Agilent InfinityLab Quick Change Valve G5632A Instructions
Manuals | 2018 | Agilent TechnologiesInstrumentation
Automated multiport valves play a crucial role in modern liquid chromatography workflows by enabling rapid sample handling, enhancing throughput, and improving method flexibility. The Agilent InfinityLab Quick Change Valve G5632A addresses the need for seamless column regeneration, stationary phase switching, and online sample preparation, which are essential in high-performance laboratories across pharmaceuticals, environmental analysis, and bioanalytics.
This document describes the features, installation procedures, and application scenarios of the G5632A 2-position/10-port bio-inert valve head. It aims to guide users through typical workflows—alternating column regeneration, dual column selection, sample enrichment, and cleanup—while ensuring compatibility with Agilent 1290 Infinity modules.
The valve head integrates with Agilent 1290 Infinity Thermostatted Column Compartment, InfinityLab LC Multicolumn Thermostat, or 1290 Infinity Valve Drive. Key components include:
Alternating column regeneration reduces equilibration downtime by up to 50%, enabling continuous operation of one column while regenerating the other. Dual column selection allows rapid changes between different stationary phases or seamless switchover when column performance declines. Sample enrichment and cleanup workflows use pre-columns to concentrate analytes or trap matrix components, improving sensitivity by up to three orders of magnitude and enhancing reproducibility.
Ongoing developments may include integration of multi-valve architectures for higher multiplexing, miniaturized microfluidic valve designs, enhanced RFID-based valve identification, and tighter coupling with mass spectrometry for fully automated, high-sensitivity analyses. Expanded software control and remote diagnostics will drive further efficiency in routine and research laboratories.
The Agilent InfinityLab Quick Change Valve G5632A offers a robust, bio-inert solution for optimizing liquid chromatography workflows. Its versatile port configuration, seamless integration with Agilent modules, and support for advanced sample preparation techniques make it a valuable asset for high-throughput and high-precision analyses.
No specific literature references were provided in the source document.
HPLC
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
Automated multiport valves play a crucial role in modern liquid chromatography workflows by enabling rapid sample handling, enhancing throughput, and improving method flexibility. The Agilent InfinityLab Quick Change Valve G5632A addresses the need for seamless column regeneration, stationary phase switching, and online sample preparation, which are essential in high-performance laboratories across pharmaceuticals, environmental analysis, and bioanalytics.
Objectives and Study Overview
This document describes the features, installation procedures, and application scenarios of the G5632A 2-position/10-port bio-inert valve head. It aims to guide users through typical workflows—alternating column regeneration, dual column selection, sample enrichment, and cleanup—while ensuring compatibility with Agilent 1290 Infinity modules.
Methodology and Instrumentation
The valve head integrates with Agilent 1290 Infinity Thermostatted Column Compartment, InfinityLab LC Multicolumn Thermostat, or 1290 Infinity Valve Drive. Key components include:
- G5632A 2-position/10-port valve head (600 bar, bio-inert PEEK/ceramic liquid contacts)
- PEEK and stainless steel–cladded PEEK capillaries for high-pressure flow paths
- Titanium capillaries and bio-inert fittings for regeneration pump lines
- Dedicated waste tubing and union fittings
Main Results and Discussion
Alternating column regeneration reduces equilibration downtime by up to 50%, enabling continuous operation of one column while regenerating the other. Dual column selection allows rapid changes between different stationary phases or seamless switchover when column performance declines. Sample enrichment and cleanup workflows use pre-columns to concentrate analytes or trap matrix components, improving sensitivity by up to three orders of magnitude and enhancing reproducibility.
Benefits and Practical Applications
- Significant increase in sample throughput and instrument uptime
- Automated gradient separations with minimized idle time
- Enhanced method flexibility through quick stationary phase exchange
- Integrated online cleanup/enrichment for complex matrices (biological fluids, food, environmental samples)
Future Trends and Applications
Ongoing developments may include integration of multi-valve architectures for higher multiplexing, miniaturized microfluidic valve designs, enhanced RFID-based valve identification, and tighter coupling with mass spectrometry for fully automated, high-sensitivity analyses. Expanded software control and remote diagnostics will drive further efficiency in routine and research laboratories.
Conclusion
The Agilent InfinityLab Quick Change Valve G5632A offers a robust, bio-inert solution for optimizing liquid chromatography workflows. Its versatile port configuration, seamless integration with Agilent modules, and support for advanced sample preparation techniques make it a valuable asset for high-throughput and high-precision analyses.
Reference
No specific literature references were provided in the source document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D - Instructions
2018|Agilent Technologies|Manuals
Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D Instructions Quick Change Valves G4231A/C and G4232C/D This technical note describes the installation and application of the Agilent InfinityLab Quick Change 2ps/6pt Valve Heads G4231A/C and 2ps/10pt Valve Heads G4232C/D in a…
Key words
valve, valveexchanger, exchangerquick, quickheat, heatroxpq, roxpqfitting, fittingconnect, connectsxps, sxpsfroxpq, froxpqcolumn, columnstator, statorsocket, socketparts, partshead, headturn
Agilent InfinityLab Quick Change Valve G4239C Instructions
2018|Agilent Technologies|Manuals
Agilent InfinityLab Quick Change Valve G4239C Instructions Agilent InfinityLab Quick Change Valve G4239C Instructions Technical Information about the Agilent Valve Kit G4239C. Contents Typical Applications 2 Multicolumn Selection 2 Method Development 3 Delivery Checklist 3 Install the Valve Heads 8…
Key words
valve, valveexchanger, exchangerfitting, fittingheat, heatstator, statorhead, headcaution, cautionparts, partscolumn, columnplq, plqbypass, bypassinstall, installdamage, damagewaste, wastequick
Your Essential Resource for INFINITYLAB LC SUPPLIES
2020|Agilent Technologies|Brochures and specifications
Your Essential Resource for INFINITYLAB LC SUPPLIES ACROSS THE LAB, AROUND THE WORLD, WITH YOU EVERY STEP OF THE WAY. Real stories from the lab. WHO WE ARE. WHAT WE DO. Whatever your lab needs, Agilent CrossLab is ready to…
Key words
valve, valvesst, sstsupplies, suppliespeek, peekdescription, descriptionfitting, fittingpreswaged, preswagedinfinitylab, infinitylabcapillaries, capillariesbio, biokit, kitkits, kitspump, pumpstainless, stainlessseal
Agilent InfinityLab Quick Change Valve G5641A - Instructions
2021|Agilent Technologies|Manuals
Agilent InfinityLab Quick Change Valve G5641A Instructions This technical note describes the installation and application of the Agilent InfinityLab Quick Change 2-position/10-port Bio Valve G5641A in a 1290 Infinity II Multicolumn Thermostat (MCT). Typical Applications 2 Dual Column Selection (2-Position/6-Port…
Key words
valve, valveinstallation, installationstator, statorpump, pumpparts, partsquick, quickexchanger, exchangerfitting, fittingcolumn, columnhead, headconnect, connectenrichment, enrichmentwaste, wasteheat, heatcapillary