Organizer
The Analytical Scientist
The Analytical Scientist
The Analytical Scientist focuses on the people, technology and innovations shaping measurement science. We cover analytical science by telling stories – delving into the hopes, fears, motivations and aspirations of the key figures in the field.
Tags
OMICS
LC/Orbitrap
LinkedIn Logo

Advancing molecular glue discovery through high throughput mass spectrometry based proteomics on Orbitrap Astral mass spectrometer

RECORD | Already taken place Th, 27.6.2024
Learn about the novel Orbitrap Astral Mass Spectrometer and it's capabilities to perform Targeted Protein Degradation (TPD) studies.
Go to the webinar
The Analytical Scientist: Advancing molecular glue discovery through high throughput mass spectrometry based proteomics on Orbitrap Astral mass spectrometer.
The Analytical Scientist: Advancing molecular glue discovery through high throughput mass spectrometry based proteomics on Orbitrap Astral mass spectrometer.

The field of Targeted Protein Degradation (TPD) has emerged as a new therapeutic modality to harness the ubiquitin-proteasome system for targeting proteins that were once considered undruggable through the traditional inhibitor-based modalities.

TPD primarily relies on heterobifunctional molecules like proteolysis-targeting chimeras (PROTACs) and molecular glues to bring the target proteins into proximity to the ubiquitin-proteasome system to induce protein degradation.

Molecular glues are monovalent small molecules with drug-like properties that alter the protein binding surface of E3 ligase, resulting in novel E3 ligase and target protein interactions. Molecular glues are difficult to design and are often discovered retrospectively.

The rational design and discovery of molecular glues require an untargeted approach to understand the protein ternary complexes, target protein degradation, and ubiquitination induced by potential molecular glues.

We have leveraged untargeted, high-throughput proteomic approaches to better understand protein-protein interactions and target protein degradation induced by prospective molecular glues.

The recent developments in the field of high-throughput proteomics due to the introduction of faster and more sensitive mass spectrometers have brought us closer to the rational design and discovery of molecular glues.

Webinar learning objectives:

  • The use of mass spectrometry to perform Targeted Protein Degradation (TPD) studies.
  • Use of high-throughput proteomic approaches to better understand protein-protein interactions and target protein degradation induced by prospective molecular glues.
  • Learn about the novel Orbitrap Astral Mass Spectrometer and it's capabilities.

Presenter: Aman Makaju (Senior Scientist, Amgen, Aman Makaju is a senior scientist in the Discovery Proteomics Group at Amgen Research and Development)

In his current capacity, he plays a crucial role in supporting Amgen’s Drug Discovery pipeline through the application of mass spectrometry-based proteomics. Aman is an integral part of a dynamic team that has successfully developed a cutting-edge, high-throughput mass spectrometry-based proteomics platform.

This platform has been designed to expedite the discovery process of induced protein proximity modalities, with a particular emphasis on identifying and characterizing molecular glues for targeted protein degradation. The platform's capabilities include the untargeted identification of glue-induced protein-protein interactions, tracking on- and off-target protein degradation events, and monitoring the ubiquitination of target proteins.

The Analytical Scientist
LinkedIn Logo
 

Related content

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental

High Resolution Characterization of Lipid Nanoparticles Using the Xevo™ Charge Detection Mass Spectrometry (CDMS) Instrument - Single Particle Mass Analysis of Intact LNP-mRNA Formulations

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/HRMS, Particle characterization, LC/IT
Manufacturer
Waters
Industries
Lipidomics

Out-of-the-box workflow for PFAS quantitation using a fullscan high-resolution approach with the Orbitrap Exploris EFOX Mass Detector

Applications
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Environmental
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike