Thermo Scientific Vanquish Diode Array Detectors and Multi Wavelength Detectors - PRODUCT SPECIFICATIONS
Brochures and specifications | 2019 | Thermo Fisher ScientificInstrumentation
Diode array and multiple wavelength detectors are essential tools in liquid chromatography workflows, offering detailed spectral data for qualitative and quantitative analysis of complex samples. Their ability to detect analytes over a broad dynamic range with high sensitivity and reproducibility is critical in pharmaceutical, environmental, food safety, and chemical research laboratories
This summary reviews the features and performance of Thermo Scientific Vanquish DAD and MWD series detectors, outlining the design principles, operational capabilities, and application flexibility of the HL, FG, CG diode array detectors and the CG multiple wavelength detector from the Vanquish platform
The Vanquish DADs and MWDs employ a single-beam reverse-optics layout with concave holographic gratings and achromatic lenses focusing light onto a 1024 element photodiode array. The primary light sources include deuterium lamps for UV range detection and tungsten lamps for VIS range extension. Optical parameters such as slit width can be adjusted from 1 to 8 nm, and internal calibration uses the D-alpha line; validation relies on a holmium oxide filter. Data acquisition rates reach up to 250 Hz for 3D spectra and up to 200 Hz for scanning. System health is monitored through power-up diagnostics, leak detection and predictive maintenance features integrated with Chromeleon CDS software GLP functions
Advancements in miniaturized detectors, extended wavelength coverage into the UV-VIS-NIR regions and real-time chemometric analysis are expected to drive next-generation chromatographic detection. Integration with artificial intelligence for automated data interpretation and remote system monitoring will further streamline laboratory workflows
Thermo Scientific Vanquish DAD and MWD detectors combine precision optics, robust engineering and intelligent diagnostics to deliver high sensitivity, linearity and flexibility across diverse liquid chromatography applications. Their modular design and predictive maintenance features ensure long-term performance and minimal downtime for quality-critical analyses
Thermo Fisher Scientific Inc. Product Specification PS73047-EN
HPLC
IndustriesManufacturerThermo Fisher Scientific
Summary
Significance of Topic
Diode array and multiple wavelength detectors are essential tools in liquid chromatography workflows, offering detailed spectral data for qualitative and quantitative analysis of complex samples. Their ability to detect analytes over a broad dynamic range with high sensitivity and reproducibility is critical in pharmaceutical, environmental, food safety, and chemical research laboratories
Objectives and Study Overview
This summary reviews the features and performance of Thermo Scientific Vanquish DAD and MWD series detectors, outlining the design principles, operational capabilities, and application flexibility of the HL, FG, CG diode array detectors and the CG multiple wavelength detector from the Vanquish platform
Applied Methodology and Instrumentation
The Vanquish DADs and MWDs employ a single-beam reverse-optics layout with concave holographic gratings and achromatic lenses focusing light onto a 1024 element photodiode array. The primary light sources include deuterium lamps for UV range detection and tungsten lamps for VIS range extension. Optical parameters such as slit width can be adjusted from 1 to 8 nm, and internal calibration uses the D-alpha line; validation relies on a holmium oxide filter. Data acquisition rates reach up to 250 Hz for 3D spectra and up to 200 Hz for scanning. System health is monitored through power-up diagnostics, leak detection and predictive maintenance features integrated with Chromeleon CDS software GLP functions
Použitá instrumentace
- Vanquish Diode Array Detector HL, FG and CG models
- Vanquish Multiple Wavelength Detector CG
- LightPipe flow cells: standard (2 µL, 10 mm) and high sensitivity (13 µL, 60 mm)
- Biocompatible and standard flow cells for FG and CG models with pressure limits up to 120 bar
- Deuterium and tungsten lamps, diagnostic and flushing kits, back-flush and overpressure relief accessories
Main Results and Discussion
- Wavelength range from 190 to 800 nm with pixel resolution down to 0.5 nm and optical resolution of 1 nm FWHM
- Low noise levels (<±3 µAU at 230 nm) and baseline drift (<0.5 mAU/h) ensure reliable trace detection
- Excellent linearity (<5% deviation at 2.0 AU) and wide dynamic range facilitate quantitation of main and minor components
- Fast data collection (up to 250 Hz) and multiple signal channels (up to 10 channels plus 3D field) support ultrafast separations
- Robust construction with PEEK, fused silica, titanium and MP35N wetted parts ensures chemical compatibility and pressure tolerance
Benefits and Practical Applications
- Enhanced productivity through rapid, reproducible analyses and minimal method development
- Seamless integration with LC-MS and other hyphenated techniques using low-dispersion flow cells
- Flexible configuration for high-throughput screening, method transfer and routine quality control
- Predictive maintenance reduces downtime and optimizes service intervals based on actual usage
Future Trends and Opportunities
Advancements in miniaturized detectors, extended wavelength coverage into the UV-VIS-NIR regions and real-time chemometric analysis are expected to drive next-generation chromatographic detection. Integration with artificial intelligence for automated data interpretation and remote system monitoring will further streamline laboratory workflows
Conclusion
Thermo Scientific Vanquish DAD and MWD detectors combine precision optics, robust engineering and intelligent diagnostics to deliver high sensitivity, linearity and flexibility across diverse liquid chromatography applications. Their modular design and predictive maintenance features ensure long-term performance and minimal downtime for quality-critical analyses
Reference
Thermo Fisher Scientific Inc. Product Specification PS73047-EN
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific Vanquish—Diode Array Detector FG - PRODUCT SPECIFICATIONS
2018|Thermo Fisher Scientific|Brochures and specifications
PRODUCT SPECIFICATIONS Thermo Scientific Vanquish—Diode Array Detector FG Separate your productivity from the status quo Vanquish platform benefits • Unsurpassed retention time and peak area precision • High detector sensitivity and low baseline noise • Less maintenance and easy set-up…
Key words
vanquish, vanquishdiode, diodewavelength, wavelengtharray, arraycells, cellsdetector, detectornoise, noiseleak, leakperformance, performancethermo, thermoscientific, scientificoffs, offsquo, quoflexibility, flexibilityflow
Thermo Scientific Vanquish Variable Wavelength Detectors - PRODUCT SPECIFICATIONS
2021|Thermo Fisher Scientific|Brochures and specifications
PRODUCT SPECIFICATIONS Vanquish Variable Wavelength Detectors The collective power of chromatography LC that takes your productivity to new heights Vanquish platform benefits High-performance UV-Vis detection • Precision and reproducibility to meet every application demand Thermo Scientific™ Vanquish™ Variable Wavelength Detectors…
Key words
lamp, lampwavelength, wavelengthdeuterium, deuteriumvanquish, vanquishtungsten, tungstenvariable, variablechannel, channelnoise, noisevis, visdetector, detectorvwds, vwdslinearity, linearitychannels, channelspartnumber, partnumberdrift
Thermo Scientific Vanquish – Diode Array Detector HL - Product Specifications
2016|Thermo Fisher Scientific|Brochures and specifications
CHROM ATOGR APHY Better separations, more results, easier interaction Product Specif ications Thermo Scientific Vanquish – Diode Array Detector HL Thermo Scientific™ Vanquish™ UHPLC system is designed to offer: • Better separations with the power of the system to unveil…
Key words
vanquish, vanquishlightpipe, lightpipewavelength, wavelengthdiode, diodedeuterium, deuteriumarray, arrayications, icationsspecif, speciflamp, lampdad, daddetector, detectorholmium, holmiumdrift, driftvalidation, validationbest
Thermo Scientific UltiMate 3000 Variable Wavelength Detectors
2010|Thermo Fisher Scientific|Brochures and specifications
detectors UltiMate 3000 Variable Wavelength Detectors Dionex products are UHPLC compatible by design, establishing the new standard in conventional LC. Integrating hardware, software, and separation chemistry, Dionex offers UHPLC to everyone—for all needs. The VWD-3000 is a variable wavelength detector…
Key words
mau, maulamp, lampflow, flowpeek, peekdetector, detectorcells, cellscell, cellminutes, minutessuperior, superiorwavelength, wavelengthfused, fusedrange, rangelamps, lampswear, wearchromeleon