LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Organizer
Thermo Fisher Scientific
Thermo Fisher Scientific
A unique company dedicated to serving science helping our customers drive productivity and accelerate results. Through our premier brands – Thermo Scientific, Applied Biosystems, Invitrogen, Fisher Scientific and Unity Lab Services.
Tags
HPLC
LinkedIn Logo

Why HPLC-CAD is ideal for quality assurance of APIs and excipients

We, 25.3.2026 15:00 CET
Discover how HPLC-CAD enhances impurity profiling of APIs and excipients, enabling sensitive, near-universal detection beyond UV limits for robust pharmaceutical quality control workflows.
Go to the webinar
Thermo Fisher Scientific: Why HPLC-CAD is ideal for quality assurance of APIs and excipients
Thermo Fisher Scientific: Why HPLC-CAD is ideal for quality assurance of APIs and excipients

The gold standard of quality assessment of drugs is nowadays an HPLC using a reversed-phase (RP) column chromatography and aqueous buffers, acetonitrile, and/or methanol as mobile phase, combined with a UV detector.

As many excipients and active pharmaceutical ingredients (APIs) do not have a chromophore, these compounds are not suitable for identification and quantification by UV detection. In this situation, the near-universal Charged Aerosol Detector (CAD) is an excellent alternative capable of detecting almost all non-volatile compounds.

One critical thing to know is that the mobile phase composition—often dictated by solid phase chemistry—can influence the CAD response. In addition to RP techniques, chromatographers often apply ion pair chromatography (IPC), mixed mode (MMC), and hydrophilic interaction (HILIC) methods. We will discuss how these solid phases influence selectivity and sensitivity of the CAD when analyzing the purity of APIs such as amino acids, vigabatrin, ibandronate, atropine, and gabapentin, as well as excipients, e.g., fatty acids, PEGs, and polysorbates.

These examples will demonstrate the versatility of HPLC-CAD for quantifying low concentrations of impurities in APIs and excipients. Sensitivity is of great importance in the quality control of drugs.

Key Learning Objectives:

  • Quality assurance by HPLC-CAD, enhancement of sensitivity, impurity profiling of APIs and excipients.

Key learning and takeaways include:

  • Explore on the critical yet increasingly complex challenge of impurity profiling of APIs and excipients in pharmaceutical analysis
  • Review on enhancement of sensitivity in detection to uncover low-level impurities
  • Discover examples for quality assurance by HPLC-CAD analysis

Presenter: Ulrike Holzgrabe (Senior-Professor Pharmaceutical and Medicinal Chemistry, University of Würzburg)

Ulrike Holzgrabe holds a diploma in Chemistry and an approbation in Pharmacy. After habilitation in Kiel she became a professor of Pharmaceutical Chemistry at the University of Bonn and from 1999 till 2022 she holds a chair of Pharmaceutical and Medicinal Chemistry in Würzburg. She served for some 25 years as an expert of the German pharmacopoeia commission (at BfArM) and for 18 years as an expert and president of two expert groups at the European Directorate of the Quality of Medicines and HealthCare (EDQM). She has published 500+ papers in the field of quality assurance of drugs and medicinal chemistry.

Presenter: Frank Steiner (Senior Manager of Product Applications, Thermo Fisher Scientific)

Frank Steiner is the Senior Manager of Product Applications and helps coordinate scientific collaborations at Thermo Fisher Scientific. He received his Ph.D. in Analytical Chemistry from Saarland University in Saarbrücken, Germany, and has published 30+ publications in refereed journals and 10+ textbook chapters on HPLC topics.

Thermo Fisher Scientific
LinkedIn Logo
 

Related content

Analysis of Anti-Degradant Additive (6PPD) and its Transformation Product 6PPD-Quinone in Tire Rubber Using an Integrated HPLC System

Applications
| 2026 | Shimadzu
Instrumentation
HPLC
Manufacturer
Shimadzu
Industries
Energy & Chemicals

Performance Evaluation of Microbial Identification Using a Benchtop MALDI-TOF MS

Applications
| 2026 | Shimadzu
Instrumentation
MALDI, LC/MS, LC/TOF, Software
Manufacturer
Shimadzu
Industries
Pharma & Biopharma, Food & Agriculture

A Combined Method for Anionic, Cationic, and Zwitterionic PFAS using a Direct Injection UPLC™-MS/MS Method for Environmental Water Samples

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Waters
Industries
Environmental

Beyond the box: A ready-to-run workflow for quantitating 80 drugs of abuse in whole blood with the TSQ Certis Triple Quadrupole MS

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Thermo Fisher Scientific
Industries
Forensics

Mastering Single Cell Proteomics: Daily Excellence with μPAC Neo Plus Trap-and-Elute Workflow

Presentations
| 2026 | Thermo Fisher Scientific
Instrumentation
HPLC, LC/Orbitrap, LC/MS, LC/MS/MS
Manufacturer
Thermo Fisher Scientific
Industries
Proteomics
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike