Organizer
Thermo Fisher Scientific
Thermo Fisher Scientific
A unique company dedicated to serving science helping our customers drive productivity and accelerate results. Through our premier brands – Thermo Scientific, Applied Biosystems, Invitrogen, Fisher Scientific and Unity Lab Services.
Tags
LC/MS
LC/MS/MS
LC/Orbitrap
LC/HRMS
LinkedIn Logo

Advancement of Analytical Technology for Oligonucleotide Analysis Using High-Resolution Accurate-Mass Mass Spectrometry

RECORD | Already taken place Tu, 22.6.2021
In this webinar, we will present the latest development of high-resolution accurate-mass (HRAM) based LC-MS methods for oligonucleotide and RNA analysis.
Go to the webinar
Thermo Fisher Scientific: Advancement of Analytical Technology for Oligonucleotide Analysis Using High-Resolution Accurate-Mass Mass Spectrometry
Thermo Fisher Scientific: Advancement of Analytical Technology for Oligonucleotide Analysis Using High-Resolution Accurate-Mass Mass Spectrometry

The advancement of oligonucleotide therapeutics and mRNA vaccine drives the need to develop robust analytical approaches for confident identification and in-depth characterization of these novel modalities.

We will demonstrate the capability of Thermo Scientific™ Vanquish Horizon™ UHPLC system and DNAPac™ RP column for robust and reproducible separation of oligonucleotides under the denaturing and non-denaturing conditions.

We will highlight the power of Thermo Scientific™ Orbitrap Exploris™ mass spectrometers for accurate mass measurement of oligonucleotides as large as 100mer.

Additionally, we will describe a data dependent MS/MS (ddMS2) method for high confidence identification, mapping, and relative quantitation of oligonucleotides and their impurities within a single experiment.

The characterization of degradation products and unexpected high molecular weight impurities of a synthetic oligonucleotide will also be examined. Data analysis using Thermo Scientific™ BioPharma Finder™ Software will also be explored, highlighting newly designed and novel tools to support the analysis and visualization of MSMS data for both modified and unmodified oligonucleotide workflows.

Key learning objectives:

  • Discover new LC-MS methods for oligonucleotide and RNA analysis.
  • Understand how a data dependent MS/MS (ddMS2) method can be applied to oligonucleotide identification, mapping, relative quantitation and impurity analysis.
  • Find out how BioPharma Finder™ Software can support your oligonucleotide analysis.

Who should attend;

  • Biopharmaceutical Research Scientists
  • Analytical Scientists from Biopharma companies working on or interested in oligonucleotide based therapies
  • PhD students in any field of biotherapeutic drug development
  • Scientists looking to advance knowledge of oligonucleotide analysis

Presenter: Dr. Kevin Guo (Senior Application Scientist, Thermo Fisher Scientific)

Dr. Kevin Kun Guo is a Senior Applications Scientist at Thermo Fisher Scientific with 18 years of experience running LC-MS systems, specializing in pharmaceutical and biopharmaceutical applications support. Before joining Thermo Fisher he was a Mass Spectrometry Scientist at Immunogen and completed his Ph.D. at the University of Alberta.

Presenter: Keeley Murphy (Software Product Manager, Thermo Fisher Scientific)

Keeley Murphy joined Thermo Fisher Scientific in 2008 and is currently working in the role of Software Product Manager, with a focus on the development of software workflows to support the LCMS analysis of oligonucleotides and mRNA. With 12 years of experience within Thermo Fisher Scientific, Keeley has contributed to numerous product launches and introductions for both hardware and software technologies designed to support biopharmaceutical development.

Thermo Fisher Scientific
LinkedIn Logo
 

Related content

Comprehensive and Robust Analysis of Ultrashort- to Long-Chain PFAS, PAE, OPE, and PAH

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Agilent Technologies, Plasmion
Industries
Environmental

UPLC™ Separation of Fifteen Bisphenols Using a Waters Acquity™ Biphenyl RP Column with MaxPeak™ Premier Technology and UV Detection

Applications
| 2026 | Waters
Instrumentation
Consumables, LC columns, HPLC
Manufacturer
Waters
Industries
Pharma & Biopharma

Achieving Low‑ppb Bisphenol Quantitation with the Agilent InfinityLab Pro iQ Mass Detector

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/SQ
Manufacturer
Agilent Technologies
Industries
Materials Testing

ECL detection of fentanyl

Applications
| 2026 | Metrohm
Instrumentation
Electrochemistry
Manufacturer
Metrohm
Industries
Forensics

Early-stage drug metabolite quantitation without radiolabels

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
HPLC, LC/MS, LC/SQ
Manufacturer
Thermo Fisher Scientific
Industries
Pharma & Biopharma, Metabolomics
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike