Shimadzu Corporation has remained committed to commercializing cutting-edge technology and providing it to customers in a wide array of industries for more than 140 years. Our brand statement, "Excellence in Science"​, reflects our desire and attitude to diligently respond to customers'​ requirements by offering superior, world-class analytical and measuring instruments, medical imaging systems, aircraft equipment and industrial machinery for the advancement of human health, the safety and security of society, and industrial processes.
Tags
LC/MS
LC/MS/MS
LC/TOF
LC/HRMS
LinkedIn Logo

Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.

RECORD | Already taken place Tu, 27.11.2018
Various metrics that are relevant to statistical interpretation of MMA, which explain why mass resolution of 30,000 is more than sufficient for mass measurement.
Go to the webinar
Shimadzu: Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.
Shimadzu: Understand the rationale behind the Q-TOF LC/MS that stably sustains sub-ppm mass accuracy.

High-resolution, accurate-mass (HRAM) mass spectrometers (MS) are a class of MS instrumentation with capability to resolve complex sample matrix and to allow identification of compounds by measuring their accurate masses.

In particular, those coupled to liquid chromatograph (HRAM LC/MS) have been used extensively for structural elucidation of unknown compounds primarily in chemical industry (impurity analysis) and biological researches (proteomics, metabolomics, lipidomics), but also increasingly in forensic science, food safety and environmental testing. Given the recent reduction of instrumentational cost, it will not take many more years until HRAM analysis becomes a versatile tool for all industries and researches.

The key performance attribute underlying all application fields is mass measurement accuracy (MMA) as it affords molecular specificity and reduction of false positive results. MMA is given in the specification of HRAM instruments in parts-per-million (ppm), frequently stating a result of a set of representative measurements e.g. “<1 ppm RMS”. However, this by itself does not convey how repeatably and reproducibly this MMA can be achieved.

The webinar describes various metrics that are relevant to statistical interpretation of MMA, which explain why mass resolution of 30,000 is more than sufficient for mass measurement at sub-ppm accuracy. Using the Shimadzu LCMS-9030 quadrupole time-of-flight MS, the rationale and strength of instrument stability for consistently achieving sub-ppm MMA has been demonstrated in small molecules.

Learning objectives:

Discuss how various parameters affect the accuracy of mass measurement
Demonstration of mass drift caused by temperature change
Learn how to assess whether a HRAM MS is practically capable of measuring at sub-ppm mass accuracy

Presenter: Atsuhiko (Ash) Toyama, PhD (MS Application Specialist, Analytical & Measuring Instruments Division, Shimadzu Corporation)

Ash Toyama has 10 years of proteomics research experience. His areas of expertise include not only proteomics but also quantitative mass spectrometry with particular focus on bioanalysis, metabolomics and endocrinology. At Shimadzu Corporation he played roles in academic research collaborations, application development and specification development of mass spectrometers. Ash holds a Master of Science degree in Biochemistry from University of Cambridge, UK, and was granted a Ph.D. degree in Biological Sciences from University of Tokyo for his research on clinical proteomics.

Shimadzu Corporation
LinkedIn Logo
 

Related content

Oligonucleotide Analysis Using the Agilent InfinityLab Pro iQ and Altura Oligo HPH-C18 Column

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/SQ, Consumables, LC columns
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental

High Resolution Characterization of Lipid Nanoparticles Using the Xevo™ Charge Detection Mass Spectrometry (CDMS) Instrument - Single Particle Mass Analysis of Intact LNP-mRNA Formulations

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/HRMS, Particle characterization, LC/IT
Manufacturer
Waters
Industries
Lipidomics
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike