Enhancing the data quality by high-speed analysis on a single quadrupole mass spectrometer
Posters | 2021 | Shimadzu | ASMSInstrumentation
The adoption of ultra-high-performance liquid chromatography (UHPLC) has driven a need for mass spectrometers capable of matching its high separation speed and narrow peak profiles. Without sufficiently fast data acquisition, chromatographic resolution gains are lost due to peak broadening and incomplete detection. Integrating ultrafast scanning and rapid polarity switching in a single-quadrupole mass spectrometer addresses this gap, enhancing both throughput and data quality in pharmaceutical and analytical applications.
This study evaluated the impact of varying scan speeds and positive/negative polarity switching rates on the chromatographic resolution and detection of a 12-component pharmaceutical mixture. Using Shimadzu’s Nexera XR UHPLC coupled to a modified LCMS-2020, the authors aimed to determine optimal operating parameters for high-speed analysis without compromising signal integrity or peak shape.
A mixed standard containing papaverine, propranolol, diphenhydramine, dipyridamole, amitriptyline, reserpine, chloramphenicol, sulfadimethoxine, furosemide, carbamazepine, isopropyl antipyrine and nitrendipine (10 mg/L each) was separated on UHPLC using a gradient from 10 % to 100 % acetonitrile over 20 min at 0.3 mL/min and 40 °C. Mass spectra were acquired in SCAN mode (m/z 100–1000) with polarity switching. Peak widths at half maximum were compared across scan speeds. In-source collision-induced dissociation (CID) experiments generated fragment information for reserpine.
The modified single-quadrupole LCMS-2020 coupled to UHPLC demonstrated that ultrafast scan speeds and rapid polarity switching significantly improve chromatographic peak shape and compound resolution. In-source CID provided valuable structural insights in a streamlined workflow, making this platform highly suitable for high-throughput pharmaceutical and analytical chemistry applications.
LC/MS, LC/SQ
IndustriesPharma & Biopharma
ManufacturerShimadzu
Summary
Significance of the Topic
The adoption of ultra-high-performance liquid chromatography (UHPLC) has driven a need for mass spectrometers capable of matching its high separation speed and narrow peak profiles. Without sufficiently fast data acquisition, chromatographic resolution gains are lost due to peak broadening and incomplete detection. Integrating ultrafast scanning and rapid polarity switching in a single-quadrupole mass spectrometer addresses this gap, enhancing both throughput and data quality in pharmaceutical and analytical applications.
Objectives and Study Overview
This study evaluated the impact of varying scan speeds and positive/negative polarity switching rates on the chromatographic resolution and detection of a 12-component pharmaceutical mixture. Using Shimadzu’s Nexera XR UHPLC coupled to a modified LCMS-2020, the authors aimed to determine optimal operating parameters for high-speed analysis without compromising signal integrity or peak shape.
Used Instrumentation
- UHPLC system: Nexera XR with XR-ODS column (50 × 2.0 mm, 2.2 µm)
- Autosampler: SIL-40C XR; Column oven: CTO-40C
- Detector: SPD-M40 photodiode array
- Mass spectrometer: Modified LCMS-2020 quadrupole with ESI/APCI ion sources
- Scan speeds tested: 7,500; 10,000; 15,000 u/sec
- In-source CID: Qarray voltage increased to 120 V for pseudo-MS/MS
Methodology
A mixed standard containing papaverine, propranolol, diphenhydramine, dipyridamole, amitriptyline, reserpine, chloramphenicol, sulfadimethoxine, furosemide, carbamazepine, isopropyl antipyrine and nitrendipine (10 mg/L each) was separated on UHPLC using a gradient from 10 % to 100 % acetonitrile over 20 min at 0.3 mL/min and 40 °C. Mass spectra were acquired in SCAN mode (m/z 100–1000) with polarity switching. Peak widths at half maximum were compared across scan speeds. In-source collision-induced dissociation (CID) experiments generated fragment information for reserpine.
Main Results and Discussion
- At 15,000 u/sec, all 12 compounds were resolved with sharp peaks (~0.78–1.08 s half-width).
- Lower scan speeds (7,500 and 10,000 u/sec) caused broader peaks, loss of peak 2 and coelution of peaks 3 & 4 (positive mode) and 7 & 8 (negative mode).
- In-source CID on reserpine produced characteristic fragments at m/z 397, 195 and 174, confirming structural sites in a single-scan experiment.
Benefits and Practical Applications
- Enables full utilization of UHPLC resolution for complex mixtures in pharmaceutical analysis.
- Combines positive/negative ion detection in one injection, reducing analysis time.
- Pseudo-MS/MS structural data acquisition without a dedicated tandem MS instrument.
- Supports QA/QC workflows requiring high throughput and reliable quantitation.
Future Trends and Opportunities
- Further increases in scan speed and acquisition duty cycle to match evolving chromatographic performance.
- Integration with high-resolution MS for precise mass confirmation alongside ultrafast scanning.
- Application to metabolomics, environmental testing and food safety where rapid profiling is essential.
- Implementation of AI-driven peak detection and deconvolution to maximize data throughput.
Conclusion
The modified single-quadrupole LCMS-2020 coupled to UHPLC demonstrated that ultrafast scan speeds and rapid polarity switching significantly improve chromatographic peak shape and compound resolution. In-source CID provided valuable structural insights in a streamlined workflow, making this platform highly suitable for high-throughput pharmaceutical and analytical chemistry applications.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Evaluation of MS Scanning Speeds with UHPLC Peak Widths
|Shimadzu|Presentations
Evaluation of MS Scanning Speeds with UHPLC Peak Widths William Hedgepeth, Masatoshi Takahashi, Shimadzu Scientific Instruments Introduction The trend toward high-speed LC analysis with reduced column particle sizes continues to increase in popularity. The narrow peak widths of high-speed LC…
Key words
speed, speedscan, scandaimuron, daimuroncarpropamid, carpropamidnegative, negativepositive, positivescanning, scanningpeak, peakneg, negpos, posion, iontrycropyr, trycropyrbentazone, bentazonehigh, highproton
Shimadzu Liquid Chromatograph Mass Spectrometer LCMS-2050
2024|Shimadzu|Brochures and specifications
C146-E442 Liquid Chromatograph Mass Spectrometer LCMS-2050 Seamless integration with LC by design Superior detection for added confidence Streamlined operation for cost efficiency The LCMS-2050 provides both high speed and high sensitivity analysis even in a small design. We have achieved…
Key words
polarity, polarityswitching, switchingmass, massshimadzu, shimadzuseamless, seamlession, ionpositive, positivemin, minshutdown, shutdownmeasurements, measurementsdata, dataheated, heatedfaq, faqchromatograms, chromatogramsconsumption
Development of fast scanning technologies for a triple quadrupole mass spectrometer
2011|Shimadzu|Posters
Development of fast scanning technologies for a triple quadrupole mass spectrometer ASMS 2011 ThP04 Daisuke Okumura, Shiro Mizutani, Hiroto Itoi SHIMADZU CORPORATION, Nishinokyo-kuwabaracho, Nakagyo-ku, Kyoto 604-8511, Japan Development of fast scanning technologies for a triple quadrupole mass spectrometer Introduction Methods…
Key words
quadrupole, quadrupoleion, iontriple, triplescanning, scanningspeed, speedscan, scanfast, fastsupply, supplymass, massdispersion, dispersiondevelopment, developmenttechnologies, technologiesrods, rodspower, powerspectrometer
Shimadzu LCMS-2020
2021|Shimadzu|Brochures and specifications
C146-E121G Liquid Chromatograph Mass Spectrometer LCMS-2020 LCMS-2020 —Seeing is Believing. Ultra Fast UFswitching™ Rapid 15 msec Polarity Switching Ultra Fast UFsensitivity™ Superior Sensitivity with UHPLC Ultra Fast UFscanning™ 15,000 u/sec Fast Scanning Speed Speed is Power. Greater speed. Greater sensitivity.…
Key words
ufscanning, ufscanningultra, ultraerythromycin, erythromycinufswitching, ufswitchingpositive, positivedymuron, dymuronfast, fastcid, cidbrowser, browserswitching, switchingpurification, purificationnegative, negativeion, iondisplays, displaysdata