Turnkey, Multi-pathway Signaling Analysis Using a Synthetic Phosphopeptide Panel, Standardized Sample Preparation Kits and SureQuant Internal Standard Targeted Quantitation
Posters | 2020 | Thermo Fisher Scientific | ASMSInstrumentation
Quantitative analysis of protein phosphorylation is pivotal for understanding cellular signaling networks and disease mechanisms. Traditional phosphoproteomics workflows often suffer from low enrichment specificity and inconsistent detection of low-abundance sites. A robust, targeted approach for reliable absolute quantification of key phosphorylation events can advance research in basic biology, drug development, and clinical diagnostics.
This study aimed to develop a turnkey, high-density workflow for multi-pathway phosphopeptide quantitation. The method integrates Sequential Metal Oxide Affinity Chromatography (SMOAC) for enrichment, a panel of 138 heavy-isotope-labeled phosphopeptide standards, and SureQuant internal standard (IS)-triggered acquisition on an Orbitrap Exploris 480 mass spectrometer. Performance was benchmarked against data-dependent acquisition (DDA) and parallel reaction monitoring (PRM) for detection sensitivity and reproducibility.
Sample Preparation and Enrichment:
SMOAC enrichment yielded over 6 500 phosphopeptide identifications by DDA; however, only 10 endogenous peptides from the multi-pathway panel were detected. PRM improved detection to 33 endogenous targets. SureQuant delivered the best performance, identifying 131 endogenous phosphopeptides with dynamic MS2 fill times ~6× longer than PRM. Real-time IS recognition and triggered acquisition enabled high sensitivity while maintaining adequate peak sampling density.
The combined SMOAC and SureQuant workflow provides:
Advancements may include automation of SMOAC protocols, expansion to broader post-translational modification panels, integration with clinical biomarker validation workflows, and AI-driven data analysis to accelerate biological insights and therapeutic development.
The SureQuant IS-triggered, SMOAC-based workflow significantly outperforms traditional DDA and PRM in detecting and quantifying multi-pathway phosphorylation events. Standardized sample preparation, dynamic acquisition, and use of reference standards yield a robust platform for targeted phosphoproteomics.
Gajadhar AS, Patel B, Jensen P, Gallien S, Huguet R, Opperman K, Rogers JC, Huhmer A, Lopez-Ferrer D. Turnkey, Multi-pathway Signaling Analysis Using a Synthetic Phosphopeptide Panel, Standardized Sample Preparation Kits and SureQuant Internal Standard Targeted Quantitation. Thermo Fisher Scientific. 2020.
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
IndustriesProteomics
ManufacturerThermo Fisher Scientific
Summary
Significance of the Topic
Quantitative analysis of protein phosphorylation is pivotal for understanding cellular signaling networks and disease mechanisms. Traditional phosphoproteomics workflows often suffer from low enrichment specificity and inconsistent detection of low-abundance sites. A robust, targeted approach for reliable absolute quantification of key phosphorylation events can advance research in basic biology, drug development, and clinical diagnostics.
Study Objectives and Overview
This study aimed to develop a turnkey, high-density workflow for multi-pathway phosphopeptide quantitation. The method integrates Sequential Metal Oxide Affinity Chromatography (SMOAC) for enrichment, a panel of 138 heavy-isotope-labeled phosphopeptide standards, and SureQuant internal standard (IS)-triggered acquisition on an Orbitrap Exploris 480 mass spectrometer. Performance was benchmarked against data-dependent acquisition (DDA) and parallel reaction monitoring (PRM) for detection sensitivity and reproducibility.
Methodology and Instrumentation
Sample Preparation and Enrichment:
- HeLa S3 cells treated with nocodazole to induce mitotic arrest.
- Protein digestion using EasyPep Maxi kit; spiked with 1 pmol of each heavy phosphopeptide standard per mg digest.
- Sequential enrichment by TiO2 and Fe-NTA kits (SMOAC) followed by desalting with Pierce spin columns.
- Chromatography on EASY-Spray C18 columns (2.4–34% ACN gradient over 60 min, 300 nL/min) using EASY-nLC 1200.
- Orbitrap Exploris 480 MS with two-step SureQuant workflow: a survey run to define optimal precursor and fragment parameters, followed by dynamic, IS-triggered high-sensitivity MS2 scans.
- DDA data processed in Proteome Discoverer 2.2 with SEQUEST HT (10 ppm precursor, 0.02 Da fragment tolerance).
- PRM and SureQuant quantitation performed in Skyline, measuring light/heavy ratios and leveraging dynamic fill-time control.
Main Results and Discussion
SMOAC enrichment yielded over 6 500 phosphopeptide identifications by DDA; however, only 10 endogenous peptides from the multi-pathway panel were detected. PRM improved detection to 33 endogenous targets. SureQuant delivered the best performance, identifying 131 endogenous phosphopeptides with dynamic MS2 fill times ~6× longer than PRM. Real-time IS recognition and triggered acquisition enabled high sensitivity while maintaining adequate peak sampling density.
Benefits and Practical Applications
The combined SMOAC and SureQuant workflow provides:
- High reproducibility and sensitivity for low-abundance phosphorylation sites across multiple signaling pathways (EGFR/HER, RAS-MAPK, PI3K/AKT/mTOR, AMPK, apoptosis, stress).
- Turnkey applicability for routine phosphoproteomics in research and quality control laboratories.
- Absolute quantitation capability leveraging heavy-isotope standards.
Future Trends and Potential Applications
Advancements may include automation of SMOAC protocols, expansion to broader post-translational modification panels, integration with clinical biomarker validation workflows, and AI-driven data analysis to accelerate biological insights and therapeutic development.
Conclusion
The SureQuant IS-triggered, SMOAC-based workflow significantly outperforms traditional DDA and PRM in detecting and quantifying multi-pathway phosphorylation events. Standardized sample preparation, dynamic acquisition, and use of reference standards yield a robust platform for targeted phosphoproteomics.
Reference
Gajadhar AS, Patel B, Jensen P, Gallien S, Huguet R, Opperman K, Rogers JC, Huhmer A, Lopez-Ferrer D. Turnkey, Multi-pathway Signaling Analysis Using a Synthetic Phosphopeptide Panel, Standardized Sample Preparation Kits and SureQuant Internal Standard Targeted Quantitation. Thermo Fisher Scientific. 2020.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
SureQuant Targeted Mass Spectrometry Standards and Assay Panel for Quantitative Analysis of Phosphorylated Proteins from Multiple Signaling Pathways
2021|Thermo Fisher Scientific|Posters
SureQuant Targeted Mass Spectrometry Standards and Assay Panel for Quantitative Analysis of Phosphorylated Proteins from Multiple Signaling Pathways Bhavin Patel1, Penny Jensen1, Amirmansoor Hakimi2, Sebastien Gallien3,4, Aaron Gajadhar2, Ana Martinez Del Val5, Jesper Olsen5, Andreas Huhmer2, Daniel Lopez-Ferrer2, Ryan Bomgarden1,…
Key words
phosphopeptide, phosphopeptidesignaling, signalingphosphorylated, phosphorylatedsurequant, surequantnta, ntapathways, pathwaysenrichment, enrichmentprm, prmmultipathway, multipathwayphosphosites, phosphositesmagnetic, magneticphosphopeptides, phosphopeptidesphosphorylation, phosphorylationskyline, skylinebead
SureQuant Targeted Mass Spectrometry Standards and Assay Panel for Quantitative Analysis of Phosphorylated Proteins from Multiple Signaling Pathways 
2021|Thermo Fisher Scientific|Posters
SureQuant Targeted Mass Spectrometry Standards and Assay Panel for Quantitative Analysis of Phosphorylated Proteins from Multiple Signaling Pathways Bhavin Patel1, Penny Jensen1, Amirmansoor Hakimi2, Sebastien Gallien3,4, Aaron Gajadhar2, Ana Martinez Del Val5, Jesper Olsen5, Andreas Huhmer2, Daniel Lopez-Ferrer2, Ryan Bomgarden1,…
Key words
phosphopeptide, phosphopeptidesignaling, signalingphosphorylated, phosphorylatedsurequant, surequantnta, ntapathways, pathwaysenrichment, enrichmentmultipathway, multipathwayprm, prmphosphosites, phosphositesmagnetic, magneticphosphopeptides, phosphopeptidesphosphorylation, phosphorylationskyline, skylinebead
Quantitative, comprehensive multi-pathway signaling analysis using an optimized phosphopeptide enrichment method combined with an internal standard triggered targeted MS assay
2019|Thermo Fisher Scientific|Posters
Quantitative, comprehensive multi-pathway signaling analysis using an optimized phosphopeptide enrichment method combined with an internal standard triggered targeted MS assay Bhavin Patel1; Penny Jensen1; Aaron S. Gajadhar2; Sebastien Gallien3; Jae Choi1; Romain Huguet2; Graeme McAlister2; Derek Bailey2; Shannon Eliuk2; Markus…
Key words
phosphopeptide, phosphopeptidesignaling, signalingsurequant, surequanthela, helaphosphopeptides, phosphopeptideshegf, hegfsmoac, smoacpathway, pathwayegf, egfenrichment, enrichmentheavy, heavysmaoc, smaocpeptides, peptideshiselecttm, hiselecttmenriched
Quantitative, comprehensive multi-pathway signaling analysis using an optimized phosphopeptide enrichment method combined with an internal standard triggered targeted MS assay
2019|Thermo Fisher Scientific|Posters
Quantitative, comprehensive multi-pathway signaling analysis using an optimized phosphopeptide enrichment method combined with an internal standard triggered targeted MS assay Bhavin Patel1; Penny Jensen1; Aaron S. Gajadhar2; Sebastien Gallien3; Jae Choi1; Romain Huguet2; Graeme McAlister2; Derek Bailey2; Shannon Eliuk2; Markus…
Key words
phosphopeptide, phosphopeptidesurequant, surequanthela, helasignaling, signalingphosphopeptides, phosphopeptideshegf, hegfsmoac, smoacegf, egfheavy, heavysmaoc, smaocenrichment, enrichmenthiselecttm, hiselecttmenriched, enrichedpeptides, peptidespathway