LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Organizer
Bruker
Bruker
Bruker offers the world’s most comprehensive range of scientific instrumentation available under one brand - a brand synonymous with excellence, innovation and quality.
Tags
LC/MS
LC/MS/MS
LC/TOF
Ion Mobility
LC/HRMS
MALDI
LinkedIn Logo

RAFA 2021: Use timsTOF Ion Mobility technology to improve results in Food analysis

RECORD | Already taken place Th, 4.11.2021
We will discuss Using VIP-HESI and Trapped Ion Mobility Spectrometry to improve confidence in identification and workflow for setting up and controlling food authenticity analysis.
Go to the webinar
Bruker/RAFA 2021: Use timsTOF Ion Mobility technology to improve results in Food analysis
Bruker/RAFA 2021: Use timsTOF Ion Mobility technology to improve results in Food analysis

Using VIP-HESI and Trapped Ion Mobility Spectrometry to improve confidence in identification

In the past years, ion mobility has matured into an extremely valuable addition to high-resolution mass spectrometry. Trapped Ion Mobility (TIMS) technology ensures high resolution and highly accurate collisional cross section (CCS) values. Thus, this 4th dimension is able to filter out the chemical background and separate isobaric co-eluting compounds. The associated CCS values for all detected compounds can be used as an additional criteria for the identification of both knowns and unknowns. As ion mobility becomes more and more common, the number of CCS references values in libraries and databases is growing rapidly. When used in a targeted approach, as an additional criteria, CCS values help to increase the reliability of identification and reduce the number of false positives, especially speeding up the review of large sample sets. If TIMS is used in combination with the increased sensitivity obtained from a VIP-HESI source then positive identifications is possible at very low level concentrations. With a duty cycle of 100%, no changes to chromatographic gradients are required allowing this unique combination to provide analytical reporting with greater confidence.

Presenter: Dr. Carsten Baessmann (Bruker Daltonics GmbH & Co. KG, Bremen, Germany)

Workflow for setting up and controlling food authenticity analysis

Food adulteration and authenticity has a greater interest with the public in general and developments in hardware provides better sensitivity, and more accuracy, in elucidating these topics. Historically, the complexity of the workflow made these analyses a task for specialists. However, due to developments in software workflows, ‘ready-to-go’ solutions have been developed to determine authenticity markers and subsequently use them in a routine process. By having additional separation power provided by Trapped Ion Mobility Spectrometry (TIMS) and better calculation algorithms, minor differences in the food ‘fingerprint’ between different regions of authenticity, or lower levels of adulteration become easier to rapidly discern allowing large numbers of samples to be screened. Positioning of high through put MALDI and high separation HRMS will be explained within this presentation.

Presenter: Noud van der Borg, Bruker Nederland BV, Leiderdorp, Netherlands)

Bruker
LinkedIn Logo
 

Related content

Overcoming Strong Solvent Effects in the Analysis of Vepdegestrant

Applications
| 2026 | Agilent Technologies
Instrumentation
HPLC
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Identification of Double Bond Positions and Relative Acyl Chain Positions in Egg Yolk Phosphatidylcholines Using OAD-TOF System

Applications
| 2026 | Shimadzu
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Shimadzu
Industries
Food & Agriculture

High Molecular-Weight Polysaccharide Characterization by SEC-MALS Using GTxResolve™ 1000 and 2000 Å SEC Columns

Applications
| 2026 | Waters
Instrumentation
GPC/SEC, Consumables, LC columns
Manufacturer
Waters
Industries
Pharma & Biopharma, Food & Agriculture

Development and Optimization for a Comprehensive LC/MS/MS Method for the Detection of 74 PFAS Compounds

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Food & Agriculture

PFAS in Biota: Risk Context & Robust Analytical Solutions

Others
| 2026 | ALS Europe
Instrumentation
Laboratory analysis, LC/MS, LC/MS/MS
Manufacturer
Industries
Environmental
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike