Selection of Column Length and Particle Size for High Resolution, Fast LC and LC/MS
Posters | 2010 | Thermo Fisher Scientific | PittconInstrumentation
Column geometry and particle size directly affect separation performance, analysis speed and system pressure in liquid chromatography. Optimizing these parameters is critical for high‐resolution, rapid separations in modern HPLC and LC‐MS workflows.
This study evaluates performance differences between columns packed with 1.9, 2.4 and 5 µm particles, focusing on separation efficiency, resolution, run time and backpressure. The aim is to define optimal combinations of particle size, column length and flow conditions for fast, robust analyses on conventional and high‐pressure systems.
Used Instrumentation:
Advances in column hardware will support wider adoption of sub-2 µm particles under high-pressure conditions. Integration with UHPLC and high-resolution mass spectrometry will further enhance sensitivity and throughput. Emerging materials and monolithic supports may offer alternative paths to high efficiency with lower pressure demands.
Optimizing particle size and column length allows fine tuning of separation efficiency, analysis speed and system backpressure. Small particle columns (1.9 and 2.4 µm) deliver high performance but require pressure management. Short columns packed with these particles provide a practical compromise for high-resolution, fast LC applications on standard HPLC platforms.
No formal literature list provided; study based on Thermo Fisher Scientific application data.
Consumables, HPLC, LC columns
IndustriesManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
Column geometry and particle size directly affect separation performance, analysis speed and system pressure in liquid chromatography. Optimizing these parameters is critical for high‐resolution, rapid separations in modern HPLC and LC‐MS workflows.
Objectives and Overview
This study evaluates performance differences between columns packed with 1.9, 2.4 and 5 µm particles, focusing on separation efficiency, resolution, run time and backpressure. The aim is to define optimal combinations of particle size, column length and flow conditions for fast, robust analyses on conventional and high‐pressure systems.
Methodology and Instrumentation
Used Instrumentation:
- Thermo Scientific Accela 600 HPLC system
- UV detection at 254 nm
- Hypersil GOLD 5 µm, 2.4 µm, 1.9 µm; lengths 50, 100, 150 × 2.1 mm
- Mobile phase: H₂O/ACN 50:50, 30 °C
- Flow rates varied, injection 1 µL
- Analytes: theophylline, p-nitroaniline, methyl benzoate, phenetole, o-xylene
- Mobile phase: H₂O/ACN 50:50 + 0.1% formic acid, 30 °C
- Flow rates varied, injection 1 µL
- Analytes: methyl, ethyl, propyl, butyl paraben
Main Results and Discussion
- Efficiency vs Flow Rate: Columns with 1.9 µm particles achieved the highest plate counts per meter across flow rates, outperforming 2.4 and 5 µm columns.
- Backpressure vs Flow Rate: Smaller particles induced substantially greater backpressure, consistent with the inverse square relationship between particle size and pressure.
- Efficiency vs Pressure: At a given backpressure, 1.9 µm columns delivered superior efficiency, enabling faster analyses without sacrificing resolution.
- Impact of Column Length: Longer columns (150 mm) improved resolution but increased run time and pressure; shorter columns (50 mm) delivered rapid separations with moderate resolution suitable for high‐throughput applications.
- Plate Count vs Column Length: Plate number scaled linearly with column length, with 2.4 µm columns offering a balance between efficiency and pressure.
- Chromatographic Performance: Comparative chromatograms showed sharper peaks and shorter run times for smaller particle sizes at constant flow, illustrating practical gains in speed and resolution.
Benefits and Practical Applications
- Enhanced Throughput: Small particle columns accelerate analyses, enabling higher sample throughput in pharmaceutical, environmental and food testing laboratories.
- Improved Resolution: 1.9 and 2.4 µm particles achieve superior peak separation, benefiting complex mixture analysis and trace compound detection.
- Pressure Management: Shorter columns packed with sub-2 µm particles can be used on conventional HPLC systems without exceeding pressure limits.
Future Trends and Potential Applications
Advances in column hardware will support wider adoption of sub-2 µm particles under high-pressure conditions. Integration with UHPLC and high-resolution mass spectrometry will further enhance sensitivity and throughput. Emerging materials and monolithic supports may offer alternative paths to high efficiency with lower pressure demands.
Conclusion
Optimizing particle size and column length allows fine tuning of separation efficiency, analysis speed and system backpressure. Small particle columns (1.9 and 2.4 µm) deliver high performance but require pressure management. Short columns packed with these particles provide a practical compromise for high-resolution, fast LC applications on standard HPLC platforms.
References
No formal literature list provided; study based on Thermo Fisher Scientific application data.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
LC columns and accessories
2020|Thermo Fisher Scientific|Brochures and specifications
1.5 1.0 0.5 LC columns and accessories Technical resources document Contents LC column selection 03 HPLC column selection by United States Pharmacopeia specifications 08 HPLC phases 12 HPLC column selection by manufacturer 14 Principles of fast LC 19 LC technical…
Key words
hypersil, hypersilgold, goldphenyl, phenylyes, yesaccucore, accucoresyncronis, syncronisymc, ymcsilica, silicaphenomenex, phenomenexmacherey, machereynagel, nagelwaters, waterscolumn, columnthermo, thermohilic
Thermo Solid Core Technical Compendium
2012|Thermo Fisher Scientific|Guides
150-C4 PFP Solid Core 150-C18 Phenyl-Hexyl 150-Amide-HILIC Phenyl-X HILIC XL-C8 C18 aQ C30 XL-C18 Urea-HILIC Polar Premium RP-MS Technical Compendium C8 Want fast, high-resolution separations, plus a range of conventional and unique selectivities to meet all your needs? Thermo Scientific™…
Key words
accucore, accucorecolumns, columnscore, corecolumn, columnefficiency, efficiencyparticle, particlephase, phaseimpedance, impedancehplc, hplcpressure, pressurehbc, hbcmobile, mobileporous, poroussolid, solidchromatographic
2019/2021 Chromatography Consumables Catalog - Bio LC columns and accessories
2019|Thermo Fisher Scientific|Others
Connected chromatography solutions 2019/2021 Chromatography Consumables Catalog The collective power of chromatography Expect reproducible results with sample prep, columns and vials Maximizing your chromatography productivity and achieving reproducible results requires optimizing the whole workflow from sample to knowledge. By choosing…
Key words
columns, columnsmabpac, mabpacsize, sizelength, lengthcolumn, columnparticle, particlebiolc, biolcproswift, proswiftpropac, propacprotein, proteinvariants, variantsexchange, exchangeresolution, resolutionbiobasic, biobasicaccessories
2019/2021 Chromatography Consumables Catalog - LC columns and accessories
2019|Thermo Fisher Scientific|Others
Connected chromatography solutions 2019/2021 Chromatography Consumables Catalog The collective power of chromatography Expect reproducible results with sample prep, columns and vials Maximizing your chromatography productivity and achieving reproducible results requires optimizing the whole workflow from sample to knowledge. By choosing…
Key words
hypersil, hypersilhplc, hplcguard, guardcolumns, columnscolumn, columnformat, formatsize, sizequantity, quantitylength, lengthaccucore, accucoreparticle, particlehydrophobicity, hydrophobicitydrop, dropaccessories, accessoriesacclaim