Shimadzu Corporation has remained committed to commercializing cutting-edge technology and providing it to customers in a wide array of industries for more than 140 years. Our brand statement, "Excellence in Science"​, reflects our desire and attitude to diligently respond to customers'​ requirements by offering superior, world-class analytical and measuring instruments, medical imaging systems, aircraft equipment and industrial machinery for the advancement of human health, the safety and security of society, and industrial processes.
Tags
LC/MS
LC/MS/MS
LC/TOF
LC/HRMS
LinkedIn Logo

Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.

RECORD | Already taken place Tu, 27.11.2018
Various metrics that are relevant to statistical interpretation of MMA, which explain why mass resolution of 30,000 is more than sufficient for mass measurement.
Go to the webinar
Shimadzu: Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.
Shimadzu: Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.

High-resolution, accurate-mass (HRAM) mass spectrometers (MS) are a class of MS instrumentation with capability to resolve complex sample matrix and to allow identification of compounds by measuring their accurate masses.

In particular, those coupled to liquid chromatograph (HRAM LC/MS) have been used extensively for structural elucidation of unknown compounds primarily in chemical industry (impurity analysis) and biological researches (proteomics, metabolomics, lipidomics), but also increasingly in forensic science, food safety and environmental testing. Given the recent reduction of instrumentational cost, it will not take many more years until HRAM analysis becomes a versatile tool for all industries and researches.

The key performance attribute underlying all application fields is mass measurement accuracy (MMA) as it affords molecular specificity and reduction of false positive results. MMA is given in the specification of HRAM instruments in parts-per-million (ppm), frequently stating a result of a set of representative measurements e.g. “<1 ppm RMS”. However, this by itself does not convey how repeatably and reproducibly this MMA can be achieved.

The webinar describes various metrics that are relevant to statistical interpretation of MMA, which explain why mass resolution of 30,000 is more than sufficient for mass measurement at sub-ppm accuracy. Using the Shimadzu LCMS-9030 quadrupole time-of-flight MS, the rationale and strength of instrument stability for consistently achieving sub-ppm MMA has been demonstrated in small molecules.

Learning objectives:

Discuss how various parameters affect the accuracy of mass measurement
Demonstration of mass drift caused by temperature change
Learn how to assess whether a HRAM MS is practically capable of measuring at sub-ppm mass accuracy

Presenter: Atsuhiko (Ash) Toyama, PhD (MS Application Specialist, Analytical & Measuring Instruments Division, Shimadzu Corporation)

Ash Toyama has 10 years of proteomics research experience. His areas of expertise include not only proteomics but also quantitative mass spectrometry with particular focus on bioanalysis, metabolomics and endocrinology. At Shimadzu Corporation he played roles in academic research collaborations, application development and specification development of mass spectrometers. Ash holds a Master of Science degree in Biochemistry from University of Cambridge, UK, and was granted a Ph.D. degree in Biological Sciences from University of Tokyo for his research on clinical proteomics.

Shimadzu Corporation
LinkedIn Logo
 

Related content

Two-Step Matrix Deposition for Improved MS Imaging Resolution

Posters
| 2026 | Shimadzu (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, MALDI, MS Imaging
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Smart Monitoring & Optimization Solutions for SMB Processes: In-Line and Off-Line Tools for SMB Systems

Technical notes
| 2026 | KNAUER
Instrumentation
HPLC
Manufacturer
KNAUER
Industries
Pharma & Biopharma

Xevo MRT P10 Mass Spectrometer

Brochures and specifications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Metabolomics, Proteomics , Lipidomics

Large-Volume Dilute-and-Shoot Analysis of PFAS in Drinking Water Using the Altura PFAS Column

Applications
| 2026 | Agilent Technologies
Instrumentation
Consumables, LC columns, LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Hey, ho, oliGO – Comparison of ion-pairing systems for oligonucleotide analysis with HPLC-UV

Applications
| 2026 | KNAUER
Instrumentation
Consumables, LC columns, HPLC
Manufacturer
KNAUER
Industries
Pharma & Biopharma
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike