Thermo Scientific UltiMate 3000 Variable Wavelength Detectors

Brochures and specifications | 2010 | Thermo Fisher ScientificInstrumentation
HPLC
Industries
Manufacturer
Thermo Fisher Scientific

Summary

Importance of the Topic


The UltiMate 3000 VWD-3000 series variable wavelength UV-Vis detectors address key analytical challenges in modern liquid chromatography by combining high sensitivity, broad dynamic range and full compatibility with UHPLC workflows. Their advanced optics and automated qualification features ensure reliable, high-precision detection required across pharmaceutical, environmental and industrial laboratories.

Objectives and Overview


This document reviews the design principles, performance metrics and operational features of the VWD-3000 detectors. It aims to demonstrate how forward optics monochromators, rapid data collection and integrated software support optimize trace‐level quantification, multiwavelength screening and preventive maintenance in routine and high-throughput analyses.

Methodology and Instrumentation


The detectors use a fast-tuning grating monochromator ahead of the flow cell to minimize stray light and enhance baseline stability. A dedicated reference photodiode and active lamp temperature control reduce drift. Two lamp types (deuterium and tungsten) cover 190–900 nm on one optical axis, supporting both UV and visible detection.

Instrumentation

  • Models: VWD-3100 (100 Hz), VWD-3400RS (200 Hz) for rapid separation LC
  • Light sources: combined deuterium and tungsten lamps with temperature-controlled lamp house
  • Flow cells: eight options (3 nL to 11 µL) in PEEK™, stainless steel or fused silica for nano to semi-preparative flows
  • Software: Chromeleon® for data acquisition, automated qualification, wavelength verification and predictive maintenance alerts


Main Results and Discussion

  • Baseline noise <±2.5 µAU at 254 nm (1 s time constant) and drift <100 µAU/h
  • Linearity up to 2.5 AU with correlation coefficients >0.9999 and RSD <0.3%
  • Data collection rates up to 200 Hz (single wavelength) and 5 Hz (up to four simultaneous wavelengths)
  • Automated wavelength switching <250 ms supports multiwavelength UHPLC methods
  • Predictive lamp and flow-cell replacement based on integrated ID chips and software monitoring


Benefits and Practical Applications

  • Accurate trace-level quantification without sample enrichment
  • Flexible method development via spectral scanning and multiwavelength detection
  • Regulatory compliance ensured by automated qualification and holmium filter verification
  • Enhanced uptime through ergonomic, tool-free lamp and cell exchange and predictive maintenance


Future Trends and Possibilities

  • Further integration with ultrafast UHPLC methods requiring sub-second peak resolution
  • Expansion of multiwavelength and full-spectrum detection capabilities
  • Enhanced automation of QC routines and self-diagnostics driven by AI-based data interpretation
  • Development of compact detectors for in-line process monitoring in biopharmaceutical and environmental applications


Conclusion


The UltiMate 3000 VWD-3000 series delivers robust UV-Vis detection with exceptional noise performance, linearity and flexibility for a wide range of LC applications. Coupled with powerful software tools for qualification and maintenance, these detectors offer laboratories a dependable solution for improving throughput, data quality and operational efficiency.

References


  • Dionex Corporation. UltiMate 3000 VWD-3000 Series UV-Vis Detectors Application Note. 2010.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors - Product Specifications
C H R O M ATO G R A P H Y Product Sp e ci f i ca t i ons Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors Integrating hardware, software and separation chemistry, we offer UHPLC to…
Key words
qualification, qualificationlamp, lampmau, mauwavelength, wavelengthminutes, minutesmonitoring, monitoringdionex, dionexcells, cellsflow, flowanalog, analogdetection, detectionchromeleon, chromeleonconductivity, conductivitysuperior, superioraccurate
Thermo Scientific Dionex UltiMate 3000 Diode Array and Multiple-Wavelength Detectors - Product Specifications
C H R O M ATO G R A P H Y Fast, sensitive, and rugged UV-Vis detection Produ c t Spe ci f i cat i ons Thermo Scientific Dionex UltiMate 3000 Diode Array and Multiple-Wavelength Detectors Integrating hardware,…
Key words
lamps, lampswavelength, wavelengthcells, cellstungsten, tungstenspectral, spectralmwd, mwddeuterium, deuteriumlamp, lampchromeleon, chromeleonslit, slitdetectors, detectorsflow, flowdetector, detectornoise, noiselibraries
Thermo UltiMate 3000 Variable Wavelength Detectors VWD-3100 and VWD-3400RS
Thermo Scientific Dionex UltiMate 3000 Series Variable Wavelength Detectors VWD-3100 and VWD-3400RS Operating Instructions (Original Operating Instructions) Revision: 1.7 Date: September 2013 © 2013 Thermo Fisher Scientific Inc. Doc No. 4820.7451 UltiMate 3000 Series: VWD-3100 and VWD-3400RS Variable Wavelength Detectors…
Key words
instructions, instructionsoperating, operatinglamp, lampchromeleon, chromeleondetector, detectorcell, cellremedial, remedialwavelength, wavelengthflow, flowdes, desfailed, faileddigital, digitalpanel, paneldisplay, displayaction
Thermo Scientific Vanquish Variable Wavelength Detectors - PRODUCT SPECIFICATIONS
Thermo Scientific Vanquish Variable Wavelength Detectors - PRODUCT SPECIFICATIONS
2021|Thermo Fisher Scientific|Brochures and specifications
PRODUCT SPECIFICATIONS Vanquish Variable Wavelength Detectors The collective power of chromatography LC that takes your productivity to new heights Vanquish platform benefits High-performance UV-Vis detection • Precision and reproducibility to meet every application demand Thermo Scientific™ Vanquish™ Variable Wavelength Detectors…
Key words
lamp, lampwavelength, wavelengthdeuterium, deuteriumvanquish, vanquishtungsten, tungstenvariable, variablechannel, channelnoise, noisevis, visdetector, detectorvwds, vwdslinearity, linearitychannels, channelspartnumber, partnumberdrift
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike