Multi-Dimensional LC/MS Using Orthogonal Reversed-Phase Stationary Phases

Presentations |  | MerckInstrumentation
LC/MS, 2D-LC
Industries
Manufacturer
Merck

Summary

Importance of the Topic


Multi-dimensional liquid chromatography coupled with mass spectrometry (LC/MS) leverages multiple molecular interactions to achieve separations that cannot be obtained on a single chromatographic mechanism. In complex samples—such as protein digests, environmental mixtures or pharmaceutical impurities—this approach enhances resolution, improves peak capacity and enables the detection of low-abundance components without extensive sample preparation or ion-pair reagents.

Objectives and Study Overview


This work explores orthogonal reversed-phase stationary phases to create multi-dimensional LC/MS separations. The goals are to:
  • Compare methods that layer additional interactions onto a conventional C18 separation.
  • Evaluate two-dimensional systems using distinctly different and complementary reversed-phase chemistries.
  • Demonstrate multi-dimensional separations on a single, mixed-mode stationary phase.

Models include tryptic digests of β-galactosidase and mixtures of basic and neutral small molecules to illustrate retention and selectivity differences.

Methodology and Instrumentation


This study employed:
  • Ion-exchange (IEX) and reversed-phase (RP) columns (C18, C8, fluorinated Phenyl F5).
  • Two-dimensional configurations: IEX → RP fractionation, distinct mobile phase adjustments for each dimension.
  • Complementary RP coupling: C18 paired with C8 or F5 under a single solvent gradient.
  • Single-column, mixed-mode RP phases enabling dispersive, polar and ionic interactions.
  • High-performance LC system with electrospray ionization mass spectrometer (ESI-MS).
  • Mobile phase: 20 mM ammonium acetate (pH 6.7) and acetonitrile at varying ratios; flow rate 1 mL/min; column temperature 35 °C; injection volume 10 µL.

Main Results and Discussion


1. Addition of ion-pair reagents to C18 allowed ionic retention but compromised LC/MS sensitivity and reproducibility.
2. Distinct two-dimensional IEX→C18 separations achieved effective fractionation of complex peptides, demonstrated by increased peak density in a β-galactosidase digest.
3. Coupling complementary RP phases (C18 vs. C8) under identical gradients yielded similar selectivity, offering limited benefit. By contrast, pairing C18 with HS F5 produced divergent retention orders for basic and neutral compounds, indicating greater orthogonality.
4. Mixed-mode RP phases (HS F5) displayed U-shaped retention profiles across high-to-low organic content, enabling simultaneous exploitation of hydrophobic, dipole and ionic interactions without ion-pair agents.
5. Single-column multi-dimensional separations on polar-RP phases proved flexible and robust, reducing method development complexity while delivering unique selectivity for diverse analyte classes.

Benefits and Practical Applications


Using orthogonal reversed-phase phases or mixed-mode stationary phases in LC/MS:
  • Enhances separation of peptides, polar small molecules and basic drugs without derivatization.
  • Reduces sample complexity via two-dimensional fractionation while maintaining MS compatibility.
  • Eliminates nonvolatile ion-pair reagents, improving sensitivity and reproducibility in ESI-MS.
  • Simplifies workflows by selecting a single mixed-mode phase when appropriate, streamlining mobile phase optimization.

Future Trends and Applications


Advances likely to emerge include:
  • Novel hybrid stationary phases with tailored ligand densities for fine-tuned dispersive, polar and ionic retention.
  • Automated two- or three-dimensional LC systems integrating in-line switching valves and intelligent gradient programming.
  • Integration with high-resolution MS and data-independent acquisition to fully exploit increased peak capacity.
  • Applications in omics, biopharmaceutical impurity profiling and environmental trace analysis requiring high selectivity and sensitivity.

Conclusion


Multi-dimensional LC/MS based on orthogonal reversed-phase chemistries demonstrates significant gains in separation power and MS compatibility. While traditional two-column approaches deliver robust fractionation, single-column mixed-mode phases emerge as a versatile alternative for rapid method development. Selecting the appropriate stationary phase chemistry is key to achieving target resolution without sacrificing throughput or sensitivity.

References


No specific literature citations were provided in the original text.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Troubleshooting Liquid Chromatographic Separations: Avoiding Common Issues through Informed Method Development Practices
Troubleshooting Liquid Chromatographic Separations: Avoiding Common Issues through Informed Method Development Practices Dave S. Bell Supelco, Div. of Sigma-Aldrich Bellefonte, PA 16823 USA sigma-aldrich.com/analytical T414096 © 2014 Sigma-Aldrich Co. All rights reserved. Objective •Most of the difficult problems encountered are…
Key words
rightsall, rightsallaldrich, aldrichsigma, sigmainteractions, interactionsphases, phasesselectivity, selectivitypolar, polarstationary, stationaryavailability, availabilitysilanol, silanolstrong, strongepg, epgmoderate, moderateruggedness, ruggednessphase
HPLC Column Comparison Screening Study for Reversed Phase Columns
HPLC Column Comparison Screening Study for Reversed Phase Columns Carmen T. Santasania, David S. Bell, and Tracy L. Ascah-Ross Supelco, 595 North Harrison Road, Bellefonte, PA 16823, USA T403157 GIB Introduction The selection of the proper HPLC column for any…
Key words
phenacetin, phenacetincodeine, codeinecyano, cyanostudy, studyselectivity, selectivityscreening, screeningcolumn, columnphases, phasesalpha, alphaphase, phasechosen, chosenhplc, hplcsystematic, systematicgib, gibpredicted
HPLC Column Comparison Screening Study for Reversed Phase Columns
HPLC Column Comparison Screening Study for Reversed Phase Columns Carmen T. Santasania, Eric M. Snyder, Matilal Sarker, and Tracy L. Ascah Supelco, 595 North Harrison Road, Bellefonte, PA 16823, USA T403058 2 Introduction When developing a new HPLC method, selecting…
Key words
phenacetin, phenacetincodeine, codeineselectivity, selectivityscreening, screeningstudy, studycyano, cyanophases, phasespredicted, predicteddifferences, differencesalpha, alphacolumn, columnapplying, applyingdiscovery, discoveryretention, retentioncompounds
Stability and Performance of Cyano Bonded Phase HPLC Columns for Reversed-Phase, Normal-Phase and HILIC Applications
Stability and Performance of Cyano Bonded Phase HPLC Columns for Reversed-Phase, Normal-Phase and HILIC Applications Richard A. Henry, Carmen T. Santasania, William H. Campbell and Wendy Roe sigma-aldrich.com T410171 Fundamentals of Ascentis® ES Cyano R. A. Henry EAS 2010 2…