Organizer
Agilent Technologies
Agilent Technologies
Analytical scientists and clinical researchers worldwide rely on Agilent to help fulfill their most complex laboratory demands. Our instruments, software, services and consumables address the full range of scientific and laboratory management needs.
Tags
LC/MS
LC/MS/MS
LC/TOF
Ion Mobility
LC/HRMS
MALDI
LinkedIn Logo

Characterization of MassTech AP MALDI Source with Agilent 6545 QTOF and 6560 IM-QTOF for MS Imaging

RECORD | Already taken place Tu, 30.3.2021
The AP MALDI source developed by MassTech Inc was hyphenated to Agilent 6545, a high-resolution mass spectrometer. AP MALDI MS imaging was demonstrated using tissue-simulating peptide spots.
Go to the webinar
Agilent Technologies: Characterization of MassTech AP MALDI Source with Agilent 6545 QTOF and 6560 IM-QTOF for MS Imaging
Agilent Technologies: Characterization of MassTech AP MALDI Source with Agilent 6545 QTOF and 6560 IM-QTOF for MS Imaging

Atmospheric pressure (AP) MALDI is broadly used in the high-throughput mass analysis of lipids, peptides, and small molecule as well as MS imaging (MSI) studies. AP-MALDI is an affordable and quickly mounted addition onto MS instruments operating with electrospray ionization sources. Its clear advantage is easy sample handling at the atmospheric conditions along with the use of semi-volatile matrices that can be important in MSI experiments taking hours of instrument operation.

The AP MALDI source developed by MassTech Inc was hyphenated to Agilent 6545, a high-resolution mass spectrometer. Samples were prepared from peptide standards mixed with alpha-CHCA, a MALDI matrix. Limits of detection for peptides were attained at single fmol or sub-fmol levels. Importantly, the isotopic peak intensities followed closely to their theoretical values. This spectral feature is typically not observed in ion trap or FT-ICR instruments.

AP MALDI MS imaging was demonstrated using tissue-simulating peptide spots. MS imaging experiment typically included an imaging area setup using new Target Next software, data collection using Agilent MS Hunter acquisition software, and data format conversion for using an industry standard imaging visualization software package. MS images with a 30-micron spatial resolution and high S/N ratios for analyte peaks have been demonstrated.

For Research Use Only. Not for use in diagnostic procedures.

Presenter: Vladimir M. Doroshenko, PhD (Chief Executive Officer, MassTech Inc.)

  • M.S. and Ph.D. in Chemical Physics from Moscow Institute of Physics and Technology (1982).
  • Post-doctoral training in Analytical Chemistry, The Johns Hopkins University, Baltimore, MD (1991-1993).
  • Research Scientist, The Johns Hopkins University, Baltimore, MD (1994-1997).
  • Chief Scientist, Science & Engineering Services Inc., Columbia, MD (1997 – 2014).
  • Chief Executive Officer, MassTech Inc., Columbia, MD, 2014 - present.
  • Over 100 publications in peer-reviewed journals, 25 patents.

Presenter: Eugene Moskovets, PhD (Principal Scientist, MassTech Inc.)

  • B.S. and M.S. in Physics/Biophysics from Moscow Institute of Physics and Technology.
  • Ph.D. in Laser Mass Spectrometry from Institute for Spectroscopy (Moscow, Russia) -1994
  • Post-doctoral training, George Washington University, Wash DC 1997-98
  • Senior Scientist, Barnett Institute at Northeastern University, Boston MA, 1999-2007
  • Principal Scientist, MassTech Inc. (Columbia MD) 2007- present.
  • Over 50 publications in peer-reviewed journals, over 70 conference presentations. 3 patents.

Presenter: Richard Lee (Head of Marketing and Business Development, MassTech Inc.)

I am 39 years old, worked for SES and now Masstech, Inc. I have been the head of marketing and business development for a little under 2 years. I graduated from William and Mary with a bachelor’s degree in Economics, and have worked extensively in the investment industry, as well as an accountant.

Agilent Technologies
LinkedIn Logo
 

Related content

Early-stage drug metabolite quantitation without radiolabels

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
HPLC, LC/MS, LC/SQ
Manufacturer
Thermo Fisher Scientific
Industries
Pharma & Biopharma, Metabolomics

Oligonucleotide Analysis Using the Agilent InfinityLab Pro iQ and Altura Oligo HPH-C18 Column

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/SQ, Consumables, LC columns
Manufacturer
Agilent Technologies
Industries
Pharma & Biopharma

Simultaneous Quantitation and Discovery analysis: Combining targeted and untargeted metabolomics on Orbitrap mass spectrometers

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Metabolomics

Analysis of Per- and Polyfluoroalkyl Substances (PFAS) in Wastewater

Applications
| 2026 | Agilent Technologies
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Agilent Technologies
Industries
Environmental

Non-Targeted Screening of Biosolids with the Xevo™ MRT Mass Spectrometer Reveals New Isoforms of PFAS

Applications
| 2026 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/TOF, LC/HRMS
Manufacturer
Waters
Industries
Environmental
Other projects
GCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike