Organizer
C&EN
C&EN
Chemical & Engineering News (C&EN) is the flagship magazine of the American Chemical Society, an organization with over 157,000 members in over 100 countries. "Like" C&EN if you're a professional looking for chemistry news or are simply a chemistry fan.
Tags
LC/MS
LC/MS/MS
Sample prep
SPE
LinkedIn Logo

Eliminating Matrix Effects in Lipid-rich, Full-Fish Homogenates

RECORD | Already taken place Tu, 25.2.2025
Join this webinar to understand the limitations of the basic pH method in EPA 1633 when analyzing lipid-rich, full-fish homogenates.
Go to the webinar
Phenomenex: Eliminating Matrix Effects in Lipid-rich, Full-Fish Homogenates
Phenomenex: Eliminating Matrix Effects in Lipid-rich, Full-Fish Homogenates

Extracting PFAS from dirty matrices is a challenging task. With the finalization of the EPA Method 1633 (Analysis of Per- and Polyfluoroalkyl Substances in Aqueous, Solid, Biosolids, and Tissue Samples by LC-MS/MS), the scientific community is closer to reaching that goal. However, the basic pH method in EPA 1633 is not suitable for some of the most complicated matrices, including lipid-rich, full-fish homogenates. Basic methods are lipid-limited and there is an increased likelihood of incomplete separation of PFAS due to significant matrix interferences. This poses a challenge for analyzing PFAS in whole fish (as opposed to fillets or organs) which can provide valuable information about both human and animal exposure through consumption.

In addition, many methods focus on the analysis of PFAS in fish fillets with the primary purpose of informing human consumption advisories. However, this is likely not representative of the PFAS burden consumed by aquatic predators, who generally eat most of the fish, if not all. Some internal organs, such as the liver, have higher concentrations of PFAS than the fillet. Analyzing the homogenate of a whole fish provides a holistic view of animal exposure through consumption, as well as exposure for the fish itself.

We developed an extraction method that can be used to analyze linear perfluorocarboxylic & perfluorosulfonic acids in lipid-rich, full-fish homogenates. Recoveries of PFCAs & PFSAs were between 73 and 104%, which is comparable, if not improved from, the acceptable range in EPA 1633. This method allowed us to analyze homogenized Pacific Herring and Chinook salmon samples. EPA Method 1633 was tested on these samples, but there was no recovery of target analytes. Using the method in this presentation, linear PFCAs were detected 54% of the time with an average concentration and SEM of 5.2±1.9 ng/g ww. Linear PFSAs were detected in 73% of samples with an average concentration of 1.6±0.2 ng/g ww. As with most other biological samples, the profile of linear PFSAs was predominantly PFOS, which had a detection frequency of 73% and an average concentration of 1.4±0.2 ng/g ww..

While this method does have trade-offs with EPA Method 1633, including a smaller amenable suite of analytes, it can be used to determine trophic magnification of PFAS more accurately. Additionally, this method can be used on banked fish samples that have been homogenized before storage, providing an opportunity for historical sample analysis.

Key Objectives:

  • Understand the limitations of the basic pH method in EPA 1633 when analyzing lipid-rich, full-fish homogenates.
  • Explore a new extraction method that can be used to analyze linear perfluorocarboxylic and perfluorosulfonic acids for a more efficient and accurate analysis.

Presenter: Richard Jack, Ph.D., (Global Market Development Manager, Phenomenex)

Presenter: Sydney Brady (Ph.D. Candidate, Indiana University O´Neill School of Public and Environmental Affairs, Bloomington, IN)

C&EN
LinkedIn Logo
 

Related content

Benefits of Agilent Altura Ultra Inert HPLC Column Hardware

Applications
| 2026 | Agilent Technologies
Instrumentation
Consumables, LC columns
Manufacturer
Agilent Technologies
Industries
Environmental

Vinylene carbonate water determination via coulometric Karl Fischer titration

Applications
| 2026 | Metrohm
Instrumentation
Titration Karl Fischer, Voltammetry/Coulometry
Manufacturer
Metrohm
Industries
Semiconductor Analysis

An Isocratic Separation of B Vitamins Using Waters XBridge Biphenyl RP Column with MaxPeak Premier Technology

Applications
| 2026 | Waters
Instrumentation
Consumables, LC columns
Manufacturer
Waters
Industries
Pharma & Biopharma

Impurity Monitoring of GLP-1 Therapeutic Peptide RetatrutideUsing a 2D-LC/TOF System

Posters
| 2026 | Agilent Technologies (ASMS)
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS, 2D-LC
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Increased sensitivity for low-input label-free proteomics using the Orbitrap Astral MS and μPAC Neo Plus Columns

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/HRMS, LC/Orbitrap, LC/MS, LC/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Proteomics
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike