Organizer
Agilent Technologies
Agilent Technologies
Analytical scientists and clinical researchers worldwide rely on Agilent to help fulfill their most complex laboratory demands. Our instruments, software, services and consumables address the full range of scientific and laboratory management needs.
Tags
LC/MS
LC/MS/MS
LC/QQQ
LinkedIn Logo

Rapid and Sensitive Determination of Haloacetic Acids and Acrylamide in Drinking Water using LC-Triple Quadrupole Mass Spectrometry

RECORD | Already taken place We, 12.2.2025
How the Agilent LC-Triple Quadrupole mass spectrometers are able to quantify compounds to meet the Directive (EU) 2020/2184 regulation.
Go to the webinar
Agilent Technologies: Watertight Analytical Workflows to Meet EU Directive 2020-2184
Agilent Technologies: Watertight Analytical Workflows to Meet EU Directive 2020-2184

Haloacetic Acids (HAAs) and acrylamide are introduced into the drinking  water supply during different stages of the water treatment process. HAAs are formed as unwanted disinfection by-products (DBPs) when chlorine is added to waters sources to kill pathogens whilst acrylamide is indirectly introduced via the use of polyacrylamide as a  flocculant during water treatment.

Both compound classes are carcinogenic, whilst acrylamide is also known to also be mutagenic, and reprotoxic, thus requiring their levels in drinking  water to be strictly  measured.

Here we describe how the Agilent LC-Triple Quadrupole mass spectrometers are able to quantify these compounds to meet the Directive (EU) 2020/2184 regulation.

Presenter: Henry Russell (LC/MS Product Specialist, Agilent Technologies)

Henry Russell is a LC/MS Product Specialist, supporting our business partners in many countries in the EMEA region. Henry has worked in various roles with Agilent since 2001.

Previous to Agilent, Henry worked with a UK based channel partner following being employed in laboratory positions with commercial contract laboratories for several years.

Agilent Technologies
LinkedIn Logo
 

Related content

Suppressed Cation Analysis of Wastewater Using Ion Chromatograph Nexera IC, Conforming to ASTM D6919-17

Applications
| 2026 | Shimadzu
Instrumentation
Ion chromatography
Manufacturer
Shimadzu
Industries
Environmental, Food & Agriculture

Comprehensive and Robust Analysis of Ultrashort- to Long-Chain PFAS, PAE, OPE, and PAH

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Agilent Technologies, Plasmion
Industries
Environmental

UPLC™ Separation of Fifteen Bisphenols Using a Waters Acquity™ Biphenyl RP Column with MaxPeak™ Premier Technology and UV Detection

Applications
| 2026 | Waters
Instrumentation
Consumables, LC columns, HPLC
Manufacturer
Waters
Industries
Pharma & Biopharma

Achieving Low‑ppb Bisphenol Quantitation with the Agilent InfinityLab Pro iQ Mass Detector

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/SQ
Manufacturer
Agilent Technologies
Industries
Materials Testing

ECL detection of fentanyl

Applications
| 2026 | Metrohm
Instrumentation
Electrochemistry
Manufacturer
Metrohm
Industries
Forensics
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike