries
Forensics

Early-stage drug metabolite quantitation without radiolabels

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
HPLC, LC/MS, LC/SQ
Manufacturer
Thermo Fisher Scientific
Industries
Pharma & Biopharma, Metabolomics
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike