Organizer
Plasmion
Plasmion
We provide a novel sensor technology based on ambient mass spectrometry which does not only improve the utilization in traditional laboratory environments, but also enables the transfer of this kind of sensor technology to industrial process control, forensics, security technology (drugs, explosives, etc.) and the medical "point of care"​ diagnostics.
Tags
GC/MS
LC/MS
LinkedIn Logo

GC Coupling to LC-MS Instruments - Expand your Mass Spectrometric “View” with SICRIT

RECORD | Already taken place Tu, 5.5.2020
SICRIT® Ion source is a unique bridge between the GC and the LC world and provides 5 major advantages. Expand your mass spectrometric “view” with SICRIT®.
Go to the webinar
Plasmion: GC Coupling to LC-MS Instruments - Expand your Mass Spectrometric “View” with SICRIT
Plasmion: GC Coupling to LC-MS Instruments - Expand your Mass Spectrometric “View” with SICRIT

SICRIT® GC-Coupling Advantages

  1. Combination of LC-MS detection and GC separation enables more rigor and fast identification of analytes

  2. Ionization mechanism allows to cover a broader range of analytes – previously different systems required

  3. Soft ionization delivers molecular ion peaks and avoids complex and challenging allocation due to fragmentation

  4. Soft ionization allows to apply advanced detection models like SWATH or Data Dependent Acquisition (DDA)

  5. Combination with HRMS enables addition reliability in terms of substance identification

Conventional Ionization Technologies

With conventional atmospheric pressure methods, the ions are mostly formed outside the inlet of an MS. This implies that the substance to be analyzed (e.g. coffee) cannot be analyzed directly, but is usually "sprayed" into the MS in the form of a sample (liquid extract) via the ionization source.

SICRIT® Technology

The SICRIT® (Soft Ionization by Chemical Reaction In Transfer) ionization source is interfaced with the atmospheric pressure inlet of the MS and ionizes every substance which is drawn into the MS by its inherent vacuum.

Plasmion: Conventional MS Ionization Technologies vs. SICRIT® TechnologyPlasmion: Conventional MS Ionization Technologies vs. SICRIT® Technology

SICRIT® Characteristics

  • Simple extension of MS inlet
  • Concentric dielectric barrier discharge
  • Sample ionized during transfer into MS
  • Soft ionization by proton transfer and UV light
  • No consumables
Plasmion
LinkedIn Logo
 

Related content

Oligonucleotide Analysis Using the Agilent InfinityLab Pro iQ and Altura Oligo HPH-C18 Column

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/SQ, Consumables, LC columns
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental

High Resolution Characterization of Lipid Nanoparticles Using the Xevo™ Charge Detection Mass Spectrometry (CDMS) Instrument - Single Particle Mass Analysis of Intact LNP-mRNA Formulations

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/HRMS, Particle characterization, LC/IT
Manufacturer
Waters
Industries
Lipidomics
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike