Organizer
C&EN
C&EN
Chemical & Engineering News (C&EN) is the flagship magazine of the American Chemical Society, an organization with over 157,000 members in over 100 countries. "Like" C&EN if you're a professional looking for chemistry news or are simply a chemistry fan.
Tags
GC
GC/MS
LC/MS
LC/MS/MS
HPLC
LC/QQQ
LinkedIn Logo

A Multidetector Approach to Reduce Uncertainty in Extractable and Leachable Analysis and Drug Impurity Characterization

RECORD | Already taken place Th, 12.8.2021
In this webinar, a multidetector approach for quantitation using the combined strengths of LC/QQQ and UV and CAD as well as GC/MS with simultaneous FID will be presented.
Go to the webinar
Agilent Technologies: A Multidetector Approach to Reduce Uncertainty in Extractable and Leachable Analysis and Drug Impurity Characterization
Agilent Technologies: A Multidetector Approach to Reduce Uncertainty in Extractable and Leachable Analysis and Drug Impurity Characterization

An important aspect of ensuring drug product quality is characterization of extractables and leachables (E&Ls) from pharmaceutical packaging following the guidance in USP <1663> and <1664>. Similarly, chemical characterization per ISO 10993 has become an integral component of biocompatibility testing of medical devices.

A major concern regarding the accuracy of extractables and leachables studies is quantitative error due to response factor (RF) variation. Surrogate standards are frequently applied in E&L analysis as many extractables do not have commercially available standards, and equal concentrations of different extractables give different signal responses using mass spectrometry detectors. Recent publications have highlighted the risks posed by RF variation for both LC/MS (Jordi et al. Journal of Pharmaceutical and Biomedical Analysis 150 (2018) 368–376) and GC/MS (Jenke and Odufu, Journal of Chromatographic Science 2012;50:206–212).

The significance of RF variation has been reflected in the addition of an uncertainty factor (UF) in the calculation of the analytical evaluation threshold (AET). While this approach aids in mitigating the risks of underreporting extractables, the resulting revised AET creates significant analytical challenges often exceeding the limit of detection (LOD) of current instrumentation requiring sample concentration. It is also one of the key issues at the root of poor reproducibility in recent high profile interlaboratory studies. It is therefore strongly desirable to develop methods for quantitation with more consistent RFs which mitigate the need for large UFs.

In this webinar, a multidetector approach for quantitation using the combined strengths of triple detection liquid chromatography mass spectrometry (LC/MS) with ultraviolet (UV) and charged aerosol detection (CAD) as well as Gas Chromatography Mass Spectrometry (GC/MS) with simultaneous Flame Ionization Detection (FID) will be presented. Data comparing the response factors for over 200 extractables by UV, MS, FID and CAD will be summarized showing which detectors provide reduced RF variation. An approach will be presented to reduce RF variation and the need for UFs through optimized detector and standard selection. Finally, the potential benefits of the multidetector approach for drug impurity characterization will be discussed as it relates to screening for low level mutagenic impurities.

Presenter: Dr. Mark Jordi (President, Jordi Labs)

Presenter: Ann Thayer (Contributing Editor, C&EN Media Group)

C&EN
LinkedIn Logo
 

Related content

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental

High Resolution Characterization of Lipid Nanoparticles Using the Xevo™ Charge Detection Mass Spectrometry (CDMS) Instrument - Single Particle Mass Analysis of Intact LNP-mRNA Formulations

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/HRMS, Particle characterization, LC/IT
Manufacturer
Waters
Industries
Lipidomics

Out-of-the-box workflow for PFAS quantitation using a fullscan high-resolution approach with the Orbitrap Exploris EFOX Mass Detector

Applications
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike