LCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Author
RECETOX - Centrum pro výzkum toxických látek v prostředí
RECETOX - Centrum pro výzkum toxických látek v prostředí
RECETOX (Research Centre for Toxic Compounds in the Environment) is an independent department of the Faculty of Science of Masaryk University in Brno, which has been established in 1983. RECETOX is focused on the research and education in cross-cutting area of Environment and Health. It addresses interactions among chemicals, environment, and biological systems, including consequences at local, regional, and global levels.
Tags
Article
Science and research
Scientific article
LinkedIn Logo

Scientists have found that summer heat significantly increases the release of flame retardants in cars

Fr, 28.11.2025
| Original article from: RECETOX
RECETOX researchers showed that some flame retardants in car interiors rise up to 700× in summer compared to winter, revealing strong temperature-driven exposure risks for drivers and passengers.
<p>RECETOX: Scientists have found that summer heat significantly increases the release of flame retardants in cars</p>

RECETOX: Scientists have found that summer heat significantly increases the release of flame retardants in cars

In a newly published study in Environmental Science: Advances, researchers from RECETOX demonstrated that temperature and seasonal changes significantly influence the amount of flame retardants released from materials inside car interiors. The study is the first of its kind to simultaneously measure the concentrations of these substances in air, dust, and the interior materials themselves. The results show that some chemicals, such as phosphate flame retardant TCEP, reach concentrations up to 700 times higher in summer car air than in winter. 

RECETOX: Samples from the examined car, shown in the photo, included seat foam, soft plastic from the upper dashboard, and hard plastic from various parts of the vehicle (lower dashboard, center console, and doors). The samples were collected in a way that ensured sufficient material for extraction and analysis, while avoiding any functional or visible damage to the vehicle.RECETOX: Samples from the examined car, shown in the photo, included seat foam, soft plastic from the upper dashboard, and hard plastic from various parts of the vehicle (lower dashboard, center console, and doors). The samples were collected in a way that ensured sufficient material for extraction and analysis, while avoiding any functional or visible damage to the vehicle.

Flame retardants, which are used to reduce the flammability of plastics, foams, and textiles, are commonly found not only in furniture and electronics, such as in sofas, but also in car interiors. Unlike our homes, however, cars are exposed to extreme conditions: in summer, the temperature inside a parked car in the sun can be 20–50 °C higher than outside. These substances can be released from materials into the surrounding environment, accumulate in dust that we come into contact with, or remain in the air we breathe. Although the use of flame retardants is based on safety requirements to reduce flammability, growing evidence shows that some of these chemicals may harm human health and the environment.  

RECETOX: A polyurethane foam disk used for air sampling at the end of the car's heat exposure period and sunlight.RECETOX: A polyurethane foam disk used for air sampling at the end of the car's heat exposure period and sunlight.

“This study found clear seasonal differences in the chemical concentrations in air inside a car. In summer, the levels of some phosphate flame retardants were up to 700× higher than in winter. Temperature has a clear influence the behavior of these substances and their release rate from the car interior materials (seat fabrics, foams and plastics). The highest concentrations can be expected in summer, especially in the first moments of car use. An interesting finding, however, was that temperature did not have such a strong effect on dust concentrations, which remained high even during winter and therefore better reflect what we are exposed to in cars in the long term,” explains the lead author of the study Petra Svobodová.

RECETOX: Dust collected after the car was exposed to heat and sunlight (using a specialized forensic sampling head), with the sample taken from multiple locations inside the vehicle.RECETOX: Dust collected after the car was exposed to heat and sunlight (using a specialized forensic sampling head), with the sample taken from multiple locations inside the vehicle.

Simultaneous measurement of air, dust, and the interior materials themselves made it possible to better understand chemical sources. For example, TCIPP, another phosphate flame retardant which was also elevated in summer air, was measured at the highest concentrations in the dashboard material, where temperatures under direct sunlight can reach up to 80 °C.

RECETOX: A thermometer recording temperatures during the experiment, which were later compared with outdoor temperatures (this one during the winter experiment).RECETOX: A thermometer recording temperatures during the experiment, which were later compared with outdoor temperatures (this one during the winter experiment).

We recommend several measures to reduce exposure to these chemicals in cars: proper ventilation before driving, not only in summer months, regular cleaning of the interior (vacuuming, dust wiping), protecting car interior from high temperatures, keeping the air conditioning in good condition, and also washing hands after using the car.  

The original article

Investigation of seasonal changes in flame retardant concentrations in car interiors

Petra Svobodová, Simona Rozárka Jílková, Jiří Kohoutek, Ondřej Audy
and Lisa Melymuk

Environ. Sci.: Adv., 2025, 4, 2027

10.1039/d5va00228a

licensed under CC-BY 4.0

Selected sections from the article follow. Formats and hyperlinks were adapted from the original.

We investigated how temperature influences flame retardant levels in vehicle air and dust, and analyzed vehicle interior materials to identify major sources. Airborne concentrations of flame retardants varied dramatically, with some compounds increasing over 50 000-fold at elevated summer temperatures compared to winter temperatures. In contrast, dust levels were more stable but consistently high, reflecting substantial flame retardant content in interior materials. All sampled vehicle materials contained more than 1 mg g−1 of three chlorinated organophosphate flame retardants. The combination of high material concentrations and temperature-driven emissions suggests that individuals who spend an extended time in vehicles may face elevated exposure to these chemicals, particularly during warmer conditions.

2.3 Extraction and analysis

Complete information on dust sample extraction, clean-up and analysis has been published previously25 and is given in detail in the SI in Texts S1 and S2. Dust samples with filters were ground using a ball mill and weighed. Dust and car material samples (plastic and foam) were divided into two aliquots for separate extraction of OPEs and BDE 209. For OPE analysis, samples were extracted by ultrasonic extraction in methanol and analysed by LC-MS. For BDE-209 analysis, samples were extracted by ultrasonic extraction in 1 : 1 hexane:acetone and analyzed by GC-HRMS. PUFs were cut into two fractions and extracted by Soxhlet extraction, using methanol for OPE analysis, and dichloromethane for BDE 209 analysis. BDE 209 and 14 OPEs (TCEP, TCIPP, TDCIPP, TBOEP, TPhP, oTMPP, CDP, TDBPP, TnPP, ip-TPP, TEHP, TEP, TBP and EHDPP) were analysed. 

RECETOX - Centrum pro výzkum toxických látek v prostředí
LinkedIn Logo
 

Related content

Seized Drug Analysis Using ASAP-MS and Multivariate Analysis Models

Posters
| 2025 | Waters (TIAFT)
Instrumentation
LC/MS, LC/SQ, DART
Manufacturer
Waters
Industries
Forensics

Sensitive and selective quantitation of bile acids using targeted MS2/MS3 on the Stellar mass spectrometer

Posters
| 2025 | Thermo Fisher Scientific (MSACL)
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Clinical Research

Selective and sensitive measurement of 17 steroids in human serum using a Stellar mass spectrometer

Technical notes
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Clinical Research

Automated Multiple Reaction Monitoring (MRM) Method Development for Peptide Drugs Using waters_connect for Quantitation Software

Applications
| 2025 | Waters
Instrumentation
Software, LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Waters
Industries
Pharma & Biopharma

Constant Neutral Loss, Precursor Ion Scanning, Product Ion Scanning in Support of DMPK Studies Using waters_connect for Quantitation Software Solution and Xevo TQ Absolute XR Mass Spectrometer

Applications
| 2025 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ, Software
Manufacturer
Waters
Industries
Pharma & Biopharma, Clinical Research, Metabolomics
 

Related articles

How is Normal Phase (NP) SPE Different from Reversed-Phase (RP) SPE?
Article | Academy

How is Normal Phase (NP) SPE Different from Reversed-Phase (RP) SPE?

A clear guide to Normal Phase SPE: when to use it, how polar interactions drive retention, and which solvents to choose in increasing polarity—plus a quick reference list for optimized sample preparation.
Phenomenex
tag
share
more
Inertsil Hybrid-C18: Stability Across a Wide pH Range
Article | Product

Inertsil Hybrid-C18: Stability Across a Wide pH Range

Discover how Inertsil Hybrid-C18 brings exceptional stability, wide pH tolerance, and long-term reproducibility to modern LC/MS workflows—now available with a special promotion from Watrex Prague.
Watrex Praha
tag
share
more
Stick and Glue! Tomáš Slanina and his team introduce a new biomolecule-labeling method for more precise observation of cellular processes
Article | Science and research

Stick and Glue! Tomáš Slanina and his team introduce a new biomolecule-labeling method for more precise observation of cellular processes

Researchers at IOCB Prague developed a highly precise and ultra-stable fluorescent labeling method that stays attached even inside cells, enabling long-term, reliable tracking of biomolecules.
Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences
tag
share
more
Sample Preparation Mastery: Expert Insights on Evaporation Techniques for Chromatography
Interview | Video

Sample Preparation Mastery: Expert Insights on Evaporation Techniques for Chromatography

Discover how rotary, centrifugal and freeze-drying techniques compare in modern sample prep. In this expert interview, Wade explains trade-offs in cost, throughput, analyte integrity and automation.
Organomation
tag
share
more
 

Related content

Seized Drug Analysis Using ASAP-MS and Multivariate Analysis Models

Posters
| 2025 | Waters (TIAFT)
Instrumentation
LC/MS, LC/SQ, DART
Manufacturer
Waters
Industries
Forensics

Sensitive and selective quantitation of bile acids using targeted MS2/MS3 on the Stellar mass spectrometer

Posters
| 2025 | Thermo Fisher Scientific (MSACL)
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Clinical Research

Selective and sensitive measurement of 17 steroids in human serum using a Stellar mass spectrometer

Technical notes
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Clinical Research

Automated Multiple Reaction Monitoring (MRM) Method Development for Peptide Drugs Using waters_connect for Quantitation Software

Applications
| 2025 | Waters
Instrumentation
Software, LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Waters
Industries
Pharma & Biopharma

Constant Neutral Loss, Precursor Ion Scanning, Product Ion Scanning in Support of DMPK Studies Using waters_connect for Quantitation Software Solution and Xevo TQ Absolute XR Mass Spectrometer

Applications
| 2025 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ, Software
Manufacturer
Waters
Industries
Pharma & Biopharma, Clinical Research, Metabolomics
 

Related articles

How is Normal Phase (NP) SPE Different from Reversed-Phase (RP) SPE?
Article | Academy

How is Normal Phase (NP) SPE Different from Reversed-Phase (RP) SPE?

A clear guide to Normal Phase SPE: when to use it, how polar interactions drive retention, and which solvents to choose in increasing polarity—plus a quick reference list for optimized sample preparation.
Phenomenex
tag
share
more
Inertsil Hybrid-C18: Stability Across a Wide pH Range
Article | Product

Inertsil Hybrid-C18: Stability Across a Wide pH Range

Discover how Inertsil Hybrid-C18 brings exceptional stability, wide pH tolerance, and long-term reproducibility to modern LC/MS workflows—now available with a special promotion from Watrex Prague.
Watrex Praha
tag
share
more
Stick and Glue! Tomáš Slanina and his team introduce a new biomolecule-labeling method for more precise observation of cellular processes
Article | Science and research

Stick and Glue! Tomáš Slanina and his team introduce a new biomolecule-labeling method for more precise observation of cellular processes

Researchers at IOCB Prague developed a highly precise and ultra-stable fluorescent labeling method that stays attached even inside cells, enabling long-term, reliable tracking of biomolecules.
Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences
tag
share
more
Sample Preparation Mastery: Expert Insights on Evaporation Techniques for Chromatography
Interview | Video

Sample Preparation Mastery: Expert Insights on Evaporation Techniques for Chromatography

Discover how rotary, centrifugal and freeze-drying techniques compare in modern sample prep. In this expert interview, Wade explains trade-offs in cost, throughput, analyte integrity and automation.
Organomation
tag
share
more
 

Related content

Seized Drug Analysis Using ASAP-MS and Multivariate Analysis Models

Posters
| 2025 | Waters (TIAFT)
Instrumentation
LC/MS, LC/SQ, DART
Manufacturer
Waters
Industries
Forensics

Sensitive and selective quantitation of bile acids using targeted MS2/MS3 on the Stellar mass spectrometer

Posters
| 2025 | Thermo Fisher Scientific (MSACL)
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Clinical Research

Selective and sensitive measurement of 17 steroids in human serum using a Stellar mass spectrometer

Technical notes
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Clinical Research

Automated Multiple Reaction Monitoring (MRM) Method Development for Peptide Drugs Using waters_connect for Quantitation Software

Applications
| 2025 | Waters
Instrumentation
Software, LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Waters
Industries
Pharma & Biopharma

Constant Neutral Loss, Precursor Ion Scanning, Product Ion Scanning in Support of DMPK Studies Using waters_connect for Quantitation Software Solution and Xevo TQ Absolute XR Mass Spectrometer

Applications
| 2025 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ, Software
Manufacturer
Waters
Industries
Pharma & Biopharma, Clinical Research, Metabolomics
 

Related articles

How is Normal Phase (NP) SPE Different from Reversed-Phase (RP) SPE?
Article | Academy

How is Normal Phase (NP) SPE Different from Reversed-Phase (RP) SPE?

A clear guide to Normal Phase SPE: when to use it, how polar interactions drive retention, and which solvents to choose in increasing polarity—plus a quick reference list for optimized sample preparation.
Phenomenex
tag
share
more
Inertsil Hybrid-C18: Stability Across a Wide pH Range
Article | Product

Inertsil Hybrid-C18: Stability Across a Wide pH Range

Discover how Inertsil Hybrid-C18 brings exceptional stability, wide pH tolerance, and long-term reproducibility to modern LC/MS workflows—now available with a special promotion from Watrex Prague.
Watrex Praha
tag
share
more
Stick and Glue! Tomáš Slanina and his team introduce a new biomolecule-labeling method for more precise observation of cellular processes
Article | Science and research

Stick and Glue! Tomáš Slanina and his team introduce a new biomolecule-labeling method for more precise observation of cellular processes

Researchers at IOCB Prague developed a highly precise and ultra-stable fluorescent labeling method that stays attached even inside cells, enabling long-term, reliable tracking of biomolecules.
Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences
tag
share
more
Sample Preparation Mastery: Expert Insights on Evaporation Techniques for Chromatography
Interview | Video

Sample Preparation Mastery: Expert Insights on Evaporation Techniques for Chromatography

Discover how rotary, centrifugal and freeze-drying techniques compare in modern sample prep. In this expert interview, Wade explains trade-offs in cost, throughput, analyte integrity and automation.
Organomation
tag
share
more
 

Related content

Seized Drug Analysis Using ASAP-MS and Multivariate Analysis Models

Posters
| 2025 | Waters (TIAFT)
Instrumentation
LC/MS, LC/SQ, DART
Manufacturer
Waters
Industries
Forensics

Sensitive and selective quantitation of bile acids using targeted MS2/MS3 on the Stellar mass spectrometer

Posters
| 2025 | Thermo Fisher Scientific (MSACL)
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Clinical Research

Selective and sensitive measurement of 17 steroids in human serum using a Stellar mass spectrometer

Technical notes
| 2025 | Thermo Fisher Scientific
Instrumentation
LC/MS, LC/MS/MS, LC/Orbitrap, LC/HRMS
Manufacturer
Thermo Fisher Scientific
Industries
Clinical Research

Automated Multiple Reaction Monitoring (MRM) Method Development for Peptide Drugs Using waters_connect for Quantitation Software

Applications
| 2025 | Waters
Instrumentation
Software, LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Waters
Industries
Pharma & Biopharma

Constant Neutral Loss, Precursor Ion Scanning, Product Ion Scanning in Support of DMPK Studies Using waters_connect for Quantitation Software Solution and Xevo TQ Absolute XR Mass Spectrometer

Applications
| 2025 | Waters
Instrumentation
LC/MS, LC/MS/MS, LC/QQQ, Software
Manufacturer
Waters
Industries
Pharma & Biopharma, Clinical Research, Metabolomics
 

Related articles

How is Normal Phase (NP) SPE Different from Reversed-Phase (RP) SPE?
Article | Academy

How is Normal Phase (NP) SPE Different from Reversed-Phase (RP) SPE?

A clear guide to Normal Phase SPE: when to use it, how polar interactions drive retention, and which solvents to choose in increasing polarity—plus a quick reference list for optimized sample preparation.
Phenomenex
tag
share
more
Inertsil Hybrid-C18: Stability Across a Wide pH Range
Article | Product

Inertsil Hybrid-C18: Stability Across a Wide pH Range

Discover how Inertsil Hybrid-C18 brings exceptional stability, wide pH tolerance, and long-term reproducibility to modern LC/MS workflows—now available with a special promotion from Watrex Prague.
Watrex Praha
tag
share
more
Stick and Glue! Tomáš Slanina and his team introduce a new biomolecule-labeling method for more precise observation of cellular processes
Article | Science and research

Stick and Glue! Tomáš Slanina and his team introduce a new biomolecule-labeling method for more precise observation of cellular processes

Researchers at IOCB Prague developed a highly precise and ultra-stable fluorescent labeling method that stays attached even inside cells, enabling long-term, reliable tracking of biomolecules.
Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences
tag
share
more
Sample Preparation Mastery: Expert Insights on Evaporation Techniques for Chromatography
Interview | Video

Sample Preparation Mastery: Expert Insights on Evaporation Techniques for Chromatography

Discover how rotary, centrifugal and freeze-drying techniques compare in modern sample prep. In this expert interview, Wade explains trade-offs in cost, throughput, analyte integrity and automation.
Organomation
tag
share
more
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike