Ion Chromatography Coupled with Mass Spectrometry for Metabolomics
Technical notes | 2011 | Thermo Fisher ScientificInstrumentation
The analysis of small polar and ionic metabolites is crucial for metabolomics as traditional reversed-phase methods often fail to separate or retain these compounds. Ion chromatography (IC) coupled with mass spectrometry (MS) overcomes these limitations by using on-line eluent suppression to convert high-salt eluents into MS-compatible water, enabling sensitive detection of organic acids, carbohydrates, nucleotides, and amino acids.
This work aims to integrate anion-exchange IC with continuous on-line desalting and high-resolution MS to provide a robust platform for comprehensive metabolite profiling. The study evaluates the separation performance, MS compatibility, and metabolite coverage achievable with this IC-MS approach.
The IC-MS system achieved effective separation of diverse polar metabolites, including organic and aromatic acids, phosphorylated species, sugars, nucleosides, and sulfonated compounds. Comparative studies showed that combining IC with reversed-phase and hydrophilic interaction chromatography significantly increases metabolite coverage. In Trypanosoma brucei extracts, IC-MS alone identified 24 of 80 pathway intermediates, enhancing pathway analysis and biomarker discovery.
Expanding the approach to cation-exchange IC for amine-containing metabolites will further increase coverage. Advances in capillary IC, higher-resolution MS, and integrated data-processing tools will drive deeper insights into the metabolome. Combining multiple orthogonal separations will remain key to comprehensive metabolomic studies.
On-line desalting IC-MS presents a powerful, versatile platform for the separation and identification of small polar and ionic metabolites in complex matrices, enhancing sensitivity, selectivity, and metabolite coverage beyond traditional LC-MS approaches.
IC-MS
IndustriesMetabolomics
ManufacturerThermo Fisher Scientific
Summary
Importance of Topic
The analysis of small polar and ionic metabolites is crucial for metabolomics as traditional reversed-phase methods often fail to separate or retain these compounds. Ion chromatography (IC) coupled with mass spectrometry (MS) overcomes these limitations by using on-line eluent suppression to convert high-salt eluents into MS-compatible water, enabling sensitive detection of organic acids, carbohydrates, nucleotides, and amino acids.
Objectives and Study Overview
This work aims to integrate anion-exchange IC with continuous on-line desalting and high-resolution MS to provide a robust platform for comprehensive metabolite profiling. The study evaluates the separation performance, MS compatibility, and metabolite coverage achievable with this IC-MS approach.
Methodology and Instrumentation
- Anion-exchange separation using a Thermo Scientific Dionex IonPac AS11 column with a KOH gradient generated electrolytically
- Continuous on-line desalting via an electrolytic suppressor converting KOH to pure water, monitored by conductivity below 1.0 µS·cm−1
- Use of a PEEK-based pump for ultrapure water delivery to the eluent generator
- Detection and identification with a high-resolution electrospray ionization mass spectrometer, optionally with organic solvent makeup flow
Key Findings and Discussion
The IC-MS system achieved effective separation of diverse polar metabolites, including organic and aromatic acids, phosphorylated species, sugars, nucleosides, and sulfonated compounds. Comparative studies showed that combining IC with reversed-phase and hydrophilic interaction chromatography significantly increases metabolite coverage. In Trypanosoma brucei extracts, IC-MS alone identified 24 of 80 pathway intermediates, enhancing pathway analysis and biomarker discovery.
Benefits and Practical Applications
- Enhanced separation of ionic and polar metabolites not amenable to reversed-phase LC
- Direct coupling to MS for high sensitivity and additional structural information
- Orthogonal separation complements reversed-phase and HILIC methods to broaden metabolic profiling
- Applications in biological pathway analysis, biomarker discovery, environmental monitoring, and QA/QC of beverages and water pollutants
Future Trends and Opportunities
Expanding the approach to cation-exchange IC for amine-containing metabolites will further increase coverage. Advances in capillary IC, higher-resolution MS, and integrated data-processing tools will drive deeper insights into the metabolome. Combining multiple orthogonal separations will remain key to comprehensive metabolomic studies.
Conclusion
On-line desalting IC-MS presents a powerful, versatile platform for the separation and identification of small polar and ionic metabolites in complex matrices, enhancing sensitivity, selectivity, and metabolite coverage beyond traditional LC-MS approaches.
Reference
- Small H, Stevens TS, Bauman WC. Anal Chem. 1975;47:1801.
- DeBorba B, Rohrer JS. J Chromatogr A. 2007;1155:22–30.
- Lyubarskaya Y, et al. Anal Biochem. 2006;348:24–39.
- Thayer JR, et al. Anal Biochem. 2007;361:132–139.
- Weiss J. Ion Chromatography. VCH; 1995.
- Wang LJ, Schunte WA. LC-GC. 2009;Sep:2.
- Mohsin SB. J Chromatogr A. 2000;884:23–30.
- Bauer KH, et al. J Chromatogr A. 1999;837:117–128.
- Bruggink C, Maurer R, Herrmann H, et al. J Chromatogr A. 2005;1085:104–109.
- Saccani G, et al. J Chromatogr A. 2005;1082:43–50.
- Gika HG, Theodoridis GA, Wilson ID. J Sep Sci. 2008;31:1598–1608.
- Daviss B. The Scientist. 2005;19(8):25–28.
- Lindon JC, et al. Biomarkers. 2004;9(1):1–31.
- Bruggink C, Wuhrer M, Koeleman CAM, et al. J Chromatogr B. 2005;829:136–143.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Ion Chromatography Coupled with Mass Spectrometry for Metabolomics
2011|Thermo Fisher Scientific|Applications
Ion Chromatography Coupled with Mass Spectrometry for Metabolomics CAN 108 Karl Burgess Functional Genomics, Joesef Black building, Glasgow University, Glasgow, UK Introduction The fields of metabolomics and metabonomics attempt to phenotype and quantify the vast array of metabolites present in…
Key words
exchange, exchangemetabolites, metabolitesmetabolomics, metabolomicspathways, pathwayseluent, eluention, ionbiological, biologicalmetabolic, metabolicsuppressor, suppressorseparation, separationintermediates, intermediatesmetabonomics, metabonomicssuppression, suppressioncoverage, coveragedesalting
Untargeted Metabolic Profiling of Oral Cancer Cells Using Capillary Ion Chromatography Coupled with an Orbitrap Mass Spectrometer
2016|Thermo Fisher Scientific|Applications
Terri Christison1 and Junhua Wang2 Thermo Fisher Scientific, Sunnyvale, CA 2 Thermo Fisher Scientific, San Jose, CA 1 Appli cat i on N ote 1 1 3 7 Untargeted Metabolic Profiling of Oral Cancer Cells Using Capillary Ion Chromatography Coupled…
Key words
capillary, capillarycancer, canceroral, oralmetabolites, metaboliteshram, hramwere, wereneck, neckmetabolite, metaboliteaconitate, aconitateexactive, exactiveeluent, eluentmass, massmonophosphate, monophosphateuhplc, uhplchilic
Targeted metabolomics method using IC Orbitrap with high resolution mass spectrometry
2020|Thermo Fisher Scientific|Applications
CUSTOMER APPLICATION NOTE 73265 Targeted metabolomics method using IC Orbitrap with high resolution mass spectrometry Authors: Yoshihiro Izumi, Takeshi Bamba, Medical Institute of Bioregulation, Kyushu University, Research Center for Transomics Medicine, Division of Metabolomics Keywords: Anionic compound, samplepretreatment, ion chromatography,…
Key words
exactive, exactivemetabolites, metabolitesnegative, negativeion, ionsuppressor, suppressorapproach, approachpotassium, potassiummeasurement, measurementsystem, systemphosphate, phosphatecamp, campmass, masseluent, eluentpolar, polarabundance
Pathway-Targeted Metabolomic Analysis in Oral/Head and Neck Cancer Cells Using Ion Chromatography-Mass Spectrometry
2016|Thermo Fisher Scientific|Applications
Junhua Wang1, Terri Christison1, Krista Backiel2, Grace Ji3, Shen Hu3, Linda Lopez1, Yingying Huang1, Andreas Huhmer1. 1Thermo Fisher Scientific Inc., San Jose, CA; 2Cambridge Isotope Laboratories Inc., Tewksbury, MA; 3 School of Dentistry and Jonsson Comprehensive Cancer Center, UCLA, Los…
Key words
tca, tcatargeted, targetedcancer, cancermetabolites, metabolitesendogenous, endogenouscells, cellsisotope, isotopemetabolomics, metabolomicsnontargeted, nontargetedstable, stablecycle, cyclestandards, standardspyruvate, pyruvatecapic, capicmetabolic