Soft Ionization GC Coupling to LC-MS Systems
Brochures and specifications | 2021 | PlasmionInstrumentation
Gas chromatography (GC) paired with mass spectrometry (MS) is a cornerstone of routine analytical practice, yet many sample matrices demand both GC-MS and liquid chromatography-MS (LC-MS) to span the full spectrum of target analytes. Traditional approaches requiring separate instrumentation drive up capital expenditure, laboratory footprint and maintenance efforts. The integration of soft ionization GC coupling on LC-MS platforms addresses these challenges by uniting comprehensive analyte coverage with high sensitivity and selectivity in a single workflow.
This work presents the SICRIT® soft plasma ionization source as a versatile, cost-effective interface enabling direct GC analysis on existing LC-MS systems. Key objectives include:
The SICRIT® ion source relies on a dielectric barrier discharge cold plasma generated in a confined capillary, minimizing ion loss and fragmentation. Core components:
Soft plasma ionization achieved excellent sensitivity and minimal fragmentation across diverse analyte classes. Key findings:
Comparative spectra confirm that SICRIT® produces almost no fragmentation versus traditional electron ionization, while covering much of the ionization range of APCI and parts of ESI and EI.
The GC-SICRIT®-MS workflow delivers:
Applications include pesticide residue quantification, environmental contaminant screening, food safety and forensic toxicology.
Advances may include integration with GCxGC for enhanced separation, coupling to novel high-resolution MS architectures, and incorporation of AI-driven data analysis for rapid non-target feature identification. Expansion toward semi-volatile and mid-polar biomolecules could further broaden application scope.
The SICRIT® soft plasma GC-MS interface transforms existing LC-MS instruments into dual-mode platforms, combining the strengths of GC and LC-MS. Its high sensitivity, minimal fragmentation and broad ionization range offer streamlined workflows, cost savings and robust performance for both targeted and non-targeted analyses.
GC/MSD, GC/API/MS, LC/MS
IndustriesManufacturerPlasmion
Summary
Importance of the topic
Gas chromatography (GC) paired with mass spectrometry (MS) is a cornerstone of routine analytical practice, yet many sample matrices demand both GC-MS and liquid chromatography-MS (LC-MS) to span the full spectrum of target analytes. Traditional approaches requiring separate instrumentation drive up capital expenditure, laboratory footprint and maintenance efforts. The integration of soft ionization GC coupling on LC-MS platforms addresses these challenges by uniting comprehensive analyte coverage with high sensitivity and selectivity in a single workflow.
Goals and study overview
This work presents the SICRIT® soft plasma ionization source as a versatile, cost-effective interface enabling direct GC analysis on existing LC-MS systems. Key objectives include:
- Demonstrating seamless coupling of any GC or GCxGC system to high-resolution (TOF, Orbitrap) or triple quadrupole LC-MS instruments
- Evaluating soft ionization performance for non-target screening and routine quantification
- Illustrating expanded analyte coverage via real-world applications (n-alkanes, PCBs, nitrosamines)
Methodology and used instrumentation
The SICRIT® ion source relies on a dielectric barrier discharge cold plasma generated in a confined capillary, minimizing ion loss and fragmentation. Core components:
- SICRIT® Ion Source with cold plasma for fragment-free ionization
- GC/SPME Module and heated transfer line for gas-tight, loss-free sample transfer
- SICRIT® SC-30 Control Unit for precise plasma and module parameter management
- Vendor-specific MS interfaces to connect to Thermo Fisher, Agilent, SCIEX, Bruker, Waters, Shimadzu and JEOL systems
- Examples of third-party equipment: Agilent 8860 GC, CTC PAL RTC autosampler
Main results and discussion
Soft plasma ionization achieved excellent sensitivity and minimal fragmentation across diverse analyte classes. Key findings:
- n-Alkanes: clear [M]+ molecular ions with accurate molecular weight determination
- PCBs: intact molecular ions with isotopic patterns enabling unambiguous identification
- Nitrosamines: low nanogram-per-milliliter limits of detection using MRM transitions on a triple quadrupole
- Non-target screening: high resolution TOF/Orbitrap data deliver unmatched selectivity for unknowns in complex matrices
Comparative spectra confirm that SICRIT® produces almost no fragmentation versus traditional electron ionization, while covering much of the ionization range of APCI and parts of ESI and EI.
Benefits and practical applications
The GC-SICRIT®-MS workflow delivers:
- Consolidated instrument platform reducing capital and operational costs
- Reduced sample preparation and data integration efforts by avoiding separate GC-MS and LC-MS analyses
- Flexible coupling to meet tasks requiring either targeted quantification (MRM) or comprehensive non-target screening
Applications include pesticide residue quantification, environmental contaminant screening, food safety and forensic toxicology.
Future trends and potential uses
Advances may include integration with GCxGC for enhanced separation, coupling to novel high-resolution MS architectures, and incorporation of AI-driven data analysis for rapid non-target feature identification. Expansion toward semi-volatile and mid-polar biomolecules could further broaden application scope.
Conclusion
The SICRIT® soft plasma GC-MS interface transforms existing LC-MS instruments into dual-mode platforms, combining the strengths of GC and LC-MS. Its high sensitivity, minimal fragmentation and broad ionization range offer streamlined workflows, cost savings and robust performance for both targeted and non-targeted analyses.
References
- NIST Chemistry WebBook, NIST Standard Reference Database Number 69; available at https://webbook.nist.gov/chemistry/
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
An Integrated Solution to Speed up Routine Analysis
2021|Plasmion|Brochures and specifications
An Integrated Solution to Speed up Routine Analysis Maximize sample throughput while upholding rigor quantification Integrated Rather than Separated Solution The tedious sample preparation combined with the long analysis times make it very complex to handle the increasing volume of…
Key words
sicrit, sicritplasmion‘s, plasmion‘sspme, spmeenables, enablesplasmion, plasmionworkflows, workflowspal, palnegative, negativeroutine, routinedirect, directsource, sourcesolution, solutionmodule, moduleionization, ionizationintegrated
SICRIT ® – The Ion Source for Direct MS Measurements
2021|Plasmion|Brochures and specifications
SICRIT – The Ion Source for Direct MS Measurements ® Upgrade your MS into a sensitive VOC sensor for fast screening or 24/7 monitoring Simplifying Mass Spectrometry Direct MS has shown its potential for fast screening analysis and for real-time…
Key words
sicrit, sicritdirect, directsource, sourcehoney, honeyabundance, abundanceplasmion‘s, plasmion‘sion, ionplasmion, plasmionrelative, relativeionization, ionizationconnection, connectionenables, enablespal, palbio, biosampling
The SICRIT® Solution for Breath Analysis
2021|Plasmion|Brochures and specifications
The SICRIT® Solution for Breath Analysis Biomarker discovery in exhaled breath enabling non invasive clinical diagnostics based on direct MS Cutting Edge Breath Analysis The most promising approach in non invasive clinical diagnostics is the analysis of exhaled breath It…
Key words
sicrit, sicritbreath, breathionization, ionizationplasmion, plasmionexhaled, exhaledplasmion‘s, plasmion‘sbiomarker, biomarkersampling, samplinginvasive, invasivesoft, softsource, sourcebased, baseddiagnostics, diagnosticsenables, enablesdisposable
Plasmion SICRIT® Ionization Set SC-30
2020|Plasmion|Brochures and specifications
Product Note SICRIT® Ionization Set SC-30 The SICRIT® Ionization Set SC-30 upgrades any LC-MS instrument with a plug & play ionization source. The SICRIT® soft ionization technology enables PTR-like online MS-measurements as well as coupling of sample enrichment and/or chromatographic…
Key words
sicrit, sicritsoft, softsource, sourceion, ionplasmion‘s, plasmion‘sionization, ionizationinterfaces, interfacesspme, spmemeasurements, measurementsreserved, reserveddirect, directyour, yourrights, rightsplasma, plasmaoperation