MassHunter Walkup System - Quick Start Guide
Manuals | 2017 | Agilent TechnologiesInstrumentation
MassHunter Walkup System streamlines sample submission and analysis on Agilent LC and LC/MS instruments, enabling nonexpert users to run complex methods in central analytical laboratories. It automates queuing, method selection, and result delivery, supporting high-throughput demands in pharmaceutical, environmental, petrochemical, and food testing.
This Quick Start Guide for version C.03.01 introduces core workflows: launching Walkup via OpenLAB CDS or MassHunter Data Acquisition, submitting and reprocessing samples locally and remotely, managing sample queues and events, and accessing online help and administration utilities.
Walkup features a ribbon interface, status bar, sample queue table, plate-tray diagram, and optional fraction-collection pane. Administrators configure user access, workflows, data paths, injection volumes, email reporting preferences, and run-group protocols. Users submit samples through a three-page wizard, specifying methods, priorities, and sample metadata.
Version C.03.01 adds support for OpenLAB CDS A.02.03/A.02.2, ChemStation Edition C.01.08, new LC/MS modules, enhanced fraction collection features, customizable data organization, selective email of results, remote workload monitoring, and flexible run-group options including overlaps and equilibration.
By simplifying instrument operation, Walkup reduces user training requirements and errors. Self-service sample submission and centralized administration accelerate workflows, improve data consistency, and offer automated email reporting. Fraction collection and run-group management further expand preparative and analytical capabilities.
Integration with laboratory information management systems and cloud platforms can enhance sample tracking and data sharing. Advanced workload balancing, AI-driven scheduling, and mobile interfaces may further optimize throughput and accessibility across distributed facilities.
Agilent MassHunter Walkup System C.03.01 delivers an intuitive, secure, and scalable solution for core analytical labs. Its broad instrument compatibility, flexible configuration, and comprehensive management tools support efficient high-throughput chromatography and LC/MS operations.
Software
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
MassHunter Walkup System streamlines sample submission and analysis on Agilent LC and LC/MS instruments, enabling nonexpert users to run complex methods in central analytical laboratories. It automates queuing, method selection, and result delivery, supporting high-throughput demands in pharmaceutical, environmental, petrochemical, and food testing.
Objectives and Overview
This Quick Start Guide for version C.03.01 introduces core workflows: launching Walkup via OpenLAB CDS or MassHunter Data Acquisition, submitting and reprocessing samples locally and remotely, managing sample queues and events, and accessing online help and administration utilities.
Methodology and Instrumentation
Walkup features a ribbon interface, status bar, sample queue table, plate-tray diagram, and optional fraction-collection pane. Administrators configure user access, workflows, data paths, injection volumes, email reporting preferences, and run-group protocols. Users submit samples through a three-page wizard, specifying methods, priorities, and sample metadata.
Used Instrumentation
- Agilent InfinityLab 1260/1290 Infinity II LC modules: Preparative Binary Pump, Autosampler, Valve-Based Collector, Column Valve Module, Active Splitter
- Agilent MSD and MSD XT detectors
- MassHunter Data Acquisition for Q-TOF (B.08.00 SP1, B.08.01 SP1)
- MassHunter BioConfirm B.09.00
- Fraction Collector models G7159B, G7166A, G1364A–G1364F
Key Results and Discussion
Version C.03.01 adds support for OpenLAB CDS A.02.03/A.02.2, ChemStation Edition C.01.08, new LC/MS modules, enhanced fraction collection features, customizable data organization, selective email of results, remote workload monitoring, and flexible run-group options including overlaps and equilibration.
Benefits and Practical Applications
By simplifying instrument operation, Walkup reduces user training requirements and errors. Self-service sample submission and centralized administration accelerate workflows, improve data consistency, and offer automated email reporting. Fraction collection and run-group management further expand preparative and analytical capabilities.
Future Trends and Opportunities
Integration with laboratory information management systems and cloud platforms can enhance sample tracking and data sharing. Advanced workload balancing, AI-driven scheduling, and mobile interfaces may further optimize throughput and accessibility across distributed facilities.
Conclusion
Agilent MassHunter Walkup System C.03.01 delivers an intuitive, secure, and scalable solution for core analytical labs. Its broad instrument compatibility, flexible configuration, and comprehensive management tools support efficient high-throughput chromatography and LC/MS operations.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
MassHunter Study Manager for Ultivo LC/TQ - Quick Start Guide
2017|Agilent Technologies|Manuals
MassHunter Study Manager for Ultivo LC/TQ Quick Start Guide What is MassHunter Study Manager? 2 Help 2 Documents 2 User Interface 3 Home Tab in the Ribbon 4 Settings Tab in the Ribbon 5 Current/Stopped Study Pane 7 Pending Studies…
Key words
study, studyultivo, ultivoworklist, worklistmanager, managerguide, guidestart, startquick, quickagilent, agilentsubmit, submitpending, pendingclick, clickqueue, queuewizard, wizardstudies, studiesexercise
MassHunter Study Manager - Quick Start Guide
2018|Agilent Technologies|Manuals
MassHunter Study Manager Quick Start Guide What is MassHunter Study Manager? 2 Help 2 User Interface 3 Home tab on the ribbon 4 Settings tab on the ribbon 5 Current/Stopped Study Pane 7 Pending Studies tab 7 Completed Studies tab…
Key words
study, studyworklist, worklistmanager, managermasshunter, masshunterwizard, wizardstart, startguide, guidequick, quickpending, pendingsubmit, submitimport, importqueue, queuestudies, studiesclick, clicksubmitting
MassHunter Study Manager for K6460 and K6420 - Quick Start Guide
2018|Agilent Technologies|Manuals
MassHunter Study Manager for K6460 and K6420 Quick Start Guide For In Vitro Diagnostic Use The K6460 and K6420 mass spectrometers are intended to be used to identify inorganic or organic compounds in human specimens by ionizing the compounds and…
Key words
worklist, workliststudy, studywizard, wizardpending, pendingimport, importqueue, queueclick, clicksubmit, submitstudies, studiessubmitting, submittingpage, pageoptional, optionalexercise, exercisebioanalysis, bioanalysisfamiliarization
Agilent MassHunter Study Manager - Quick Start Guide
2012|Agilent Technologies|Manuals
Agilent MassHunter Study Manager Quick Start Guide What is MassHunter Study Manager? 2 Help 2 Documents 2 User Interface 3 Home Tab in the Ribbon 4 Settings Tab in the Ribbon 6 Current/Stopped Study Pane 8 Pending Studies Tab 8…
Key words
study, studyworklist, worklistmanager, managerguide, guidestart, startquick, quickwizard, wizardagilent, agilentpending, pendingsubmit, submitimport, importclick, clickqueue, queuestudies, studiespage